40005904
3.3 Status indicator LED
This LED (
3
) tells you the status of your radiator:
- Off: your device is in the heating stop position.
- On, green: the radiator is in operation, and the desired temperature has
been reached.
- On, red: the radiator is in operation, and the desired temperature has not
been reached.
- Flashing red: indicates a fault with your device.
3.4 Protection
Protective cover:
Your radiator is fitted with a removable transparent cover (
4
) which protects the
controls.
Locking the cover (screw may be supplied, depending on the model):
Certain special applications require the ability to prevent changes to the
settings. The cover can be locked using the screw supplied.
To do this, you must first drill a hole 3 millimetres in diameter in the transparent
cover, using the mark (
5
) as a guide.
Then replace the cover onto your box, ensuring that it is correctly positioned,
and screw in the screw so that it pierces the seal provided in the box; stop screwing
when the head of the screw comes into contact with the cover.
Ventilation inlets:
For the device to work properly, you must ensure that the control box ventilation
inlets (
6
) are never blocked (by dust build-up).
Commands received
Oscilloscopes
Ref./Neutral
Mode
obtained
Results obtained
No current
Comfort
The temperature obtained is that of
the thermostat setting.
Alternation
* no current : 4’57’’
* phase 230 V : 3’’
Comfort
-1°C
The temperature obtained is that of
the thermostat setting - 1°C
Alternation
* no current : 4’53’’
* phase 230 V : 7’’
Comfort
-2°C
The temperature obtained is that of
the thermostat setting - 2°C
Complete alternation 230 V
Eco
Economy temperature.
The temperature obtained is that of
the thermostat setting - 3.5°C
Negative semi-alternance
-115 V
Frost
protection
Frost protection temperature
of approx 7°C.
Can be used for load-shedding.
Positive semi-alternation
+ 115 V
Heating
stop
Immediate stopping of appliance.
4. Maintenance and troubleshooting
tips
4.1 Routine maintenance operations
NOTE:
Before carrying out any maintenance operation on your appliance, ensure
that it is switched off.
High-quality materials and surface treatment protect your radiator against
corrosion and impacts.
To maximise the service life of your radiator, we recommend you take the
following precautions:
- Never use abrasive or corrosive products on the outer surfaces of the appliance
(except the electrical parts); use warm, soapy water.
- Use a soft, dry cloth without any solvents to clean the control box.
4.2 Troubleshooting
Problem
Diagnosis
Steps to take
The radiator does not
work.
The radiator is not
powered.
Make sure the radiator is
correctly connected to the
electricity supply. Contact
your dealer if this is not the
case.
The radiator is in
NO HEAT mode.
Turn on the radiator.
The setpoint temperature
is below the room
temperature.
Increase the setpoint
temperature (COMFORT
mode).
The status indicator
LED flashes red.
Contact your dealer.