1.13 Information
Brine/heating
The supply and return temperatures, the temperature difference, the actual
pressure and the adjustment percentage rate of the circulation pumps in the
brine and heat production chain are displayed.
Outdoor temperature
The actual outdoor temperature is displayed.
Room terminals
In installations with bus-connected room terminals (Th-T or TH sensors), the
preset room temperature (setting value), actual temperature (T-real) and actual
relative humidity (RH) of the terminal assigned to each supply group are
displayed.
Heating buffer tank / cooling buffer tank
The default temperature, the difference between the starting temperatures and
the actual temperature of the buffer tank are displayed.
Heating and cooling buffer tanks both have own menu window.
Heating groups / Cooling groups
For each supply group, the preset supply temperature, the actual supply
temperature and the adjustment percentage rate (Reg) are displayed.
Both the heating and cooling supply group have their own menu window.
Hot water tank
The default temperature, the difference between the starting temperatures
and the actual temperature of the buffer tank are displayed.
Actual measuring value / monthly measuring value / yearly measuring value
These menu windows contain information on heat pump consumption,
capacity, input energy and energy output.
The menu windows contain information about current, monthly and annual
values.
Active demand
Actual demand for starting the compressor is displayed in the upper area.
The bottom area shows the demand that the heat pump receives to start the
different supply groups.
The fact that there is an active demand for a compressor or supply groups
does not necessarily mean that they must be in operation. There may be other
reasons that prevent their start.