Zeck Audio CHAMP 2.250 Скачать руководство пользователя страница 17

17

CHAMP Series owner‘s manual © Zeck Audio 2000

K000001A01

In

 Bridge

 mode, the two middle Speakon connectors must be 

used.  If both channel groups 1+2 and 3+4 are used in bridged 

mode, the “1+2” output can be used to drive the speaker on 

the  left  while  the  “3+4”  output  drives  the  speakers  on  the 

right for a powerful stereo setup.

3.3.3 Active stereo 2-way operation

In  active  stereo  2-way  operation,  each  output  amplifier  of 

the  CHAMP  4.250X  has  to  amplify  only  a  portion  of  the 

signal  spectrum,  making  for  a  more  efficient  use  of  the 

amplifiers  and speakers. For full active 2-way operation of the 

CHAMP 4.250X, put both switches (17) of the amplifier to their 

“X-OVER“ or “X-OVER x 10” position. Switch (10) for channel 

1+2 must be in its “Stereo” position. 

In this mode, the input signals of channel 1 and channel 2  

(inputs 3 and 4 remain unused) are split up into a highpass 

(treble) and a lowpass (bass) signal, resulting in a stereo signal 

with a treble and bass signal for each channel.

Active  stereo  2-way  operation  employs  a  bass  speaker 

cabinet  (subwoofer)  plus  a  high-frequency  cabinet  (top) 

on  each  stage  side.  The  high-frequency  cabinets  must  be 

connected to channels 1 and 2, the bass cabinets to channels 

3 and 4.

1+2

3+4

2+

2-

1-

1+

2+

2-

1-

1+

Signal 1+2 (+)

Signal 1+2 (-)

Signal 3+4 (+)

Signal 3+4 (-)

Fig.11:  Required Speakon plug wiring for CHAMP 4.250X in

Parallel mode

The lowpass ouputs 3 and 4 also carry their corresponding 

highrange signals so that 4-way speaker cables can be used 

for convenient and cable-saving wiring. Using 4-way speaker 

cables, however, requires that the connectors on the speaker 

cabinets are wired accordingly.

The  rotary  controls  (16)  are  used  to  adjust  the  crossover 

(separation) frequency between the high- and lowpass signals. 

If the switches (17) are in their “X-OVER“ position, the crossover 

frequency corresponds with the value given on the scale. If 

the switches (17) are in their “X-OVER x 10“ position, the value 

given on the scale must multiplied by 10 to obtain the actual 

crossover frequency. 

The “best”crossover frequency for each setup depends on 

the speaker systems used and should be available from the 

technical  specifications  of  the  cabinets. 

Attention: 

To  avoid 

speaker  damage,

 

never  operate  a  high/midrange  cabinet 

below its allowed lowest frequency.

2

2+

2-

1-

1+

Signal

High 2

1

4

3

Ground

Ground

Ground

2+

2-

1-

1+

Signal

High 1 

Signal

High 1

Signal

High 2 

2+

2-

1-

1+

2+

2-

1-

1+

Signal

Low 1

Signal

Low 2

Ground

Ground

Ground

Fig.11:  Required Speakon plug wiring for CHAMP 4.250X in

2-way active X-OVER mode

K000001A01.indd

12.12.2000, 14:21

16-17

Содержание CHAMP 2.250

Страница 1: ...N ON PROTECT SIGNAL LIMIT 2 0 4 6 8 8 10 12 14 18 24 dB LIMIT ON PROTECT SIGNAL POWER ON dB 2 0 4 6 8 8 10 12 14 18 24 CH 3 4 CHANNEL 3 CHANNEL 4 BRIDGE MODE CH 1 2 PROTECT SIGNAL LIMIT 2 0 4 6 8 8 10...

Страница 2: ...utzung Bei l ngerer Nichtbenutzung des Ger tes sollte das Netzkabel aus der Steckdose gezogen werden 8 Fremdk rper und Fl ssigkeiten Das Eindringen von Gegenst nden und Fl ssigkeiten in das Geh use is...

Страница 3: ...from the outlet when not used for a longer period 8 Object and liquid entry Care should be taken so that objects do not fall into and liquids are not spilled into the inside of the unit 9 Damage requi...

Страница 4: ...MP 4 250X 9 3 3 1 Anschluss der Eing nge 9 3 3 2 Anschluss der Lautsprecher Ausg nge 9 3 3 3 Aktiver Stereo 2 Weg Betrieb 10 4 Technische Daten 11 Contents Page 1 Quick reference 12 1 1 General remark...

Страница 5: ...den Einsatz auf B hnen f r Festinstallationen jeder Gr e f r Monitoring in Studios und f r viele andere Anwendungen Die insgesamt 5 Modelle der CHAMP Serie haben nicht nur unterschiedliche Leistungen...

Страница 6: ...3 SIGNAL 2 SIGNAL 1 SIGNAL GROUND INPUT CH 2 CH 1 CH 4 CH 3 CH 3 OUTPUT OUTPUT INPUT INPUT THIS APPARATUS MUST BE EARTHED TO REDUCETHE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS APPLIANCETO RA...

Страница 7: ...Hochp ssen zugeordnet Kan le 3 und 4 den Tiefp ssen 1 3 Die Modelle der CHAMP Serie Die Verst rker der CHAMP Serie sind in 5 unterschiedlichen Ausf hrungen erh ltlich Modell Nenn Ausgangsleistung an...

Страница 8: ...signal nur an Kanal 1 angeschlossen 3 1 2 Parallel Ausg nge Die beiden PARALLEL OUTPUT XLR Buchsen sind parallel zu den Eingangsbuchsen geschaltet und dienen zum Anschluss weiterer Verst rker 3 1 3 An...

Страница 9: ...tellt Der Volumenregler von Kanal 2 4 muss dabei auf Rechtsanschlag stehen 3 3 CHAMP 4 250X Die CHAMP 4 120X hat vier v llig voneinander unabh ngige Kan le Die vier Kan le k nnen dazu benutzt werden z...

Страница 10: ...hp ssen und Tiefp ssen eingestellt Ist der Schalter 17 in der Stellung X OVER stimmt die Skalenangabe direkt mit der Frequenz berein bei der Schalterstellung X OVER x 10 ist der Skalenwert mit dem Fak...

Страница 11: ...rkung St rspannungsabstand 22Hz 22kHz Effektivwert unbewertet bezogen auf Nennleistung bersprechd mpfung 1kHz an 8Ohm Eingangs Gleichtaktunterdr ckung 100Hz 1Veff Ausgangs Gleichspannung Eingangsimped...

Страница 12: ...1 Front panel of 2 channel models Mains power switch with indicator lamp 1 2 Output level control Each channel has an individual level control 3 PROTECT indicator LED Indicates when protection circuit...

Страница 13: ...ALIFIED PERSONNEL RISQUE DE CHOC ELECTRIQUE NE PAS OUVRIR CAUTION CAUTION HAZARDOUS ENERGY MAKE PROPER SPEAKER CONNECTIONS REFER TO OPERATING MANUAL RISK OF ELECTRIC SHOCK DO NOT OPEN WARNING USE ONLY...

Страница 14: ...only This control is used to adjust the crossover frequency between high and lowpass of the internal 2 way crossvers The internal crossoverers are activated or bypassed by means of the slide switch 1...

Страница 15: ...re power amplifiers 3 1 3 Connection of speakers Each channel is equipped with Speakon 4 pole and binding post speaker connectors In Stereo mode the Speakon connectors are wired so that the output sig...

Страница 16: ...CHAMP 4 250X has four totally independent channels which can be used to produce two stereo signals or four monaural signals e g to supply different rooms with sound In Bridge mode channels 1 2 and 3...

Страница 17: ...hannels 1 and 2 the bass cabinets to channels 3 and 4 1 2 3 4 2 2 1 1 2 2 1 1 Signal 1 2 Signal 1 2 Signal 3 4 Signal 3 4 Fig 11 Required Speakon plug wiring for CHAMP 4 250X in Parallel mode The lowp...

Страница 18: ...1kHz 8ohms Voltage gain S N ratio 22Hz 22kHz r m s unweighted ref to nominal output power Crosstalk attenuation 1kHz into 8ohms Input CMRR 100Hz 1V r m s Output d c voltage Input impedance balanced w...

Страница 19: ......

Страница 20: ...Zeck Audio Turnhallenweg 6 D 79183 Waldkirch Germany Phone 49 7681 2004 0 Fax 49 7681 2004 44 Email info Zeck Audio de Homepage www zeck audio de...

Отзывы: