3.2.3 STATUS (read only)
Menu item
Function
CURRENT ERRORS
To view the codes of the current errors.
UNIT
To view the information about the unit.
�
HRU TYPE: view the type name of the unit;
�
FIRMWARE VERSION: view the firmware version of the unit;
�
SERIAL NUMBER: view the serial number of the main board in the unit.
SCHEDULER
To view the scheduler step in which the unit is currently running.
�
VENTILATION: view which step of the ventilation scheduler is in operation;
�
COMFOCOOL3: view which step of the ComfoCool Q600 scheduler is in operation.
TEMP. AND HUMIDITY
To view the current temperature and humidity of the airflows.
�
EXTRACT AIR TEMP.: view the current temperature of the extract airflow;
�
EXTRACT AIR HUM.: view the current humidity level of the extract airflow;
�
EXHAUST AIR TEMP.: view the current temperature of the exhaust airflow;
�
EXHAUST AIR HUM.: view the current humidity level of the exhaust airflow;
�
OUTDOOR AIR TEMP.: view the current temperature of the outdoor airflow;
�
OUTDOOR AIR HUM.: view the current humidity level of the outdoor airflow;
�
SUPPLY AIR TEMP.: view the current temperature of the supply airflow;
�
SUPPLY AIR HUM.: view the current humidity level of the supply airflow.
BYPASS STATE
To view the current state of the heat recovery control (bypass).
�
The percentage of bypassed air is shown.
FROST UNBALANCE
To view the current state of airflow unbalance caused by the frost protection function.
�
The percentage of supply air reduction is shown.
FROST PREHEATER3
To view the current state of the preheater caused by the frost protection function.
�
The current power of the preheater is shown.
POSTHEATER3
To view the current state of the post-heater.
�
The percentage of the post-heater control is shown.
ANALOG INPUT3
To view the current state of the analog input(s)
�
0-10V 13: view the voltage level of the first analog input.
�
0-10V 23: view the voltage level of the second analog input.
�
0-10V 33: view the voltage level of the third analog input.
�
0-10V 43: view the voltage level of the fourth analog input.
SUBSOIL HEAT EXCH.3
To view the current state of the regulated subsoil heat exchanger (e.g. ComfoFond-L Q).
�
STATE: view the current state of the regulated subsoil heat exchanger pump;
�
OUTDOOR AIR TEMP.: view the current outdoor air temperature;
�
GROUND TEMPERATURE: view the current temperature of the regulated subsoil heat exchanger
brine liquid.
COMFOCOOL3
To view the current state of the ComfoCool Q600.
�
STATE: view the current ComfoCool Q600 mode and the current ComfoCool Q600 supply air
temperature;
�
CONDENSER TEMP: view the current condenser temperature.
SEASON DETECTION
To view the current season detection state.
�
SEASON: view the current season mode;
�
LIMIT RMOT HEAT: view the set RMOT4 below which the (central) heating system is normally active;
�
LIMIT RMOT COOL: view the set RMOT4 above which the (central) cooling system is normally
active;
�
CURRENT RMOT: view the current RMOT4.
FANS
To view the current state of the fans
SUPPLY FAN
�
FAN SPEED: view the current speed of the fan.
�
FAN DUTY: view the current duty of the fan.
�
FLOW: view the current airflow of the fan.
EXTRACT FAN
�
FAN SPEED: view the current speed of the fan.
�
FAN DUTY: view the current duty of the fan.
�
FLOW: view the current airflow of the fan.
ENERGY
To view the energy consumption and saved energy.
POWER CONSUMPTION
�
VENTILATION: view the current electrical consumption of the fans.
�
PREHEATER: view the current electrical consumption of the preheater.
�
YEAR TO DATE: view the energy consumption of the fans since the beginning of the year.
�
TOTAL: view the total energy consumption of the fans since the moment of commissioning.
AVOIDED HEATING
�
ACTUAL POWER: view the current avoided heating power.
�
YEAR TO DATE: view the avoided heating energy since the beginning of the year.
�
TOTAL: view the avoided heating energy since the moment of commissioning.
AVOIDED COOLING
�
ACTUAL POWER: view the current avoided cooling power.
�
YEAR TO DATE: view the avoided cooling energy since the beginning of the year.
�
TOTAL: view the avoided cooling energy since the moment of commissioning. .
TOTAL SAVINGS
�
YEAR TO DATE: to view the total energy savings since the beginning of the year.
�
TOTAL: to view the total energy savings since the moment of commissioning.
3 This menu is only visible when the accessory is connected to the unit.
4 RMOT = running mean outdoor temperature (average temperature over past five days).