3
EN - 20 - For the installer
3.4 Installation
conditions
In order to determine whether the ComfoAir can be
installed in a certain area, the following aspects must
be taken into account:
• The ComfoAir must be installed according to the
general and locally applicable safety and installa-
tion regulations of power and water companies,
as well as the instructions in this manual.
• The system must be fi tted to allow suffi cient room
around the ComfoAir for the air connections and
supply and exhaust ducts as well as for carrying
out maintenance activities.
• The room must offer the following provisions:
-
Air duct connections.
-
230V electrical connection.
-
Provisions for the condensation drain.
• The ComfoAir must be installed in a frost-free
space. The condensation must be drained off
frost-free, at a gradient and incorporate a 'U'
bend.
We do not recommend installing the Com-
foAir in areas with a higher average humidity
(such as bathroom or toilet). This will prevent
condensation on the outside of the ComfoAir.
• The cable used to connect the CC Ease panel
must have the following specifi cations:
-
Cable type: shielded twisted pair 4x0.34mm2.
-
Cable lengtth: 10 m maximum.
A 10mm gap should be left under the in-
side doors in order to ensure effective and
draught-free airfl ow in the house. If these
openings are obstructed, due to draught
excluders or deep-pile carpet, the airfl ow in
the house will stagnate. As a result, system
performance will be compromised or fail al-
together.
3.5 Installation of the ComfoAir
3.5.1 Transport and unpacking
Take the necessary precautions when transporting
and unpacking the ComfoAir.
Make sure the packing material is disposed
of in an environmentally friendly manner.
3.5.2 Checking the delivery
Contact your supplier immediately in case of damage
or an incomplete delivery. The delivery must include:
•
ComfoAir;
Check the identifi cation plate to ensure that it is
the required type;
•
Ceiling mounting set;
•
Wall mounting bracket;
•
Manual.
The ComfoAir is supplied in the following types:
Type
ComfoAir 200 L
ComfoAir 200 R
Type
ComfoAir 200 L Luxe ComfoAir 200 L Luxe PH
ComfoAir 200 R Luxe ComfoAir 200 R Luxe PH
Meaning of the suffi xes:
•
L =
Left.
•
R =
Right.
• PH = Pre-heater.
•
Luxe = Refers to the luxury version with the
connector PCB.
CC Ease panel (optional) can be ordered