background image

 

18 

1.4 Range of application 

 

The  waste  water  ejection  units  of  the  type  series  UFB  are  especially  designed  for  underground  installation. 
They  are  used  for  the  automatic  disposal  of  domestic  waste  water  and  rain  water  in  cellar  rooms  (e.g.  floor 
drains, washing machines, wash-bowls, and showers) below the backwater level. 

ATTENTION   The  waste  water  ejection  units  of  the  type  series  UFB  /  S-UFB 

must  not

  be  used  for  the 

discharge of sewages containing excrements or fat.  
 
 

1.5 Scope of delivery 

 
The waste water ejection units are delivered ready to plug in, completely with pump, floating switch and non-
return valve as well as a grid and an odour stopper.  
 
 

1.6 Special accessories 

 

-

 

Connection piece for supplementary lateral inlets of DN 50, DN 70 and DN 100 

-

 

Attachment piece with sealing for height compensation 

-

 

Cover plate (alternative to grid) 

 
 

2. Safety: 

( from:“VDMA sheet 24 292“) 
 
The  operation  manual  at  hand  provides  basic  notes  which  must  be  taken  into  account  during  assembly, 
operation  and  maintenance  works.  Therefore,  before  assembly  and  commissioning,  this  operation  manual 
must be read by the assembler as well as by the responsible personnel/operator at all costs. It always must be 
available on site of operation of the machine/unit. 
 
The  general  safety  notes  listed  under  the  main  point  safety  are  not  the  only  notes  to  be  taken  into  account. 
Please  also  observe  the  specific  safety  instructions,  such  as  those  for  private  use,  listed  under  other  main 
points. 
 

2.1  Marking of the notes contained in the operation manual 
 

The  safety  notes  contained  in  this  operation  manual  which  can  cause  danger  to  persons  are  specifically 
marked by the following general danger symbol  

 

 

 

 
Safety sign according to DIN 4844 - W 9, 
 

The following symbol warns against dangers caused by voltage 

 

 

 

 
Safety sign according to DIN 4844 - W 8. 
 

In case of safety notes the non-observance of which can cause danger to the machine and its functioning, the 
word 

ATTENTION

 is inserted. 

 
Notes that are directly attached to the machine, such as   - arrow indicating the direction of rotation 
 

 

 

 

 

 

 

 

    - marking of liquid connections 

 
must be observed and kept in completely readable condition at all costs. 
 

 

 

Содержание S-UFB 200 Series

Страница 1: ...Schmutzwasser Hebeanlage Waste Water Ejector Unit Station de relevage des eaux harg es UFB 200 S UFB 200 Betriebsanleitung Operating Instructions Manuel d utilisation UFB 200 S UFB200...

Страница 2: ...f r den Betreiber Bediener 6 2 6 Sicherheitshinweise f r Wartungs Inspektions und Montagearbeiten 6 2 7 Eigenm chtiger Umbau und Ersatzteilherstellung 7 2 8 Unzul ssige Betriebsweisen 7 3 Transport un...

Страница 3: ...igen Fassung entsprechen EG Niederspannungsrichtlinie 2014 35 EU EMV Richtlinie 2014 30 EU Maschinenrichtlinie 2006 42 EG Angewendete bereinstimmende Normen insbesondere EN 60335 1 2012 A11 2014 EN 60...

Страница 4: ...Pumpen GmbH Zw nitzer Stra e 19 08344 Gr nhain Beierfeld Baugr en UFB 200 30 UFB 200 35 und UFB 200 40 S UFB 200 30 S UFB 200 35 und S UFB 200 40 Stand der Betriebsanleitung Februar 2015 1 2 Anfragen...

Страница 5: ...undlegende Hinweise die bei Aufstellung Betrieb und Wartung zu beachten sind Daher ist diese Betriebsanleitung unbedingt vor Montage und Inbetriebnahme vom Monteur sowie dem zust ndigen Fachpersonal B...

Страница 6: ...verh tung sowie eventuelle interne Arbeits Betriebs und Sicherheitsvorschriften des Betreibers sind zu beachten 2 5 Sicherheitshinweise f r den Betreiber Bediener F hren hei e oder kalte Maschinenteil...

Страница 7: ...nlage sollte waagerecht stehen 4 Beschreibung Aufbau und Wirkungsweise Die Hebeanlagen sind steckerfertig f r den Anschlu an 230 V 50 Hz Wechselstrom montiert Der Motor ist mit einem thermischen berla...

Страница 8: ...rkehr Durch die max Schlitzbreite von 8 mm ist der Einsatz im sog Barfu bereich z B Badezimmer m glich 5 1 Anschlu der Anlage a Vor dem Einbau sind alle Teile auf u ere Transportsch den zu berpr fen b...

Страница 9: ...zsteckers ist die Anlage betriebsbereit so da beim Zulauf von Wasser der Schwimmerschalter die Pumpe automatisch schaltet Mit dem als Zubeh r erh ltlichen Aufsatzst ck l t sich die Einbautiefe Beh lte...

Страница 10: ...rekte Position lt Abbildung 1 achten und der O Ring in die vorhandene Nut zwischen Siphon und Beh lter sorgf ltig eingepre t Bei starker Verschmutzung oder Besch digung ist der O Ring zu erneuern Zum...

Страница 11: ...hl durch Reparatur oder Austausch des Ger tes unentgeltlich alle M ngel die auf Material oder Herstellungsfehler beruhen Von der Gew hrleistung ausgenommen sind Sch den die auf unsachgem en Gebrauch u...

Страница 12: ...12 Anhang A Einbaubeispiel...

Страница 13: ...13 Anhang B Abmessungen DN 70 Rohr Da 75 DN 70 Rohr Da 75...

Страница 14: ...E 15 Einlaufstutzen DN 50 20752 7 1 O Ring f r Siphon 11526 16 1 Einlaufstutzen DN 70 bis 04 2018 11495 8 1 1 Pumpe f r UFB 200 30 11523 16 Einlaufstutzen DN 70 20753 8 2 1 Pumpe f r UFB 200 35 11540...

Страница 15: ...working 19 2 5 Safety notes for the operator user 19 2 6 Safety notes concerning maintenance inspection and assembly works 19 2 7 Unauthorised modification and fabrication of spare parts 20 2 8 Unauth...

Страница 16: ...relevant regulations in the respective valid version EC low voltage directive 2014 35 EU EMC directive 2014 30 EU Machinery directive 2006 42 EC Applied conform standards particularly EN 60335 1 2012...

Страница 17: ...Beierfeld Manufactured sizes UFB 200 30 UFB 200 35 and UFB 200 40 S UFB 200 30 S UFB 200 35 and S UFB 200 40 State of the operation manual Feb 2015 1 2 Enquiries and orders In case of enquiries or ord...

Страница 18: ...eration and maintenance works Therefore before assembly and commissioning this operation manual must be read by the assembler as well as by the responsible personnel operator at all costs It always mu...

Страница 19: ...well as possible internal working operating and safety instructions of the operator must be observed 2 5 Safety notes for the operator user Hot or cold machine components which could cause danger mus...

Страница 20: ...horizontal position 4 Description Composition and mode of operation The ejection units are assembled ready for connection to 230 V 50 Hz alternating current The motor is equipped with a thermal overlo...

Страница 21: ...lled barefoot areas e g bath room is possible 5 1 Connection of the unit c Before mounting all parts must be checked for external transport damages d Inlets Normally the surface water flows through th...

Страница 22: ...so that the floating switch activates the pump automatically with the inlet of water In the attachment piece available as accessory the installation depth tank 432 mm can be increased continuously bet...

Страница 23: ...ion according to image 1 and the O ring will be carefully pressed into the existing groove between siphon and tank In case of a heavy contamination or degradation the O ring must be replaced Finally t...

Страница 24: ...attributed to material or fabrication defects by either repairing the unit or by replacing the defective parts to our choice Defects which are attributed to misuse or wear are excluded from warranty...

Страница 25: ...25 Appendix A Installation example Backwater level to channel Ventilation line and cable entry Pressure pipe...

Страница 26: ...26 Appendix B Dimensions DN 100 Pipe Da 110 DN 70 Pipe Da 75...

Страница 27: ...1 Inlet joint DN 50 20752 7 1 O ring for siphon 11526 16 1 Inlet joint DN 70 till 04 2018 11495 8 1 1 Pump for UFB 200 30 11523 16 1 Inlet joint DN 70 20753 8 2 1 Pump for UFB 200 35 11540 17 1 Inlet...

Страница 28: ...de s curit pour l op rateur l utilisateur 32 2 6 Consignes de s curit pour les travaux de maintenance inspection et montage 32 2 7 Modifications arbitraires et fabrication des pi ces de rechange 33 2...

Страница 29: ...s aff rentes suivantes Directive 2014 35 EU relative la basse tension Directive 2014 30 EU relative la comptabilit lectromagn tique Directive 2006 42 EG relative aux machines Normes harmonis es appliq...

Страница 30: ...bH Zw nitzer Stra e 19 08344 Gr nhain Beierfeld Allemagne Taille de construction UFB 200 30 UFB 200 35 et UFB 200 40 S UFB 200 30 S UFB 200 35 et S UFB 200 40 Date du manuel d utilisation Juin 2009 1...

Страница 31: ...p rativement avoir t lu avant le montage et la mise en service par le monteur ainsi que par le personnel sp cialis l exploitant responsable et doit tre tout moment disponible sur le lieu d exploitatio...

Страница 32: ...nant le travail et le service doivent tre respect s 2 5 Consignes de s curit pour l op rateur l utilisateur Si les parties de l installation chaudes ou froides sont susceptibles d tre source de danger...

Страница 33: ...doivent se faire dans un lieu frais sombre sec et l abri du gel Le syst me doit tre install en position horizontale 4 Description Installation et mode d action Les stations de relevage sont mont es p...

Страница 34: ...isageable dans ce que l on appelle une zone pieds nus par ex une salle de bain par une largeur maximale de fente de 8 mm 5 1 Raccordement du syst me e Avant la mise en place v rifier qu aucune partie...

Страница 35: ...alimentation lectrique est branch e de sorte que l interrupteur flotteur active automatiquement la pompe en cas d arriv e d eau La profondeur de montage r servoir 432 mm peut tre augment e en continu...

Страница 36: ...uis ins rez soigneusement le joint torique dans la rainure existante entre le siphon et le r servoir Remplacez le joint torique si ce dernier est fortement encrass ou endommag Enfin replacez le caille...

Страница 37: ...de r parer ou de remplacer l appareil selon notre bon vouloir en cas de d faillances dues au mat riel ou au fabricant Sont exclus de la garantie les dommages dus une utilisation non conforme ou l usu...

Страница 38: ...38 Annexe A exemple d utilisation Niveau de reflux Vers les gouts Conduite de refoulement Conduite d a ration et entr e du c ble...

Страница 39: ...39 Annexe B Dimensions Tuyau rigide D 75 Tuyau rigide D 110...

Страница 40: ...oint torique pour siphon 11526 16 1 Tuyauterie de ventilation DN 70 jusqu au 04 2018 11495 8 1 1 Pompe pour UFB 200 30 11523 16 1 Tuyauterie de ventilation DN 70 20753 8 2 1 Pompe pour UFB 200 35 1154...

Отзывы: