EN - 14
The installer will have set all the valves to ensure the op-
timum performance of the ventilation system. Therefore,
do not change the setting of the valves.
After cleaning, make sure that all valves are
placed back with the same setting (and in ex-
actly the same ventilation hole in the wall or
ceiling) AT ALL TIMES. Otherwise, system per-
formance will be compromised.
2.5 Malfunctions
Malfunctions in the ComfoAir are reported as follows:
• The malfunction alert appears on the display,
• The malfunction alert appears on the CC Ease panel;
• The malfunction indicator on the 3-position switch
lights up.
A concise explanation of methods of reporting malfunc-
tions is given in the paragraphs below.
2.5.1 Malfunction alerts on the digital operating
device
In the event of a malfunction, the corresponding malfunc-
tion code will be displayed on the digital operating device
of the ComfoAir.
2.5.2 3-position switch with malfunction
indicators
The 3-position switches that are fitted with a malfunction
indicator show when a malfunction or filter dirty alert has
occurred. Depending on the type of the 3-position switch,
this is done in one of the following two ways:
• 3-position switch with malfunction indicator.
In the event of a malfunction or filter dirty alert the
indicator lights up;
• Wireless 3-position switch with malfunction indica-
tor.
The malfunction indicators will light up once this
3-position switch is used. One indicator will light up
green to indicate communication has been estab-
lished. Subsequently, in the event of a malfunction or
filter dirty alert both indicators will flash red 3 times.
After that, both indicators will light up green once
more.
2.5.3 What to do in the event of a malfunction
In the event of a malfunction, contact the installer. Note
down the malfunction code that appears on the digital
operating device. Make a note of your ComfoAir type.
This is given on the identification plate on the top of the
ComfoAir. The system should not be disconnected from
the power supply, unless the ComfoAir must be taken out
of service due to a serious malfunction, or for filter clean-
ing/replacement or any other compelling reasons.
If the ComfoAir is disconnected from the power
supply, mechanical ventilation of the dwelling
will cease. This can lead to a build-up of moi-
sture and results in problems with mould. Long-
term deactivation of the ComfoAir must there-
fore be prevented.
Condensation may form on the outside of the
ComfoAir if the unit is fitted in a space with hi-
gher average humidity levels (such as a ba-
throom, shower, toilet or kitchen). This is not a
problem for the ComfoAir.
2.6 End of useful life
Consult with the supplier about what should be
done with the ComfoAir at the end of its useful life. If the
ComfoAir cannot be returned to the supplier, avoid dis-
posing of it with the domestic waste, and ask your local
council about the options for recycling the components
or processing the materials in an environmentally friendly
manner.
Furthermore, do
not
dispose of batteries from the wi-
reless (RF) switches with the normal waste, but bring
them to the specially designated disposal locations.