GB

B

especially after longer standstill period particulates, at times highly acidic, can affect or destroy parts of the 
tank.

  

The upper part of the pump can be removed without the use of tools by carefully moving the 4 laces on 
the  upper  part  of  the  pump  outward  (see  figure  8).  The  upper  part  can  then  completely  be removed 
and the float switch and the bottom part of the pump body as well as the tank (bottom part) are  freely 
accessible.  These  parts  can  now  be  washed  with  warm  water  and  mild  soap.  After cleaning, place 
the upper part on the lower (tank) part. A latching can be heard. Connect the pump to the mains  and fill 
water into the tank through one of the inlets. After having filled the tank with about 1.5 l the system will 
start automatically and discharge the water into the canalization.    

WARNING:

 

All points pertaining to installation and start up (see point 4) must be observed 

when pump is returned to service. 

 WARNING

Unit must be disconnected from the power source before 

servicing or performing pump maintenance! 

7 . Warranty  

The warranty period for this product is 24 months from date of purchase. Proof of purchase must be 
provided. 
Any material or manufacturing defect within this timeframe will be rectified or repaired free of cost. Any 
damage  resulting  from  misuse,  in  particular  non-observance  of  the  instruction  manual  and excessive 
wear and tear is excluded from warrantee. Any unauthorized modifications or opening of the product will 
void the warranty. 

8.

 

Troubleshooting

Problem

Probable Cause

 

Remedy

 

Low flow rate

 

Outlet piping clogged or kinked

 

Clean / remove kink

 

Check valve contaminated

 

Clean

 

Head to large

 

Reduce head

 

Motor is idle or does not start

No voltage present 

Check power supply

 

Plug not plugged in

 

Plug in plug

 

Pump blocked by mud or solids Clean tank and pump body

 

Defective motor

 

Replacement by qualified personnel

Defective electronics

 

Replacement by qualified personnel

Motor running, pump does not 
deliver

 

Outlet piping clogged or kinked

 

Clean / remove kink

 

Check valve contaminated

 

Clean

 

Pump does not operate 
automatically

 

Float switch contaminated

 

Clean

 

Micro-switch defective

 

Replacement by qualified personnel

Содержание ZKH 15

Страница 1: ...Kondensathebeanlage Condensate pump ZKH 15 Betriebsanleitung Operating Instructions GB D Zehnder Pumpen GmbH Zw nitzer Stra e 19 08344 Gr nhain Beierfeld Deutschland www zehnder pumpen de...

Страница 2: ...d evtl Transportsch den zu pr fen Bei M ngeln informieren Sie bitte umgehend Ihren Fachh ndler Die Pumpe niemals am Kabel aus der Verpackung ziehen und transportieren F r den Betrieb der Pumpe ist ein...

Страница 3: ...tung angeschlossen wird ACHTUNG Bei Nichtbeachtung besteht im Falle eines R ckstaus aus der Kanalisation berflutungsgefahr der Kellerr ume 4 3 Signalkabel Die Pumpe ist neben dem Netzkabel POWER mit e...

Страница 4: ...uf den Tank aufgesetzt werden Dieses rastet h rbar ein Nun sollte die Anlage 2 3 mal mit sauberem Wasser gesp lt werden Nach dem Einstecken des Netzsteckers wird ber eine der Einlauf ffnungen Wasser e...

Страница 5: ...w hrleistung ausgenommen sind Sch den die auf unsachgem em Gebrauch oder auf Verschlei beruhen Folgesch den die durch Ausfall der Anlage auftreten werden von uns nicht bernommen Sollte ein Gew hrleist...

Страница 6: ...r remove the pump from the packaging by holding on to the cable An orderly grounded mains supply and residual current circuit breaker of max 30mA disconnecting all phases is required for the operation...

Страница 7: ...stem for the connection as an alarm 4 4 Testing WARNING Pull out the tab before testing or operating see figure6 The operation of the pump can be tested by activating the test switch without filling t...

Страница 8: ...efore servicing or performing pump maintenance 7 Warranty The warranty period for this product is 24 months from date of purchase Proof of purchase must be provided Any material or manufacturing defec...

Отзывы: