5 Maintenance
Zehnder recommends you to get a maintenance
contract with an expert company. Some installers
provide a maintenance contract in which the user
maintenance can be integrated. Contact the supplier
of the unit for a list of registered installers nearby.
Do not disconnect the power of the unit, unless
told otherwise in the manual of the unit. This
can lead to a build-up of moisture and result in
problems with mould.
Do the maintenance tasks within the given
periods. If not, the performance of the ventilation
system will decrease.
Part of system
Limit
Responsible
Procedure
Filters
6 months
User
Replace the filters
Valves
6 months
User
Clean the valves
Grilles
6 months
User
Clean the grilles
Operating device
6 months
User
Clean the operating device
Condensation drain
6 months
User
Fill the condensation drain
System inspection and cleaning
4 years
Installer or service engineer
-
5.1 Replace the filters
When indicated you must replace the filters. The
indication methods that follow are available:
�
The LED light on the unit flashes;
�
The display on the unit shows the warning
message: CHANGE FILTERS NOW;
�
The operating device can show a message.
The manual of the operating device contains
more information about the indication on filter
replacement.
Replace the filters at least every six months. This
will insure a comfortable and healthy air quality
and will protect the unit from pollution.
When you need to replace the filters:
1. Order new filters.
Contact the installer of the unit for providing the
correct filters or order online at www.epicair.
co.uk.
Filter set
Order number
G4/G4 (1x/1x)
400502012
F78/G4 (1x/1x)
400502013
The warranty becomes invalid if:
�
Parts are used that have not been supplied by
the manufacturer;
�
The unit is used without filters.
2. When the new filters have arrived open the visor.
3. Select NOW on the warning message. For safety
reasons the unit will stop the ventilation during the
filter replacement instructions.
4. Follow all the instructions on the display.
Item
Description
Remove filter caps.
Remove old filters.
Insert supply filter.
Insert extract filter.
Insert filter caps
- Select NEXT to go forward after every
completed instruction.
- Select BACK to go back to the previous
instruction.
5. Select CONFIRM to close the filter replacement
instructions and start up the ventilation again.
6. Close the visor.
To postpone the filter replacement for one day,
select IGNORE on the warning message. If you are
ready to start filter replacement before the filter
warning re-appears, navigate to CHANGE FILTERS in
the FILTERS menu.
8 Standard available on the unit with pre-heater.