4.2 Pressure connection 

The pressure port is equipped with a check valve. PVC tubing with an inner diameter of 9mm is to 
be tightly connected to the pressure port (accessory, model Neotech 360-6MT is equipped with 6 m 
of PVC tubing), see figure 3. 
The  PVC-tubing  is  to  be  secured  with  a  hose  clamp  (not  supplied)  avoiding  any  kinks,  ties  and 
connected to the drain pipe of the canalization.  
In  case  of  an  installation  in  the  basement  below  the  level  of  backed-up  water  (locally  defined; 
generally the upper edge of the street) it must be ensured that the pressure piping is lead above this 
level and then connected downward to the drain pipe.  

 WARNING:  In case of non-observance the basement may be flooded in the event of 
a flow back from the canalization! 

4.3 Signalling cable 

In addition to the power cord (POWER), the pump is also equipped with a signalling cable (ALARM). 
See figure 4 

Figure 4 - Inlet adapter

 

Figure 5 - Contact configuration, signalling cable

 

The  signalling  cable  (dry  contact)  can  be  used  to  either  conduct  a  safety  shutdown  of  the 
condensing  boiler  (COM  and  NO)  or  to  activate  an  external  low  voltage  alarm  system  (COM  and 
NC). See figure 5 for contact configuration. 

 Please refer to the instruction manual of the condensing boiler for the connection as 
a  safety  shutdown  or  to  the  manual  of  the  alarm  system  for  the  connection  as  an 
alarm. 

4.4 Testing 

WARNING: Pull out the tab before testing or operating (see figure6) 

The  operation  of  the  pump  can  be  tested  by  activating  the  test-switch  without  filling  the  tank  by 
using a screwdriver. Insert the screwdriver in the respective opening to activate the switch and start 
the pump. The switch is deactivated by removing the screwdriver and the pump stops (see figure 7). 
This  test  is  only  to  be  conducted  briefly  for  a  couple  of  seconds  to  avoid  the  pump  from  being 
damaged due to running dry.  
It is imperative to remove the screwdriver again! 

Figure 6

 

Figure 7

 

Figure 8

 

5.

 

Limitation of use and improper operation:

WARNING: 

 

This  pump 

may

 

not  to  be  used

 for  waste  water,  in  particular  liquids 

containing  solids

 

liquids  with  abrasive  content  as  well  as 

flammable  and  explosive

 

liquids.  

6.

 

Maintenance

 WARNING

Ensure that the power is disconnected before performing any 

service or maintenance! 

The proper function of the pump, its wear parts and its product life are mainly dependant on regular 
servicing and maintenance of this unit. Particulates settle on the bottom of the tank in the course of 
time.  This  sediment  can  lead  to  pump  clogging  and  block  the  float  switch.  It  is  therefore 
recommended  to  service  the  pump,  piping,  inlets  and  pressure  port  biannually  and,  if  necessary, 
clean  the  respective  areas  and  parts.  This  is  especially  necessary  in  connection  with  the  general 
maintenance of the heating system prior to the start of the heating period. In the course of time and 

Содержание ZKH 15

Страница 1: ...Kondensathebeanlage Condensate pump ZKH 15 Betriebsanleitung Operating Instructions GB D Zehnder Pumpen GmbH Zw nitzer Stra e 19 08344 Gr nhain Beierfeld Deutschland www zehnder pumpen de...

Страница 2: ...d evtl Transportsch den zu pr fen Bei M ngeln informieren Sie bitte umgehend Ihren Fachh ndler Die Pumpe niemals am Kabel aus der Verpackung ziehen und transportieren F r den Betrieb der Pumpe ist ein...

Страница 3: ...tung angeschlossen wird ACHTUNG Bei Nichtbeachtung besteht im Falle eines R ckstaus aus der Kanalisation berflutungsgefahr der Kellerr ume 4 3 Signalkabel Die Pumpe ist neben dem Netzkabel POWER mit e...

Страница 4: ...uf den Tank aufgesetzt werden Dieses rastet h rbar ein Nun sollte die Anlage 2 3 mal mit sauberem Wasser gesp lt werden Nach dem Einstecken des Netzsteckers wird ber eine der Einlauf ffnungen Wasser e...

Страница 5: ...w hrleistung ausgenommen sind Sch den die auf unsachgem em Gebrauch oder auf Verschlei beruhen Folgesch den die durch Ausfall der Anlage auftreten werden von uns nicht bernommen Sollte ein Gew hrleist...

Страница 6: ...r remove the pump from the packaging by holding on to the cable An orderly grounded mains supply and residual current circuit breaker of max 30mA disconnecting all phases is required for the operation...

Страница 7: ...stem for the connection as an alarm 4 4 Testing WARNING Pull out the tab before testing or operating see figure6 The operation of the pump can be tested by activating the test switch without filling t...

Страница 8: ...efore servicing or performing pump maintenance 7 Warranty The warranty period for this product is 24 months from date of purchase Proof of purchase must be provided Any material or manufacturing defec...

Отзывы: