18
1.4 Range of application
The waste water ejection units of the type series UFB are especially designed for underground installation.
They are used for the automatic disposal of domestic waste water and rain water in cellar rooms (e.g. floor
drains, washing machines, wash-bowls, and showers) below the backwater level.
ATTENTION The waste water ejection units of the type series UFB / S-UFB
must not
be used for the
discharge of sewages containing excrements or fat.
1.5 Scope of delivery
The waste water ejection units are delivered ready to plug in, completely with pump, floating switch and non-
return valve as well as a grid and an odour stopper.
1.6 Special accessories
-
Connection piece for supplementary lateral inlets of DN 50, DN 70 and DN 100
-
Attachment piece with sealing for height compensation
-
Cover plate (alternative to grid)
2. Safety:
( from:“VDMA sheet 24 292“)
The operation manual at hand provides basic notes which must be taken into account during assembly,
operation and maintenance works. Therefore, before assembly and commissioning, this operation manual
must be read by the assembler as well as by the responsible personnel/operator at all costs. It always must be
available on site of operation of the machine/unit.
The general safety notes listed under the main point safety are not the only notes to be taken into account.
Please also observe the specific safety instructions, such as those for private use, listed under other main
points.
2.1 Marking of the notes contained in the operation manual
The safety notes contained in this operation manual which can cause danger to persons are specifically
marked by the following general danger symbol
Safety sign according to DIN 4844 - W 9,
The following symbol warns against dangers caused by voltage
Safety sign according to DIN 4844 - W 8.
In case of safety notes the non-observance of which can cause danger to the machine and its functioning, the
word
ATTENTION
is inserted.
Notes that are directly attached to the machine, such as - arrow indicating the direction of rotation
- marking of liquid connections
must be observed and kept in completely readable condition at all costs.
Содержание S-UFB 200 Series
Страница 12: ...12 Anhang A Einbaubeispiel...
Страница 13: ...13 Anhang B Abmessungen DN 70 Rohr Da 75 DN 70 Rohr Da 75...
Страница 25: ...25 Appendix A Installation example Backwater level to channel Ventilation line and cable entry Pressure pipe...
Страница 26: ...26 Appendix B Dimensions DN 100 Pipe Da 110 DN 70 Pipe Da 75...
Страница 39: ...39 Annexe B Dimensions Tuyau rigide D 75 Tuyau rigide D 110...