background image

Page

 3 

EBS 

User 

Manual

ZE.01.05.0031 REV. A

TRADEMARK NOTICE 

HUISH OUTDOORS

 and the 

ZEAGLE

 logo are registered or unregistered trademarks of 

Huish 

Outdoors

. All rights are reserved. 

EC TYPE EXAMINATION CONDUCTED BY: 

Products carrying the CE mark have the EC Type Examination conducted by: 

SGS 

F

imko Oy, Takomotie 8, FI-00380 Helsinki, Finland 

Notified Body 0598

All products sold by 

Zeagle

 in the EU (European Union) comply with the following requirements 

where applicable. 

EN12021: This standard specifies the allowable contaminates and component gases that make up 

compressed air. This standard is the equivalent of the USA Compressed Gas Association’s Grade E 

air. Both standards allow very small  amounts of contaminants that are not harmful to breathe, but 

can cause a problem if present in systems using gases with a high percentage of oxygen. 

EN4856

:  The  EBS  is  considered  a  Emergency  Self  Contained  Emergency  Underwater  Breathing 

Apparatus.  A  such,  the  EBS  is  designed  for  user  deployment  and  operation  with  sufficient  notice 

given to the user to deploy the device. 

A “Declaration of Conformity”  

is 

on the 

Huish Outdoors

 website at: 

https://www.huishoutdoors.com/

eu-declarations/declarations-of-conformity/

The 

Zeagle Defender

 EBS is certified as an underwater escape breathing apparatus for use to a 

maximum depth of 4m in water temperatures of 4°C or greater. It is certified that the EBS meets the 

Essential  Health and Safety Requirements in Annex II of Regulation (EU) 2016/425 Personal 

Protective Equipment

This PPE satisfies the requirements for a shallow water underwater escape 

breathing apparatus based on relevant principles and elements of EN4856:20

23

 - Rotorcraft 

Emergency Breathing Systems (EBS), requirements, testing and marking. Also in compliance to 

harmonized standard EN250:2014 - Respiratory Equipment open circuit, self contained, compressed 

air diving apparatus, requirements, testing and marking. 

Содержание DEFENDER EBS 207

Страница 1: ...ual Page 1 ZEAGLE DEFENDER EBS EMERGENCY BREATHING SYSTEM USER MANUAL Huish Outdoors Part PN 350 9200 ZEAGLE DEFENDER EBS 207 BAR SYSTEM PN 350 9210 ZEAGLE DEFENDER EBS 207 BAR SYSTEM w ON OFF ZE 01 0...

Страница 2: ...Page 2 EBS User Manual ZE 01 05 0031 REV A...

Страница 3: ...EBS is considered a Emergency Self Contained Emergency Underwater Breathing Apparatus A such the EBS is designed for user deployment and operation with sufficient notice given to the user to deploy t...

Страница 4: ...able ease of use and maintenance Additional features that include adjustable mouthpiece positions a flexible hose with swivel connections and convenient port connections provide desirable options for...

Страница 5: ...his manual and mastering the skills necessary to operate inspect and maintain it properly Failure to do so could result in a situation whereby the EBS would not be an available resource to assist with...

Страница 6: ...or and valve is threaded into the cylinder to provide a compact assembly It is provided with an onboard pressure gauge an ON OFF port or knob aassembly fill port and low pressure hose with a swivel co...

Страница 7: ...anual EBS User Manual ZE 01 05 0031 REV A The ON OFF port of the integrated valve and first stage must always be in the ON position any time the EBS is in service and ready to be deployed If the valve...

Страница 8: ...with the user s mouth and supply air on demand for breathing See instructions for use in EBS Deployment section of this manual The second stage assembly also provides a location for storage of a nose...

Страница 9: ...NCY SITUATION 1 Use one hand to secure your position at the nearest exit escape route Use your free hand to grasp the EBS second stage regulator and pull out and away from your body to ensure hose is...

Страница 10: ...air flow ceases allowing you to comfortably exhale Air flow to you can be manually activated anytime by pressing the purge feature as long as there is a remaining air supply in the cylinder 5 After y...

Страница 11: ...d properly could create a hazard with a possible risk of serious injury or death Before connecting the Fill Adapter to the Male QD observe the following information When compressed air is introduced i...

Страница 12: ...e a full charge Exceeding the maximum pressure and fill rate could result in damage to the EBS and create a hazardous condition with the possibility of serious injury or death To Fill the EBS cylinder...

Страница 13: ...freshwater to remove sea salt and other contaminates Be sure mouthpiece and exhaust valves are included in flushing operation Following rinsing dip the second stage in a sanitizing bath as prescribed...

Страница 14: ...inder if less than 2 in diameter and less than 12 in length is excepted from volumetric expansion test However the cylinder must be taken out of service if it has been exposed to a temperature greater...

Отзывы: