K000001A01

Cooling fans

The fan outlets must never be covered.

7

8

Input connector

All input connectors are 1⁄4“/XLR compound recepta-

cles with balanced signal wiring. The pin configuration 

is as follows:

 

 

XLR 

  1/4“

 

  

  2 

   tip

Signal -   

  3 

  ring

Ground   

  1 

sleeve

9

PARALLEL OUTPUT 

(2-channel models only)

This balanced XLR output is parellel-wired to the input 

connectors and can be used for linking of more power 

amplifiers.

10

MODE Switch

This switch is used to switch the amplifier to STEREO, 

PARALLEL or BRIDGE mode.

Attention:  In  BRIDGE  mode,  the  speakers  must  be 

connected  only  to  the  SIGNAL  terminals  with  no 

ground connection.

11

Binding post speaker terminals 

The  red  speaker  terminals  always  carry  the  output 

signal,  the  black  terminals  are  always  connected  to 

ground. In BRIDGE mode, the speakers must be con-

nected only to the red terminals. 

12

Speakon output connectors

The pin configurations of the Speakon connectors vary 

between amplifier models and channels. See chapter 

3 a detailed description of each model.

13

Automatic power circuit breaker 

This  automatic  power  circuit  breaker  becomes  trig-

gered when the current intake of the amplifier exceeds 

its upper allowed limit. The circuit breaker can be reset-

ted by pushing its button. If the reset fails, the ampli-

fier should be sent in for servicing.

14

Mains power input connector

15

Speakon connector for BRIDGE MODE

(CHAMP 4.250X only)

These  Speakon  output  connectors  are  specially  pro-

vided for speaker connection in BRIDGE MODE. These 

connectors use only terminals 1+ and 1-.

17

Selector switch for  crossover 

(CHAMP 4.250X only)

In the left position of the switch, the crossover circuit 

is  bypassed  for  a  linear  frequency  response  of  all 

channels. The middle position activates the crossover 

at  the  separation  frequency  that  is  printed  on  the 

adjustment  knob  scale  (60Hz  to  250Hz).  In  the  right 

postion of the switch the value of the knob scale has 

to be multiplied by 10 (600Hz to 2.5kHz).

Attention: When the crossover is activated, the MODE 

switch  (10)  of  channels  1+2  must  be  in  its  “Stereo“ 

position.

16

Control potentiometer for crossover frequency

(CHAMP 4.250X only)

This control is used to adjust the crossover frequency 

between  high-  and  lowpass  of  the  internal  2-way 

crossvers.  The  internal  crossoverers  are  activated  or 

bypassed by means of the slide switch (17) below the 

control potentiometer. When the crossover is activated, 

channels 1 and 2 are assigned to the highpass filter, 

channels 3 and 4 to the lowpass filter.

1.3 Models of the Champ series

The CHAMP series models are available in 5 versions:
Model      

 

  Nominal output power

 

 

 

into 4 ohms 

into 8 ohms 

 

Champ 2.250 

 

  2 × 250 W 

  2 × 150 W 

Champ 2.350 

 

  2 × 350 W 

  2 × 220 W

Champ 2.500 

   

  2 × 500 W 

  2 × 330 W

Champ 4.125 

 

  4 × 125 W 

  4 × 80 W

Champ 4.250X   

  4 × 250 W 

  4 × 170 W

2. Instructions for all models

2.1 Placement of amplifier

The built-in cooling fans provide a steady front-to-rear flow of 

cooling air inside the amplifier. When setting up the amplifier, 

always care for sufficient clearance of the amplifier front and 

rear to assure unhindered airflow. In addition, always observe 

paragraphs 4, 5 and 6 of the safety instructions.

2.2 MODE SWITCH (10)

Before  connecting  the  amplifier,  use  the  MODE  SWITCH  of 

the amplifier to switch the amplifier to its desired operational 

mode. All CHAMP series amplifiers can be operated in 3 modes 

which  are  described  below.  The  4-channel  models  (CHAMP 

4.120 and CHAMP 4.250X) have two mode switches (channels 

1/2 and 3/4).

STEREO

In this mode, all channels of the amplifier work independently. 

This is the standard setting for two-channel or four-channel 

operation. Attention: When the built-in crossover is activated 

(CHAMP 4.250X only), the MODE switch (10) of channels 1+2 

must be in “Stereo” position.

PARALLEL

In this mode, two inputs are wired in parallel. If only one input 

is used, both outputs carry identical signals. The output levels 

can be adjusted individually. 

Caution: 

In this mode, the inputs 

of the channels are wired in parallel, not the outputs. Parallel-

wiring of amplifier outputs will inevitably lead to destruction 

of the amplifier.

BRIDGE MODE

This  mode  provides  considerably  more  output  power  by 

linking  two  channels  in  monaural  push-pull  configuration 

(see  chapter  4  for  available  output  power).  This  mode  is 

especially  recommended  for  driving  high-power  subwoofer 

cabinets  that  do  not  neccessarily  require  a  stereo  signal.  In 

addition  to  that,  the  BRIDGE  mode  can  be  used  to  directly 

drive  transformer-equipped  speaker  cabinets  in  a  constant-

voltage network.

K000001A01.indd

12.12.2000, 14:19

14-15

Содержание CHAMP 2.250

Страница 1: ...N ON PROTECT SIGNAL LIMIT 2 0 4 6 8 8 10 12 14 18 24 dB LIMIT ON PROTECT SIGNAL POWER ON dB 2 0 4 6 8 8 10 12 14 18 24 CH 3 4 CHANNEL 3 CHANNEL 4 BRIDGE MODE CH 1 2 PROTECT SIGNAL LIMIT 2 0 4 6 8 8 10...

Страница 2: ...utzung Bei l ngerer Nichtbenutzung des Ger tes sollte das Netzkabel aus der Steckdose gezogen werden 8 Fremdk rper und Fl ssigkeiten Das Eindringen von Gegenst nden und Fl ssigkeiten in das Geh use is...

Страница 3: ...from the outlet when not used for a longer period 8 Object and liquid entry Care should be taken so that objects do not fall into and liquids are not spilled into the inside of the unit 9 Damage requi...

Страница 4: ...MP 4 250X 9 3 3 1 Anschluss der Eing nge 9 3 3 2 Anschluss der Lautsprecher Ausg nge 9 3 3 3 Aktiver Stereo 2 Weg Betrieb 10 4 Technische Daten 11 Contents Page 1 Quick reference 12 1 1 General remark...

Страница 5: ...den Einsatz auf B hnen f r Festinstallationen jeder Gr e f r Monitoring in Studios und f r viele andere Anwendungen Die insgesamt 5 Modelle der CHAMP Serie haben nicht nur unterschiedliche Leistungen...

Страница 6: ...3 SIGNAL 2 SIGNAL 1 SIGNAL GROUND INPUT CH 2 CH 1 CH 4 CH 3 CH 3 OUTPUT OUTPUT INPUT INPUT THIS APPARATUS MUST BE EARTHED TO REDUCETHE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS APPLIANCETO RA...

Страница 7: ...Hochp ssen zugeordnet Kan le 3 und 4 den Tiefp ssen 1 3 Die Modelle der CHAMP Serie Die Verst rker der CHAMP Serie sind in 5 unterschiedlichen Ausf hrungen erh ltlich Modell Nenn Ausgangsleistung an...

Страница 8: ...signal nur an Kanal 1 angeschlossen 3 1 2 Parallel Ausg nge Die beiden PARALLEL OUTPUT XLR Buchsen sind parallel zu den Eingangsbuchsen geschaltet und dienen zum Anschluss weiterer Verst rker 3 1 3 An...

Страница 9: ...tellt Der Volumenregler von Kanal 2 4 muss dabei auf Rechtsanschlag stehen 3 3 CHAMP 4 250X Die CHAMP 4 120X hat vier v llig voneinander unabh ngige Kan le Die vier Kan le k nnen dazu benutzt werden z...

Страница 10: ...hp ssen und Tiefp ssen eingestellt Ist der Schalter 17 in der Stellung X OVER stimmt die Skalenangabe direkt mit der Frequenz berein bei der Schalterstellung X OVER x 10 ist der Skalenwert mit dem Fak...

Страница 11: ...rkung St rspannungsabstand 22Hz 22kHz Effektivwert unbewertet bezogen auf Nennleistung bersprechd mpfung 1kHz an 8Ohm Eingangs Gleichtaktunterdr ckung 100Hz 1Veff Ausgangs Gleichspannung Eingangsimped...

Страница 12: ...1 Front panel of 2 channel models Mains power switch with indicator lamp 1 2 Output level control Each channel has an individual level control 3 PROTECT indicator LED Indicates when protection circuit...

Страница 13: ...ALIFIED PERSONNEL RISQUE DE CHOC ELECTRIQUE NE PAS OUVRIR CAUTION CAUTION HAZARDOUS ENERGY MAKE PROPER SPEAKER CONNECTIONS REFER TO OPERATING MANUAL RISK OF ELECTRIC SHOCK DO NOT OPEN WARNING USE ONLY...

Страница 14: ...only This control is used to adjust the crossover frequency between high and lowpass of the internal 2 way crossvers The internal crossoverers are activated or bypassed by means of the slide switch 1...

Страница 15: ...re power amplifiers 3 1 3 Connection of speakers Each channel is equipped with Speakon 4 pole and binding post speaker connectors In Stereo mode the Speakon connectors are wired so that the output sig...

Страница 16: ...CHAMP 4 250X has four totally independent channels which can be used to produce two stereo signals or four monaural signals e g to supply different rooms with sound In Bridge mode channels 1 2 and 3...

Страница 17: ...hannels 1 and 2 the bass cabinets to channels 3 and 4 1 2 3 4 2 2 1 1 2 2 1 1 Signal 1 2 Signal 1 2 Signal 3 4 Signal 3 4 Fig 11 Required Speakon plug wiring for CHAMP 4 250X in Parallel mode The lowp...

Страница 18: ...1kHz 8ohms Voltage gain S N ratio 22Hz 22kHz r m s unweighted ref to nominal output power Crosstalk attenuation 1kHz into 8ohms Input CMRR 100Hz 1V r m s Output d c voltage Input impedance balanced w...