97 / 103
Identification: MD-AL-GI-00
Rev. 1.1 of 12/03/2021 - Application: GID
User’s Manual 1PH 1100TL-3300TL-V3
Rev. 1.1 12/03/2021
Figure 71 - Irregular communication status between the adapter and remote server
-
Check that the router has access to the network and that the connection is stable; check that a PC can
access the Internet
Check that port 80 of the router is open and enabled to send data.
It is advisable to check the brand and model of the home router you are trying to connect to the
Ethernet adapter; some router brands may have closed communication ports. In this case, contact
the customer service of the router’s manufacturer and ask them to open port 80 (direct from the
network to external users).
10.3.
4G adapter
The ZCS 4G adapters are sold with a virtual SIM integrated into the device with data traffic fee included
for10 years, which is adequate for the proper transmission of data to monitor the inverter.
In order to monitor the inverter, the RS485 communication address must be set to 01 directly from the
display.