background image

4

CAUTION

1. The high-pressure outlets (HP Ports) are distinctly larger than the 

low-pressure  outlets.    Only  devices  with  fittings,  hoses  and  compo-

nents  designed  for  the  full  tank  pressure  that  the  regulator  will  be 

subjected  to,  such  as  Pressure  Gauges,  are  to  be  installed  in  these 

ports. 

2. During installation, the O-ring hose fittings will seal with hand-tight 

pressure,  but  may  come  loose  during  use  if  not  tightened  carefully 

with  a  small  wrench.    Proper  torque  for  the  hose  fittings  is  40-45 

in  lbs.  (4.5  -  5  N-m)  Excessive  tightening  will  not  help  the  seal  and 

may  damage  the  parts  (see  Low  Pressure  Hose  Installation  Caution 

Statement;  ANSI  American  National  Standard  for  Safety,  paragraph 

9.3.1).

WARNING

Extreme cold conditions such as those found under ice, requires special-

ized training and procedures.  Do not attempt these activities unless you 

are fully qualified and properly equipped to do so safely.

NITROX USE

SBA  regulators  are  manufactured  using  materials  suitable  for  use 

with  oxygen  enriched  gases  (i.e.,  Nitrox,  etc.)  providing  the  oxygen 

content does not exceed 40%.  The regulator must be kept “Oxygen 

Clean” and used only with certified clean air mixtures to maintain this 

status.  Once the regulator is used with air not certified to be clean 

for enriched air use, the regulator will have to be cleaned again for 

enriched air use by a certified technician.

Содержание Tiger performance T-310SSL

Страница 1: ......

Страница 2: ...Warnings Serial Number Location Using and Filling the SBA Cylinder Information 2nd Stage Pre Use Check Post Use Care Maintenance Specifications Service Record Notes Pages 1 2 5 11 12 13 14 15 15 16 17 18 Table of Contents ...

Страница 3: ...d seriousness These signal words and their designations are as follows DANGER Indicates an imminently hazardous situation which if not avoided will result in death or serious injury This signal word is to be limited to the most extreme situ ations WARNING Indicates a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION Indicates a potentially hazardo...

Страница 4: ...ed in this manual it will provide you with many years of diving enjoyment Safety Information Read these instructions carefully before using your regulator and keep this manual for future reference Following the care and main tenance section at the end of this booklet will help ensure reliable service Serial Number Location The serial number is located on the first stage as shown in Figure 1 below ...

Страница 5: ... training in safe procedures or without observing the prac tices outlined by your training agency for your level of certification is extremely hazardous and could result in serious personal injury or death This owner s manual is in no way meant to be a substitute for the instruction received from a certified training agency 2 SBA regulators must be serviced only by technicians trained and authoriz...

Страница 6: ... see Low Pressure Hose Installation Caution Statement ANSI American National Standard for Safety paragraph 9 3 1 WARNING Extreme cold conditions such as those found under ice requires special ized training and procedures Do not attempt these activities unless you are fully qualified and properly equipped to do so safely NITROX USE SBA regulators are manufactured using materials suitable for use wi...

Страница 7: ...ns such as escape and redundant air supply systems The 1st stage reduces the high pressure air contained in the cylinder to a constant intermediate pressure of approximately 135 psi 9 2 BAR Tiger SBA first stages are designed to do this with outstanding reliability DANGER Using nitrox i e gas mixtures containing oxygen in excess of 21 requires special training and procedures Improper use of nitrox...

Страница 8: ...k pressure using the HP gauge is required the valve hand wheel is turned in a counter clockwise direction until it s fully open This allows the air to move from the lower valve section of the SBA into the upper pressure regulating section and out the LP low pressure ports This also allows air to get from the cylinder to the pressure gauge in the HP port After use the valve hand wheel should be clo...

Страница 9: ... pressure cylinder The 330 FA52 AA Filling Whip Adapter is used when the source of air is a common Scuba tank filling compressor system Fig 3 WARNING To prevent internal cylinder corrosion if any dirt or moisture is seen on the Fill Probe face see Fig 3 when the Cap is removed it must be wiped off or blown off carefully with CLEAN compressed air To ensure a proper fill and to avoid damage to inter...

Страница 10: ...that there is enough pressure no less than 2800 psi 193 Bar for use The SBA cylinder will get hot during the transfilling To ensure a good fill let the small cylinder cool to room temperature before ending the filling process Remove the Cap from the Fill Probe Clean the face of the Fill Probe if necessary Attach the Transfiller by threading it onto the Fill Probe until it s hand tight Fig 4 TURN T...

Страница 11: ...d of the Transfiller to the Yoke Valve in a full Scuba Cylinder Fig 5 Fig 5 Since the Valve Hand wheel on the SBA is fully open Fig 6 the HP pressure gauge on the SBA will now be showing the small cylinder s pressure Fig 6 ...

Страница 12: ...ve The Transfiller bleed valve is opened by twisting the bleed collar pointed to by the red arrow near the 330 6052 part number in Fig 7 above Disconnect the Transfiller from the Fill Probe on the SBA Replace the Cap onto the male threads of the SBA s Fill Probe Close the Valve Hand wheel on the SBA The fill using the Transfiller is now completed A stream ing video on the Zeagle website showing th...

Страница 13: ... Valve Filling Whip on the other end of the Filling Whip Adapter The Valve and Bleed Screw on the Scuba Filling Whip are used in the same manner as the Tank Valve and Bleed Collar on the Transfiller procedure describing in this manual earlier Remember that the working pressure of the SBA s cylinder is 3000 psi 207 Bar DO NOT OVERFILL THE SBA CYLINDER Allow the SBA cylinder to cool to room tem pera...

Страница 14: ...ping is DOT 3AL3000 This means that the cylinder is DOT approved aluminum with a maximum working pressure of 3000 psi The Tiger Performance SBA is design to work safely and efficiently with a 3000 psi cylinder NEVER use the SBA with anything but a 3000 psi cylinder see Fig 10 at left NEVER fill the SBA cylinder above 3000 psi when it cools to room temperture 75 F 24 C 12 At the bottom right of the...

Страница 15: ... on Fig 6 the 320 RG6L 2nd stage is held in the user s mouth by inserting the mouthpiece shown in Fig 10 above When the user inhales air will begin flowing from the 1st stage through the swivel hose into the 2nd stage control valve and into the user s mouth When the user exhales air will automatically be vented out through the Exhaust Port If the user needs to clear or test the SBA the Purge Butto...

Страница 16: ...quantity of air either the exhaust valve is failing to seal properly or there may be a pinhole leak in the mouthpiece or second stage diaphragm Service the SBA if necessary 3 Just before turning on the SBA s Valve Handwheel check to make sure that the all hose connections are tight and that the regulator body is aligned properly with no kinks in the hoses 4 At the beginning of each use turn the Va...

Страница 17: ... the regulator before or during rinsing since this may introduce water into the second stage and the low pressure hose After rinsing thoroughly shake all excess water from the second stage Press the Purge Cover with the SBA s air valve turned on several times to blow the rinse water out of the inner mechanism Allow the entire regulator to air dry before storing For reasons of hygiene equipment sub...

Страница 18: ...ES Flow by Piston Valve Regulator Combination screws directly into a cylinder A FIRST STAGE REGULATOR VALVE MODEL RG6L Compact FEATURES Downstream valve compact diaphragm B SECOND STAGE REGULATOR 1st STAGE WEIGHT 1 5 cu ft CYLINDER WEIGHT 2 0 cu ft CYLINDER WEIGHT 2 5 cu ft CYLINDER WEIGHT 6 0 cu ft CYLINDER WEIGHT INTERMEDIATE PRESSURE LOW PRESSURE PORTS HIGH PRESSURE PORTS MATERIALS Body O rings...

Страница 19: ...17 Service Record Date Service Date SBA first entered Service ...

Страница 20: ...18 Notes The date of purchase and contact information for the source should be written on this page A copy of the issue receipt could also be stapled to this page for future records ...

Страница 21: ...L SBA Survival Breathing Apparatus is distributed exclusively by Tiger Performance Products Inc 525 Bullis Road West Seneca New York 14224 USA Office 1 716 674 8545 Fax 1 716 674 7497 p n 175 1656 Revision Nov 2011 2011 Zeagle Systems Inc ...

Отзывы: