20
21
EN
EN
40005904
40005904
2.2 Positioning your appliance
To get the most out of your appliance and enjoy the highest standards of
comfort, we recommend that you install the appliance near places with high heat loss
(windows, doors, etc.) wherever possible.
You will find a complete set of assembly instructions in your appliance’s box.
IMPORTANT
Use wedges during installa-
tion to prevent the control unit from touching
the floor. (see figure
③
)
2.3 Connecting the appliance
The technical specifications of your radiator are shown on its nameplate.
Please note these down before installing it and before requesting any after-
sales assistance.
When connecting the appliance to the mains, you must observe:
• the voltage indicated on the nameplate;
• conventional colour coding:
– blue or grey: neutral
– brown: live
– black: pilot wire
IP: protection level of your appliance against the
ingress of solid foreign bodies and water spray
Voltage and power required for installation
Appliance reference number
Class II: double insulated
OF: serial number
Manufacturer code
ATTENTION NE PAS COUVRIR IP 34
ACOVA
XXXX–XXX–XXX
230V ~ XXXXW
OF: XXXXXXXXXX XXXXXX
N CONSTRUCTEUR XXXXXX
③
CONNECTING PRINCIPLE WITH PILOT WIRE:
Your appliance is equipped with a pilot wire for connection to a pilot wire
programming base unit (not supplied with the appliance).
NOTE:
Your appliance is equipped with an integrated electronic control system
so we cannot accept any liability should the appliance be used with pilot
wire programming base units that function by disconnecting the supply
voltage (refer to the instructions supplied with your control unit).
If your radiator stops receiving instructions from the pilot wire pro-
gramming base unit, when in AUTO mode it will operate in COMFORT
mode until a new mode command is received from the programming base
unit.
CONNECTING PRINCIPLE WITHOUT PILOT WIRE:
If the pilot wire is not connected, it must be insulated for safety reasons. Under
no circumstances must it be connected to earth.
N (blue or grey)
Neutral
Live
Pilot wire (base unit)
Live
Neutral
L (brown)
Pilot wire (black)
Pilot wire (black)
L (brown)
N (blue or grey)
Содержание ComfoAir 2200