3. Immediately after you have control of the mouthpiece in your mouth, use your free

hand to locate and grasp the Nose Clip that is secured to the second stage housing.
Pinch the Nose Clip tabs together as shown in the illustration below to open it and place

it over the nose and release. The purpose of the Nose Clip is to block entry of water into

the nose while breathing.  Do not try to breathe through the nose while submerged.

4. Note that the EBS is designed to deliver air only when you attempt to inhale. When you

stop inhaling, air flow ceases allowing you to comfortably exhale. Air flow to you can be

manually activated anytime by pressing the purge feature as long as there is a
remaining air supply in the cylinder.

5. After you reach the surface and have access to air, discontinue use of the EBS. Once

the EBS has been deployed for either an emergency or training it must be removed

from service, no longer available for emergency use until after it has been recharged or
received periodic maintenance.

CYLINDER FILLING GUIDELINES 

Connection to a compressed air supply to charge the EBS requires a specific Filler Adapter.  It 

is a compressor accessory for the air supply facility and is not supplied * as part of the EBS 
assembly.  

EBS 

User 

Manual

ZE.01.05.0031 REV. A

Содержание DEFENDER EBS 207

Страница 1: ...ual Page 1 ZEAGLE DEFENDER EBS EMERGENCY BREATHING SYSTEM USER MANUAL Huish Outdoors Part PN 350 9200 ZEAGLE DEFENDER EBS 207 BAR SYSTEM PN 350 9210 ZEAGLE DEFENDER EBS 207 BAR SYSTEM w ON OFF ZE 01 0...

Страница 2: ...Page 2 EBS User Manual ZE 01 05 0031 REV A...

Страница 3: ...EBS is considered a Emergency Self Contained Emergency Underwater Breathing Apparatus A such the EBS is designed for user deployment and operation with sufficient notice given to the user to deploy t...

Страница 4: ...able ease of use and maintenance Additional features that include adjustable mouthpiece positions a flexible hose with swivel connections and convenient port connections provide desirable options for...

Страница 5: ...his manual and mastering the skills necessary to operate inspect and maintain it properly Failure to do so could result in a situation whereby the EBS would not be an available resource to assist with...

Страница 6: ...or and valve is threaded into the cylinder to provide a compact assembly It is provided with an onboard pressure gauge an ON OFF port or knob aassembly fill port and low pressure hose with a swivel co...

Страница 7: ...anual EBS User Manual ZE 01 05 0031 REV A The ON OFF port of the integrated valve and first stage must always be in the ON position any time the EBS is in service and ready to be deployed If the valve...

Страница 8: ...with the user s mouth and supply air on demand for breathing See instructions for use in EBS Deployment section of this manual The second stage assembly also provides a location for storage of a nose...

Страница 9: ...NCY SITUATION 1 Use one hand to secure your position at the nearest exit escape route Use your free hand to grasp the EBS second stage regulator and pull out and away from your body to ensure hose is...

Страница 10: ...air flow ceases allowing you to comfortably exhale Air flow to you can be manually activated anytime by pressing the purge feature as long as there is a remaining air supply in the cylinder 5 After y...

Страница 11: ...d properly could create a hazard with a possible risk of serious injury or death Before connecting the Fill Adapter to the Male QD observe the following information When compressed air is introduced i...

Страница 12: ...e a full charge Exceeding the maximum pressure and fill rate could result in damage to the EBS and create a hazardous condition with the possibility of serious injury or death To Fill the EBS cylinder...

Страница 13: ...freshwater to remove sea salt and other contaminates Be sure mouthpiece and exhaust valves are included in flushing operation Following rinsing dip the second stage in a sanitizing bath as prescribed...

Страница 14: ...inder if less than 2 in diameter and less than 12 in length is excepted from volumetric expansion test However the cylinder must be taken out of service if it has been exposed to a temperature greater...

Отзывы: