background image

 

109

bar codes in 

Appendix D, Numeric Bar Codes

. For example, to 

decode Codabar symbols containing between 4 and 12 characters, 
first scan Codabar - Length Within Range. Then scan 0, 4, 1, and 2 
(single digit numbers must always be preceded by a leading zero). 
To correct an error or change the selection, scan Cancel barcode. 

 

 

Any Length - Scan this option to decode Codabar symbols 
containing any number of characters within the decoder capability.   

 

 

Codabar - One Discrete Length 

 
 
 

 

 

 

Codabar - Two Discrete Lengths 

 
 
 

 

Codabar - Length Within Range 

 
 
 

 

 

 

Codabar - Any Length 

 

 

 
 

 
 
 
 
 

 
 

Содержание Z-3152 Series

Страница 1: ...1 Settings and Programming For 2D Image Scanners...

Страница 2: ...r translated into any human or computer or other language in any form or by any means electronic mechanical magnetic optical chemical biological manual or otherwise except for brief passages which may...

Страница 3: ...the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help For CE Countries It is in conformity...

Страница 4: ...selected barcode patches in this manual to affect setup and programming of your handheld 2D Image Reader Decoding options and interface protocols can be tailored to a specific application Setup parame...

Страница 5: ...eeper Volume High Handheld Hands free Scanner Level Trigger Mode Scan Module Presentation Handheld Hands free Scanner Low Power Power Mode Scan Module Continuous on Time Delay to Low Power Mode 1 0 Se...

Страница 6: ...the Set All Defaults parameter bar code scan the Disable Parameter Scanning bar code below To enable decoding of parameter bar codes scan Enable Parameter Scanning Enable Parameter Scanning Disable Pa...

Страница 7: ...4 Beeper Volume To select a beeper volume scan the Low Volume Medium Volume or High Volume bar code Low Volume Medium Volume High Volume...

Страница 8: ...eld of view it triggers and attempts to decode The range of object detection does not vary under normal lighting conditions This applies to decode mode only In this mode the unit does not enter its sl...

Страница 9: ...de attempt In low power mode the decoder enters into a low power consumption mode to preserve battery life after each decode attempt In continuous power mode power remains on after each decode attempt...

Страница 10: ...pon trigger pull or when the host attempts to communicate with the decoder Note 1 This parameter only applies when Power Mode is set to Low Power 2 This setting is not available for scan module since...

Страница 11: ...elow and then scan the 0 and 5 bar codes To correct an error or change the selection scan Cancel barcode Decode Session Timeout Timeout Between Decodes Same Symbol This option is used in presentation...

Страница 12: ...Good Decode Disable Presentation Mode Session Timeout To set the duration of the attempt to decode a bar code detected in presentation mode scan the bar code below Next scan three numeric bar codes fr...

Страница 13: ...ble Gain 100 Exposure Time 10 ms Snapshot Mode Timeout 0 30 seconds Snapshot Aiming Pattern Enable Image Cropping Disable Crop to Pixel Addresses 0 top 0 left 479 bottom 639 right Image Resolution Ful...

Страница 14: ...inder Disable Target Video Frame Size 2200 bytes Video View Finder Image Size 1700 bytes The parameters in this section control image capture characteristics Image capture occurs in all modes of opera...

Страница 15: ...t trigger event instructs the decoder to capture a high quality image and transmit it to the host A short time may pass less than 2 seconds between when the trigger is activated and the image is captu...

Страница 16: ...difficult image capture situations Enable Decoding Auto exposure Disable Decoding Auto exposure Decoding Illumination Selecting Enable Illumination causes the decoder to flash illumination on every i...

Страница 17: ...Disable Decode Aiming Pattern Image Capture Auto exposure Select Enable Auto exposure to allow the decoder to control gain settings and exposure integration time to best capture an image for the selec...

Страница 18: ...isable Image Capture Illumination Gain This parameter only applies when Decoding or Image Capture Auto exposure is disabled Gain is a means of amplifying the raw image data before it is converted into...

Страница 19: ...ight much like the shutter speed for a camera Generally the brighter the environment the shorter the exposure time Set the manual exposure time to one of the following values 5 ms 10 ms 15 ms 20 ms 25...

Страница 20: ...low followed by a bar code from Appendix D Numeric Bar Codes The default value is 0 which represents 30 seconds values increment by 30 For example 1 60 seconds 2 90 seconds etc Snapshot Mode Timeout S...

Страница 21: ...e If Disable Image Cropping is selected the full 640 x 480 pixels are presented If Enable is selected the decoder crops the image to the pixel addresses set in Crop to Pixel Addresses Enable Image Cro...

Страница 22: ...r a 4 row x 8 column image in the extreme bottom right section of the image set the following values Top 476 Bottom 479 Left 632 Right 639 To set the pixel address to crop to scan each Pixel Address b...

Страница 23: ...ombined to one pixel resulting in a smaller image containing the original content with reduced resolution Select one of the following values Resolution Value Uncropped Image Size Full 640 x 480 1 2 32...

Страница 24: ...ctor is selected scan the JPEG Quality Value bar code followed by 3 bar codes from Appendix D Numeric Bar Codes corresponding to a value from 5 to 100 where 100 represents the highest quality image If...

Страница 25: ...JPEG File Format TIFF File Format Bits per Pixel Select the number of significant bits per pixel BPP to use when capturing an image Select 1BPP for a black and white image 4BPP to assign 1 of 16 leve...

Страница 26: ...re capture area Output File Format Decoding a signature capture bar code de skews the signature image converts the image to a BMP JPEG or TIFF file format The output data includes the file descriptor...

Страница 27: ...JPEG Signature Format TIFF Signature Format Signature Capture Bits per Pixel Select the number of significant bits per pixel BPP to use when capturing a signature Select 1BPP for a black and white ima...

Страница 28: ...e in the range of 001 to 640 decimal Signature Capture Width Default 400 001 640 Decimal Signature Capture Height To set the height of the signature capture box scan the Signature Capture Height bar c...

Страница 29: ...an the bar code below followed by two bar codes from Appendix D Numeric Bar Codes corresponding to the 100 byte value from 800 to 3300 bytes For example to select 1500 bytes enter 1 5 To select 900 by...

Страница 30: ...ce with most system architectures System architectures that use RS 232C signal levels require a conversion circuitry The serial host type requires proper configuration of the sysconfig lines and typic...

Страница 31: ...ies and miscellaneous default parameters Serial Host Default Table Serial Host Parameters Parameter Default Serial Host Types Standard Baud Rate 9600 Parity Type None Stop Bit Select 1 Stop Bit Data B...

Страница 32: ...None None Ack Nak None Serial Response Time out 9 9 Sec 2 Sec 9 9 Sec 9 9 Sec 9 9 Sec 9 9 Sec Stop Bit Select One One One One One One ASCII Format 8 Bit 8 Bit 8 Bit 8 Bit 7 Bit 8 Bit Beep On BEL Disab...

Страница 33: ...None M M M len C len Codabar N len None N N N len N len Code 128 L len None K K K len L len I 2 of 5 I len None I I I len I len Code 93 None None L L L len None D 2 of 5 H len None H H H len H len UC...

Страница 34: ...ost Types To select a serial host interface scan one of the following bar codes SSI Host Enable Serial Host No Variant ICL Serial Wincor Nixdorf Serial Mode A Wincor Nixdorf Serial Mode B Olivetti ORS...

Страница 35: ...al host type bar code changes these settings OPOS JPOS Fujitsu Serial Baud Rate Baud rate is the number of bits of data transmitted per second Set the decoder s baud rate to match the baud rate settin...

Страница 36: ...33 Baud Rate 9600 Baud Rate 19 200 Baud Rate 38 400 Baud Rate 57 600 Baud Rate 115 200...

Страница 37: ...t Odd parity and the parity bit value is set to 0 or 1 based on data to ensure that an odd number of 1 bits are contained in the coded character Select Even parity and the parity bit value is set to 0...

Страница 38: ...xt character in the serial data stream The number of stop bits selected one or two depends on the number the receiving terminal is programmed to accommodate Set the number of stop bits to match host d...

Страница 39: ...ether or not the parity framing and overrun of received characters are checked The parity value of received characters is verified against the parity parameter selected above Check For Received Errors...

Страница 40: ...serts RTS 10 msec after sending the last character The host should respond by negating CTS The decoder checks for a de asserted CTS upon the next transmission of data During the transmission of data t...

Страница 41: ...ssion regardless of the state of CTS The decoder waits up to Host Serial Response Time out default for CTS to be asserted If CTS is not asserted during this time the decoder issues an error indication...

Страница 42: ...time out occurs ENQ When this option is selected the decoder waits for an ENQ character from the host before transmitting data If an ENQ is not received within the Host Serial Response Time out the d...

Страница 43: ...40 None ACK NAK ENQ ACK NAK with ENQ XON XOFF...

Страница 44: ...ecoder waits for an ACK NAK or CTS before determining that a transmission error has occurred This only applies when in one of the ACK NAK Software Handshaking modes or RTS CTS Hardware Handshaking opt...

Страница 45: ...BEL When this parameter is enabled the decoder issues a beep when a BEL character is detected on the serial line BEL is issued to gain a user s attention to an illegal entry or other important event...

Страница 46: ...43 Intercharacter Delay This parameter specifies the intercharacter delay inserted between character transmissions Minimum 0 msec Low 25 msec High 75 msec Maximum 99 msec...

Страница 47: ...nknown characters are characters the host does not recognize When Send Bar Codes with Unknown Characters is selected all bar code data is sent except for unknown characters and no error beeps sound on...

Страница 48: ...Suffix Values Prefix Suffix Value Full ASCII Code 39 Encode Character ASCII Character 1000 U NUL 1001 A SOH 1002 B STX 1003 C ETX 1004 D EOT 1005 E ENQ 1006 F ACK 1007 G BELL 1008 H BCKSPC 1009 I HOR...

Страница 49: ...024 X CAN 1025 Y EM 1026 Z SUB 1027 A ESC 1028 B FS 1029 C GS 1030 D RS 1031 E US 1032 Space Space 1033 A 1034 B 1035 C 1036 D 1037 E 1038 F 1039 G 1040 H 1041 I 1042 J 1043 K 1044 L 1045 1046 1047 O...

Страница 50: ...5 5 1054 6 6 1055 7 7 1056 8 8 1057 9 9 1058 Z 1059 F 1060 G 1061 H 1062 I 1063 J 1064 V 1065 A A 1066 B B 1067 C C 1068 D D 1069 E E 1070 F F 1071 G G 1072 H H 1073 I I 1074 J J 1075 K K 1076 L L 10...

Страница 51: ...R 1083 S S 1084 T T 1085 U U 1086 V V 1087 W W 1088 X X 1089 Y Y 1090 Z Z 1091 K 1092 L 1093 M 1094 N 1095 O _ 1096 W 1097 A a 1098 B b 1099 C c 1100 D d 1101 E e 1102 F f 1103 G g 1104 H h 1105 I i...

Страница 52: ...49 1109 M m 1110 N n 1111 O o 1112 P p 1113 Q q 1114 R r 1115 S s 1116 T t 1117 U u 1118 V v 1119 W w 1120 X x 1121 Y y 1122 Z z 1123 P 1124 Q 1125 R 1126 S 1127 Undefined 7013 ENTER...

Страница 53: ...USB host parameters To change any option scan the appropriate barcode s provided in the Parameter Descriptions section Note See Appendix A Standard Default Parameters for all user preferences hosts s...

Страница 54: ...e Note When changing USB Device Types the decoder automatically resets The decoder issues the standard startup beep sequences HID Keyboard Emulation Simple COM Port Emulation Symbol Native API SNAPI w...

Страница 55: ...sable SNAPI Status Handshaking USB Country Keyboard Types Country Codes Scan the bar code corresponding to the keyboard type This setting applies only to the USB HID Keyboard Emulation device Note Whe...

Страница 56: ...53 French Canadian Windows 2000 XP French Canadian Windows 95 98 Spanish Windows Italian Windows Swedish Window UK English Windows Japanese Windows ASCII Portuguese Brazilian Windows...

Страница 57: ...Delay Medium Delay 20 msec Long Delay 40 msec USB CAPS Lock Override This option applies only to the HID Keyboard Emulation device When enabled the case of the data is preserved regardless of the sta...

Страница 58: ...ices bar codes containing at least one unknown character are not sent to the host and an error beep sounds For HID Keyboard Emulation devices the bar code characters up to the unknown character are se...

Страница 59: ...Category and value chosen by the user Enable Disable Function Key Mapping ASCII values under 32 are normally sent as a control key sequence When this parameter is enabled the keys in bold are sent in...

Страница 60: ...is enabled on the keyboard This inversion is done regardless of the current state of the keyboard s Caps Lock state Disable Simulated Caps Lock Enable Simulated Caps Lock Convert Case When enabled th...

Страница 61: ...1 A CTRL A 1002 B CTRL B 1003 C CTRL C 1004 D CTRL D 1005 E CTRL E 1006 F CTRL F 1007 G CTRL G 1008 H CTRL H BACKSPACE1 1009 I CTRL I HORIZONTAL TAB1 1010 J CTRL J 1011 K CTRL K 1012 L CTRL L 1013 M C...

Страница 62: ...RL Y 1026 Z CTRL Z 1027 A CTRL ESC1 1028 B CTRL 1029 C CTRL 1030 D CTRL 6 1031 E CTRL 1032 Space Space 1033 A 1034 B 1035 C 1036 D 1037 E 1038 F 1039 G 1040 H 1041 I 1042 J 1043 K 1044 L 1045 1046 104...

Страница 63: ...6 6 1055 7 7 1056 8 8 1057 9 9 1058 Z 1059 F 1060 G 1061 H 1062 I 1063 J 1064 V 1065 A A 1066 B B 1067 C C 1068 D D 1069 E E 1070 F F 1071 G G 1072 H H 1073 I I 1074 J J 1075 K K 1076 L L 1077 M M 10...

Страница 64: ...S 1084 T T 1085 U U 1086 V V 1087 W W 1088 X X 1089 Y Y 1090 Z Z 1091 K 1092 L 1093 M 1094 N 1095 O _ 1096 W 1097 A a 1098 B b 1099 C c 1100 D d 1101 E e 1102 F f 1103 G g 1104 H h 1105 I i 1106 J j...

Страница 65: ...13 Q q 1114 R r 1115 S s 1116 T t 1117 U u 1118 V v 1119 W w 1120 X x 1121 Y y 1122 Z z 1123 P 1124 Q 1125 R 1126 S 1 The keystroke in bold is sent only if the Function Key Mapping is enabled Otherwis...

Страница 66: ...66 ALT B 2067 ALT C 2068 ALT D 2069 ALT E 2070 ALT F 2071 ALT G 2072 ALT H 2073 ALT I 2074 ALT J 2075 ALT K 2076 ALT L 2077 ALT M 2078 ALT N 2079 ALT O 2080 ALT P 2081 ALT Q 2082 ALT R 2083 ALT S 2084...

Страница 67: ...0 3049 GUI 1 3050 GUI 2 3051 GUI 3 3052 GUI 4 3053 GUI 5 3054 GUI 6 3055 GUI 7 3056 GUI 8 3057 GUI 9 3065 GUI A 3066 GUI B 3067 GUI C 3068 GUI D 3069 GUI E 3070 GUI F 3071 GUI G 3072 GUI H 3073 GUI I...

Страница 68: ...U 3086 GUI V 3087 GUI W 3088 GUI X 3089 GUI Y 3090 GUI Z Note GUI Shift Keys The Apple iMac keyboard has an apple key on either side of the space bar Windows based systems have a GUI key to the left o...

Страница 69: ...t F Keys Keystroke 5001 F1 5002 F2 5003 F3 5004 F4 5005 F5 5006 F6 5007 F7 5008 F8 5009 F9 5010 F10 5011 F11 5012 F12 5013 F13 5014 F14 5015 F15 5016 F16 5017 F17 5018 F18 5019 F19 5020 F20 5021 F21 5...

Страница 70: ...67 USB Numeric Keypad Character Set Numeric Keypad Keystroke 6042 6043 6044 undefined 6045 6046 6047 6048 0 6049 1 6050 2 6051 3 6052 4 6053 5 6054 6 6055 7 6056 8 6057 9 6058 Enter 6059 Num Lock...

Страница 71: ...eypad Keystroke 7001 Break 7002 Delete 7003 PgUp 7004 End 7005 Pg Dn 7006 Pause 7007 Scroll Lock 7008 Backspace 7009 Tab 7010 Print Screen 7011 Insert 7012 Home 7013 Enter 7014 Escape 7015 Up Arrow 70...

Страница 72: ...I hosts send a parameter send command from the host system Hexadecimal parameter numbers are shown in this chapter below the parameter title and options are shown in parenthesis beneath the accompanyi...

Страница 73: ...ers Symbology Default Table Parameter Default UPC EAN UPC A Enable UPC E Enable UPC E1 Disable EAN 8 JAN 8 Enable EAN 13 JAN 13 Enable Bookland EAN Disable Decode UPC EAN JAN Supplementals 2 and 5 dig...

Страница 74: ...o Code 32 Italian Pharmacy Code Disable Code 32 Prefix Disable Set Length s for Code 39 2 to 55 Code 39 Check Digit Verification Disable Transmit Code 39 Check Digit Disable Code 39 Full ASCII Convers...

Страница 75: ...e Convert I 2 of 5 to EAN 13 Disable Discrete 2 of 5 DTF Discrete 2 of 5 Disable Set Length s for D 2 of 5 12 Codabar NW 7 Codabar Disable Set Lengths for Codabar 5 to 55 CLSI Editing Disable NOTIS Ed...

Страница 76: ...14 Enable RSS Limited Enable RSS Expanded Enable Convert RSS to UPC EAN Disable Composite Composite CC C Disable Composite CC A B Disable Composite TLC 39 Disable UPC Composite Mode Always Linked Comp...

Страница 77: ...curity Levels Redundancy Level 1 Security Level 1 Inter character Gap Size Normal Report Version Macro PDF Macro PDF Transmit Decode Mode Symbols Pass through Mode Transmit Macro PDF Control Header Di...

Страница 78: ...e Disable UPC A To enable or disable UPC A scan the appropriate barcode below Enable UPC A Disable UPC A Enable Disable UPC E To enable or disable UPC E scan the appropriate bar code below Enable UPC...

Страница 79: ...e UPC E1 scan the appropriate bar code below Note UPC E1 is not a UCC Uniform Code Council approved symbology Enable UPC E1 Disable UPC E1 Enable Disable EAN 8 JAN 8 To enable or disable EAN 8 JAN 8 s...

Страница 80: ...e or disable EAN 13 JAN 13 scan the appropriate bar code below Enable EAN 13 JAN 13 Disable EAN 13 JAN 13 Enable Disable Bookland EAN To enable disable Bookland EAN scan the appropriate barcode below...

Страница 81: ...nded Enable 378 379 Supplemental Mode to delay only EAN 13 JAN 13 bar codes starting with a 378 or 379 prefix by the supplemental search process All other UPC EAN JAN bar codes are exempt from the sea...

Страница 82: ...79 Decode UPC EAN JAN Only With Supplemental Ignore Supplemental Auto discriminate UPC EAN JAN Supplemental Enable 378 379 Supplemental Mode Enable 978 Supplemental Mode Enable Smart Supplemental Mode...

Страница 83: ...0 Scan the bar code below to set a decode redundancy value Next scan two numeric bar codes in Appendix D Numeric Bar Codes Single digit numbers must have a leading zero To correct an error or change a...

Страница 84: ...to guarantee the integrity of the data Transmit UPC E Check Digit Do Not Transmit UPC E Check Digit Transmit UPC E1 Check Digit The check digit is the last character of the symbol used to verify the i...

Страница 85: ...or transmitting a UPC A preamble to the host device transmit System Character only transmit System Character and Country Code 0 for USA and transmit no preamble Select the appropriate option to match...

Страница 86: ...or transmitting a UPC E preamble to the host device transmit System Character only transmit System Character and Country Code 0 for USA and transmit no preamble Select the appropriate option to match...

Страница 87: ...o match the host system No Preamble DATA System Character SYSTEM CHARACTER DATA System Character Country Code COUNTRY CODE SYSTEM CHARACTER DATA Convert UPC E to UPC A Enable this to convert UPC E zer...

Страница 88: ...eck Digit When disabled UPC E1 decoded data is transmitted as UPC E1 data without conversion Convert UPC E1 to UPC A Enable Do Not Convert UPC E1 to UPC A Disable EAN 8 JAN 8 Extend When enabled this...

Страница 89: ...ting with digit 99 and UPCA EAN 128 Coupon Codes UPCA EAN 13 and EAN 128 must be enabled to scan all types of Coupon Codes Enable UCC Coupon Extended Code Disable UCC Coupon Extended Code Note Use the...

Страница 90: ...To enable or disable Code 128 scan the appropriate bar code below Enable Code 128 Disable Code 128 Enable Disable UCC EAN 128 To enable or disable UCC EAN 128 scan the appropriate bar code below Enab...

Страница 91: ...128 ISBT 128 is a variant of Code 128 used in the blood bank industry Scan a bar code below to enable or disable ISBT 128 If necessary the host must perform concatenation of the ISBT data Enable ISBT...

Страница 92: ...Code 39 Trioptic Code 39 is a variant of Code 39 used in the marking of computer tape cartridges Trioptic Code 39 symbols always contain six characters To enable or disable Trioptic Code 39 scan the...

Страница 93: ...ode 32 Note Code 39 must be enabled for this parameter to function Enable Convert Code 39 to Code 32 Disable Convert Code 39 to Code 32 Code 32 Prefix Scan the appropriate bar code below to enable or...

Страница 94: ...ction scan Cancel barcode Two Discrete Lengths Select this option to decode only Code 39 symbols containing either of two selected lengths Select lengths using the numeric bar codes in Appendix D Nume...

Страница 95: ...oder checks the integrity of all Code 39 symbols to verify that the data complies with specified check digit algorithm Only Code 39 symbols which include a modulo 43 check digit are decoded Enable thi...

Страница 96: ...on Code 39 Full ASCII is a variant of Code 39 which pairs characters to encode the full ASCII character set To enable or disable Code 39 Full ASCII scan the appropriate bar code below Enable Code 39 F...

Страница 97: ...of the triggering symbol See the following pages for further details When the Do Not Buffer Code 39 option is selected all decoded Code 39 symbols are transmitted immediately without being stored in...

Страница 98: ...character The decoder issues a short hi lo hi beep The decoder erases the transmission buffer No transmission occurs Clear Buffer Note The Clear Buffer contains only the dash minus character In order...

Страница 99: ...t read results in an overflow of the transmission buffer The decoder indicates that the symbol was rejected by issuing three long high beeps No transmission occurs The data in the buffer is not affect...

Страница 100: ...symbols with 14 characters scan Code 93 One Discrete Length then scan 1 followed by 4 To correct an error or to change the selection scan Cancel barcode Two Discrete Lengths Select this option to dec...

Страница 101: ...ceded by a leading zero To correct an error or change the selection scan Cancel barcode Any Length Scan this option to decode Code 93 symbols containing any number of characters within the decoder s c...

Страница 102: ...ic Bar Codes For example to decode only Code 11 symbols with 14 characters scan Code 11 One Discrete Length then scan 1 followed by 4 To correct an error or to change the selection scan Cancel on barc...

Страница 103: ...scan 0 4 1 and 2 single digit numbers must always be preceded by a leading zero To correct an error or change the selection scan Cancel barcode Any Length Scan this option to decode Code 11 symbols co...

Страница 104: ...it check for two check digits or disable the feature To enable this feature scan the bar code below corresponding to the number of check digits encoded in the Code 11 symbols Disable One Check Digit T...

Страница 105: ...this option to decode only I 2 of 5 symbols containing a selected length Select the length using the numeric bar codes in Appendix D Numeric Bar Codes For example to decode only I 2 of 5 symbols with...

Страница 106: ...change the selection scan Cancel barcode Any Length Scan this option to decode I 2 of 5 symbols containing any number of characters within the decoder capability Note Due to the construction of the I...

Страница 107: ...r the specified Uniform Symbology Specification USS or the Optical Product Code Council OPCC check digit algorithm Disable USS Check Digit OPCC Check Digit Transmit I 2 of 5 Check Digit Scan the appro...

Страница 108: ...character I 2 of 5 codes to EAN 13 and transmit to the host as EAN 13 To accomplish this the I 2 of 5 code must be enabled and the code must have a leading zero and a valid EAN 13 check digit Convert...

Страница 109: ...ne Discrete Length and then scan 1 followed by 4 To correct an error or to change the selection scan Cancel barcode Two Discrete Lengths Select this option to decode only D 2 of 5 symbols containing e...

Страница 110: ...ction of the D 2 of 5 symbology it is possible for a scan line covering only a portion of the code to be interpreted as a complete scan yielding less data than is encoded in the bar code To prevent th...

Страница 111: ...ppendix D Numeric Bar Codes For example to decode only Codabar symbols with 14 characters scan Codabar One Discrete Length then scan 1 followed by 4 To correct an error or to change the selection scan...

Страница 112: ...scan 0 4 1 and 2 single digit numbers must always be preceded by a leading zero To correct an error or change the selection scan Cancel barcode Any Length Scan this option to decode Codabar symbols co...

Страница 113: ...ble this feature if the host system requires this data format Note Symbol length does not include start and stop characters Enable CLSI Editing Disable CLSI Editing NOTIS Editing When enabled this par...

Страница 114: ...llowed by 4 To correct an error or to change the selection scan Cancel barcode Two Discrete Lengths Select this option to decode only MSI symbols containing either of two selected lengths Select lengt...

Страница 115: ...he construction of the MSI symbology it is possible for a scan line covering only a portion of the code to be interpreted as a complete scan yielding less data than is encoded in the bar code To preve...

Страница 116: ...Two MSI Check Digits bar code to enable verification of the second check digit See MSI Check Digit Algorithm for the selection of second digit algorithms One MSI Check Digit Two MSI Check Digits Trans...

Страница 117: ...k Digit Algorithm Two algorithms are possible for the verification of the second MSI check digit Select the bar code below corresponding to the algorithm used to encode the check digit MOD 10 MOD 11 M...

Страница 118: ...stnet To enable or disable US Postnet scan the appropriate bar code below Enable US Postnet Disable US Postnet US Planet To enable or disable US Planet scan the appropriate bar code below Enable US Pl...

Страница 119: ...r disable UK Postal scan the appropriate bar code below Enable UK Postal Disable UK Postal Transmit UK Postal Check Digit Select whether to transmit UK Postal data with or without the check digit Tran...

Страница 120: ...le Japan Postal scan the appropriate bar code below Enable Japan Postal Disable Japan Postal Australian Postal To enable or disable Australia Postal scan the appropriate barcode below Enable Australia...

Страница 121: ...scan the appropriate bar code below Enable Dutch Postal Disable Dutch Postal Transmit US Postal Check Digit Select whether to transmit US Postal data with or without the check digit Transmit US Postal...

Страница 122: ...RSS 14 RSS Expanded and RSS Limited The limited and expanded versions have stacked variants Scan the appropriate bar code below to enable or disable each variant of RSS RSS 14 Enable RSS 14 Disable RS...

Страница 123: ...coding a single zero as the first digit and report the bar code as EAN 13 For bar codes beginning with two or more zeros but not six zeros this parameter strips the leading 0100 and reports the bar co...

Страница 124: ...er F0h 55h Scan a bar code below to enable or disable Composite bar codes of type CC C Enable CC C Disable CC C Composite CC A B Scan a bar code below to enable or disable Composite bar codes of type...

Страница 125: ...122 Composite TLC 39 Scan a bar code below to enable or disable Composite bar codes of type TLC 39 Enable TLC39 Disable TLC39...

Страница 126: ...es regardless of whether a 2D symbol is detected Select UPC Always Linked to transmit UPC bar codes and the 2D portion If 2D is not present the UPC bar code does not transmit If Auto discriminate UPC...

Страница 127: ...ep Mode To select the number of decode beeps when a composite bar code is decoded scan the appropriate bar code Single Beep after both are decoded Beep as each code type is decoded Double Beep after b...

Страница 128: ...mulation Mode for UCC EAN Composite Codes Select whether to enable or disable this mode Enable UCC EAN Code 128 Emulation Mode for UCC EAN Composite Codes Disable UCC EAN Code 128 Emulation Mode for U...

Страница 129: ...PDF417 To enable or disable PDF417 scan the appropriate bar code below Enable PDF417 Disable PDF417 Enable Disable MicroPDF417 To enable or disable MicroPDF417 scan the appropriate bar code below Enab...

Страница 130: ...ls are transmitted with one of the following prefixes C1 if the first codeword is 903 907 912 914 915 C2 if the first codeword is 908 or 909 C0 if the first codeword is 910 or 911 If disabled they are...

Страница 131: ...To enable or disable Data Matrix scan the appropriate barcode below Enable Data Matrix Disable Data Matrix Maxicode To enable or disable Maxicode scan the appropriate bar code below Enable Maxicode D...

Страница 132: ...increase the decoder s aggressiveness decreases Select the redundancy level appropriate for the bar code quality Redundancy Level 1 The following code types must be successfully read twice before bein...

Страница 133: ...s Code Type Code Length MSI Plessey 4 characters or less D 2 of 5 8 characters or less I 2 of 5 8 characters or less Codabar 8 characters or less Redundancy Level 4 The following code types must be su...

Страница 134: ...curity in decoding most in spec bar codes Security Level 1 Select this option if misdecodes occur This default setting should eliminate most misdecodes Security Level 2 Select this option if Security...

Страница 135: ...arger than the maximum size allowed preventing the decoder from decoding the symbol If this problem occurs scan the Large Intercharacter Gaps parameter to tolerate these out of specification bar codes...

Страница 136: ...Symbols Transmit Any Symbol in Set Buffer All Symbols User Scans Beep T Beep T Beep T Last Macro PDF in set Decode Beep Y Decode Beep Y Decode Beep Y Any Macro PDF in set except last Decode Beep Y Dec...

Страница 137: ...nsmits data from each Macro PDF symbol as decoded regardless of the sequence although some error handling is performed When selecting this mode enable Transmit Macro PDF Control Header Also use the be...

Страница 138: ...00000 725 120 343 The five digits after the 928 are the segment index or block index and 725 120 343 is the file ID Enable this when selecting Transmit Any Symbol in Set No Particular Order for the Ma...

Страница 139: ...ameter only affects the data portion of a Macro PDF symbol transmission the Macro PDF Control Header if enabled is always sent with GLI formatting GLI Protocol None Flush Macro Buffer This flushes the...

Страница 140: ...ter title and options are shown in parenthesis beneath the accompanying bar codes Note Most computer monitors allow scanning the bar codes directly on the screen When scanning from the screen is sure...

Страница 141: ...fault Parameters for all user preferences hosts symbologies and miscellaneous default parameters Miscellaneous Scanner Options Default Table Parameter Default Transmit Code ID Character None SSI Prefi...

Страница 142: ...g more than one code type In addition to any single character prefix already selected the Code ID character is inserted between the prefix and the decoded symbol Select no Code ID character a Symbol C...

Страница 143: ...t number i e four barcodes from Appendix D Numeric Bar Codes that corresponds to that value To correct an error or change a selection scan Cancel barcode Note To use Prefix Suffix values first set the...

Страница 144: ...ar codes corresponding to the desired format If using this parameter do not use ADF rules to set the prefix suffix To set values for the prefix and or suffix see Prefix Suffix Values Data As Is DATA S...

Страница 145: ...roke value See the ASCII Character Set table for the currently installed host interface for the desired value To select a FN1 substitution value via bar code menus 1 Scan the bar code below Set FN1 Su...

Страница 146: ...de below to select whether or not to transmit a No Read message When enabled the characters NR are transmitted when a bar code is not decoded When disabled if a symbol does not decode nothing is sent...

Страница 147: ...ired A dirty window may affect scanning accuracy Never use any abrasive material or solvents on the window Do not spray water or other cleaning liquids directly onto the window Remove dirt by wiping g...

Страница 148: ...er Volume High Handheld hands free scanner Level Trigger Modes Scan module Presentation Power Mode Low Power Time Delay to Low Power Mode 1 0 Sec Decode Session Timeout 9 9 Sec Timeout Between Decodes...

Страница 149: ...0 top 0 left 479 bottom 639 right Image Resolution Full JPEG Image Options Quality JPEG Quality Value 65 JPEG Size Value 40 41K Image File Format Selection JPEG Bits per Pixel BPP 8 BPP Signature Capt...

Страница 150: ...p Bit Select 1 Stop Bit Data Bits 8 Bit Check Receive Errors Enable Hardware Handshaking None Software Handshaking None Host Serial Response Time out 2 Sec RTS Line State Low RTS Beep on BEL Disable I...

Страница 151: ...ng Disable Simulated Caps Lock Disable Convert Case None UPC EAN UPC A Enable UPC E Enable UPC E1 Disable EAN 8 JAN 8 Enable EAN 13 JAN 13 Enable Bookland EAN Disable Decode UPC EAN JAN Supplemental 2...

Страница 152: ...Enable ISBT 128 Enable Code 39 Code 39 Enable Trioptic Code 39 Disable Convert Code 39 to Code 32 Italian Pharmacy Code Disable Code 32 Prefix Disable Set Length s for Code 39 2 to 55 Code 39 Check D...

Страница 153: ...2 of 5 14 I 2 of 5 Check Digit Verification Disable Transmit I 2 of 5 Check Digit Disable Convert I 2 of 5 to EAN 13 Disable Discrete 2 of 5 DTF Discrete 2 of 5 Disable Set Length s for D 2 of 5 12 C...

Страница 154: ...stal Enable Transmit US Postal Check Digit Enable RSS Reduced Space Symbology RSS 14 Enable RSS Limited Enable RSS Expanded Enable Convert RSS to UPC EAN Disable Composite Composite CC C Disable Compo...

Страница 155: ...l 1 Intercharacter Gap Size Normal Report Version Macro PDF Macro PDF Transmit Decode Mode Symbols Pass through Mode Transmit Macro PDF Control Header Disable Escape Characters None Flush Macro PDF Bu...

Страница 156: ...153 Non SSI Suffix 1 Value Non SSI Suffix 2 Value CR LF CR LF Scan Data Transmission Format Data as is FN1 Substitution Values Set Transmit No Read Message Disable...

Страница 157: ...8 EAN 13 B Code 39 Code 32 C Codabar D Code 128 E Code 93 F Interleaved 2 of 5 G Discrete 2 of 5 or Discrete 2 of 5 IATA H Code 11 J MSI K UCC EAN 128 L Bookland EAN M Trioptic Code 39 N Coupon Code...

Страница 158: ...155 P03 US Postnet P04 US Planet P05 Japan Postal P06 UK Postal P08 Dutch Postal P09 Australian Postal P09 UK Postal...

Страница 159: ...r Code Type A Code 39 Code 39 Full ASCII Code 32 C Code 128 Coupon Code 128 portion d Data Matrix E UPC EAN Coupon UPC portion e RSS Family F Codabar G Code 93 H Code 11 I Interleaved 2 of 5 L PDF417...

Страница 160: ...7 3 4 0 No option specified at this time Always transmit 0 Trioptic Code 39 Example A Trioptic bar code 412356 is transmitted as X0412356 0 Standard data packet no Function code 1 in first symbol pos...

Страница 161: ...ly 2 Five digit supplement data only 4 EAN 8 data packet UPC EAN Example A UPC A bar code 012345678905 is transmitted as E00012345678905 0 No options specified at this time Always transmit 0 Bookland...

Страница 162: ...te 92DEC has been doubled in transmission 1 Reader set to follow the ECI protocol Extended Channel Interpretation All data characters 92DEC are doubled PDF417 Micro PDF417 2 Reader set for Basic Chann...

Страница 163: ...Symbol in Mode 2 or 3 ECI protocol implemented in secondary message 0 Model 1 symbol 1 Model 2 symbol ECI protocol not implemented 2 Model 2 symbol ECI protocol implemented 3 Model 2 symbol ECI protoc...

Страница 164: ...161 Appendix C Sample Bar Codes Code 39 123ABC UPC EAN UPC A 100 EAN 13 100...

Страница 165: ...162 Code 128 12345678901234567890123456789012345678901234 Interleaved 2 of 5 12345678901231 RSS 14 Note RSS 14 must be enabled to read the bar code below 7612341562341 PDF417...

Страница 166: ...163 Data Matrix Maxicode...

Страница 167: ...164 Appendix D Numeric Bar Codes For parameters requiring specific numeric values scan the appropriately numbered bar code s 0 1 2 3 4 5 6 7...

Страница 168: ...165 8 9 Cancel To correct an error or change a selection scan the bar code below Cancel...

Страница 169: ...Keystroke 1000 U CTRL 2 1001 A CTRL A 1002 B CTRL B 1003 C CTRL C 1004 D CTRL D 1005 E CTRL E 1006 F CTRL F 1007 G CTRL G 1008 H CTRL H BACKSPACE1 1009 I CTRL I HORIZONTAL TAB1 1010 J CTRL J 1011 K CT...

Страница 170: ...1020 T CTRL T 1021 U CTRL U 1022 V CTRL V 1023 W CTRL W 1024 X CTRL X 1025 Y CTRL Y 1026 Z CTRL Z 1027 A CTRL 1028 B CTRL 1029 C CTRL 1030 D CTRL 6 1031 E CTRL 1032 Space Space 1033 A 1034 B 1035 C 10...

Страница 171: ...168 1041 I 1042 J 1043 K 1044 L 1045 1046 1047 o 1048 0 0 1049 1 1 1050 2 2 1051 3 3 1052 4 4 1053 5 5 1054 6 6 1055 7 7 1056 8 8 1057 9 9 1058 Z 1059 F 1060 G 1061 H 1062 I 1063 J...

Страница 172: ...1064 V 1065 A A 1066 B B 1067 C C 1068 D D 1069 E E 1070 F F 1071 G G 1072 H H 1073 I I 1074 J J 1075 K K 1076 L L 1077 M M 1078 N N 1079 O O 1080 P P 1081 Q Q 1082 R R 1083 S S 1084 T T 1085 U U 1086...

Страница 173: ...170 1087 W W 1088 X X 1089 Y Y 1090 Z Z 1091 K 1092 L 1093 M 1094 N 1095 O _ 1096 W 1097 A a 1098 B b 1099 C c 1100 D d 11 E e 11 F f 11 G g 11 H h 11 I i 1106 J j 1107 K k 1108 L l 1109 M m...

Страница 174: ...13 Q q 1114 R r 1115 S s 1116 T t 1117 U u 1118 V v 1119 W w 1120 X x 1121 Y y 1122 Z z 1123 P 1124 Q I 1125 R 1126 S 1 The keystroke in bold is sent only if the Function Key Mapping is enabled Otherw...

Страница 175: ...2066 ALT B 2067 ALT C 2068 ALT D 2069 ALT E 2070 ALT F 2071 ALT G 2072 ALT H 2073 ALT I 2074 ALT J 2075 ALT K 2076 ALT L 2077 ALT M 2078 ALT N 2079 ALT O 2080 ALT P 2081 ALT Q 2082 ALT R 2083 ALT S 2...

Страница 176: ...I 0 3049 GUI 1 3050 GUI 2 3051 GUI 3 3052 GUI 4 3053 GUI 5 3054 GUI 6 3055 GUI 7 3056 GUI 8 3057 GUI 9 3065 GUI A 3066 GUI B 3067 GUI C 3068 GUI D 3069 GUI E 3070 GUI F 3071 GUI G 3072 GUI H 3073 GUI...

Страница 177: ...U 3086 GUI V 3087 GUI W 3088 GUI X 3089 GUI Y 3090 GUI Z Note GUI Shift Keys The Apple iMac keyboard has an apple key on either side of the space bar Windows based systems have a GUI key to the left o...

Страница 178: ...175 PF Key Standard Default Table PF Keys Keystroke 40 PF 1 40 PF 2 40 PF 3 40 PF 4 40 PF 5 40 PF 6 40 PF 7 40 PF 8 40 PF 9 40 PF 10 40 PF 11 40 PF 12 40 PF 13 40 PF 14 40 PF 15 40 PF 16...

Страница 179: ...Keystroke 5001 F 1 5002 F 2 5003 F 3 5004 F 4 5005 F 5 5006 F 6 5007 F 7 5008 F 8 5009 F 9 5010 F 10 5011 F 11 5012 F 12 5013 F 13 5014 F 14 5015 F 15 5016 F 16 5017 F 17 5018 F 18 5019 F 19 5020 F 20...

Страница 180: ...177 Numeric Key Standard Default Table Numeric Keypad Keystroke 6042 6043 6044 Undefined 6045 6046 6047 6048 0 6049 1 6050 2 6051 3 6052 4 6053 5 6054 6 6055 7 6056 8 6057 9 6058 Enter 6059 Num Lock...

Страница 181: ...ed Keypad Keystroke 7001 Break 7002 Delete 7003 Pg Up 7004 End 7005 Pg Dn 7006 Pause 7007 Scroll Lock 7008 Backspace 7009 Tab 7010 Print Screen 7011 Insert 7012 Home 7013 Enter 7014 Escape 7015 Up Arr...

Отзывы: