background image

EN - II   

All rights reserved.
This manual has been compiled with the utmost care. The publisher cannot be held liable for any damage caused as a result of miss-
ing or incorrect information in this manual. In case of dis putes the Dutch version of these instructions will be binding.

Содержание ComfoAir 160

Страница 1: ...ComfoAir 160 User manual...

Страница 2: ...has been compiled with the utmost care The publisher cannot be held liable for any damage caused as a result of miss ing or incorrect information in this manual In case of disputes the Dutch version...

Страница 3: ...CO2 sensor 6 2 2 5 CC Ease panel 6 2 3 operating the CC Ease panel 7 2 3 1 Setting the date and time 7 2 3 2 Reading and setting the comfort temperature 7 2 3 3 Reading and setting the ventilation vo...

Страница 4: ...EN IV EN IV...

Страница 5: ...24 months after fitting up to a maximum of 30 months after the date of manufacture Warranty claims may only be submitted for material faults and or construction faults arising during the warranty per...

Страница 6: ...p this manual with the ComfoAir throughout its life Instructions with regard to cleaning or replacing the filters on the intake and exhaust valves must be care fully observed The specifications stated...

Страница 7: ...and outgoing air the ComfoAir also provides the benefits of heat recovery Heat recovery means that heat from the extracted air is transferred to the fresh and usually colder air from outside the build...

Страница 8: ...U comfort temperature Shown in display 1 A 2 3 X X X X Ventilation setting absent 1 A 2 3 X X X X Ventilation setting low 1 A 2 3 X X X X Ventilation setting medium 1 A 2 3 X X X X Ventilation setting...

Страница 9: ...itches vary widely in model and are therefore not il lustrated here If required the bathroom switch can be turned on and off using a time delay entered via a digital operating device delay timer This...

Страница 10: ...ds READ Press for longer than 2 seconds SET This button allows you to programme two settings Press for less than 2 seconds Programme ventilation setting AUTO MANUAL Press longer than 2 seconds Program...

Страница 11: ...fly Wait until the comfort temperature appears 2 Press to return to the main screen Setting the comfort temperature 1 Press longer than 2 seconds Wait until the comfort temperature e g 20 0 starts bli...

Страница 12: ...lation volume can be set as follows 1 Press to increase the ventilation volume 2 Press to decrease the ventilation volume During manual ventilation the CC Ease panel will not dis play AUTo but MANUAL...

Страница 13: ...Wait until the programme position e g 1 starts blinking 5 Select the desired programme position using or 6 Press Wait until the hour e g 7 starts blinking 7 Select the desired start time in hours usin...

Страница 14: ...enu using or e g P sub menu 23 5 Press Entering settings in P menus The minimum and maximum values for the available parameters are preset in the software 6 Select a new value for the programme using...

Страница 15: ...rating the bathroom switch the ComfoAir switches back to the normal setting Low voltage input 0 Min 120 Min 30 Min P23 Optional Note only applies to systems fitted with a hardwired 3 position switch O...

Страница 16: ...pplies to systems fit ted with a CC Ease panel Time for the Boost setting After pressing continuosly 2 sec on the CC Ease panel the ComfoAir will switch to the high setting for x minutes and then auto...

Страница 17: ...time it is recommended to replace the filters and clean the valves first During the construction phase the ventilation system could have become dirty with building dust 2 4 2 Cleaning the valves in yo...

Страница 18: ...mmunication has been estab lished Subsequently in the event of a malfunction or filter dirty alert both indicators will flash red 3 times After that both indicators will light up green once more 2 5 3...

Страница 19: ...94 Company register Zwolle 05022293 EEC declaration of conformity Machine description heat recovery units ComfoAir 160 series Complies with the following directives Machinery Directive 2006 42 EEC Low...

Страница 20: ...Zehnder Group Nederland B V Lingenstraat 2 8028 PM Zwole Nederland Tel 038 429 69 11 Fax 038 422 56 94 Internet www jestorkair nl E mail info jestorkair nl Zehnder Group Nederland B V 849050968 0112...

Отзывы: