Zaxcom RX-12R                                                                                                                       System Menu 

Receiver Configure Menu 

The receiver configure menu is where each of the 6 QRX212 receiver modules are 
set up from. Once in the receiver configure menu individual receiver modules can 
be accessed by pressing the corresponding number key on the numeric keyboard. 
In each receiver configuration menu the status of each transmitter will be shown. 
This is the same configuration that is in the home screen.  
 
 

RX Mode 

From the RX mode each individual QRX212 module can be set to single or dual mode and can be powered off. 

Mode 

 

Single - The QRX212 module is set to receive a single transmitter. 

 

Dual - The QRX212 module is set to receive signal from two transmitters 

Power 

The power to each QRX212 module can be toggled on and off from the power setting.  

 

Frequency 

This is where the frequency of the QRX212 is manually adjusted from. To set the frequency highlight the 
receiver that will be adjusted, then rotate the menu encoder knob, or press the desired frequency on the 
numeric keypad.  

 

Transmitter Gain 

If the RX-12R is connected to an IFB200 the gain for each transmitter can be remotely adjusted from here and 
will be sent over ZaxNet to the transmitters. 

 

Unit Code 

This is where the ZaxNet unit code for each module is set. The unit code on each QRX212 receiver must match 
the unit code set in the corresponding transmitter for the remote frequency and gain commands to be sent to 
the proper transmitter. Each receiver and transmitter pair must have its own unique unit code. The unit code 
number can be set to any number between 1 and 99.  

 

Output Type 

The output type sets what audio signal the individual QRX212 module will output. Each module can be set to 
output audio as either an analog signal or an AES signal. This setting will determine what is outputted on the 
bottom DB25 connector “AES AND ANALOG OUT”. If this is set to analog the DB25 will output the b side of each 
receiver QRX212 receiver module. If this is set to AES, when used with the optional combiner board (not 
currently available) the DB25 will mirror the top DB25 connector. 

 

Tone 

Each QRX212 module has its own tone generator. Turning tone on will output tone from the TA5 connector 
at -20dBFS allowing for the levels to be calibrated at the mixer or recorder. 

 

Содержание RX-12RR

Страница 1: ...1 USER MANUAL Published August 2017 Firmware Version 1 24 Zaxcom RX 12RR QRX212 Module Streamlined Reception...

Страница 2: ...ODE ERROR BOOKMARK NOT DEFINED TONE 9 CENTER FREQUENCY SET 10 SCAN MENU 11 CENTER FREQUENCY 11 MARKER 11 FREQUENCY LIST AUTO PICK 12 HOW TO USE AUTO PICK 12 ENCRYPTION 13 SETTINGS MENU 14 FAN SPEED ER...

Страница 3: ...DIGITAL OUT OF TA5 ERROR BOOKMARK NOT DEFINED DC POWER IN HIROSE HR10A 7P 4 PIN MALE 18 SERIAL CONNECTOR USB RS 485 19 Nomad or QRX 19 IFB200 or TRX900 Camera Link Error Bookmark not defined UPDATING...

Страница 4: ...3 5mm TRS The headphone output can be used to monitor the A side of each module To select the module to monitor press the numeric key that corresponds to the module number 6 Enter Key 7 Menu Encoder K...

Страница 5: ...onnector is used to interface with an IFB200 to send ZaxNet remote control commands to the transmitters 8 USB connector Standard USB type A cable Used to connect the RX 12R with a PC or Mac that is ru...

Страница 6: ...m RX 12R Inserting the QRX212 Modules 6 Inserting the QRX212 Modules Rear view of the QRX212 Module Up to 6 QRX212 modules slide into the RX 12R When inserting the modules make sure the arrows pointin...

Страница 7: ...each receiver The meters show the amount of RF signal being received The signal level is visually displayed in the ramp shaped RF meter icon As the shading increases from the left to the right the mor...

Страница 8: ...Zaxcom RX 12R System Menu 8 System Menu To access the system menu press the MENU encoder knob...

Страница 9: ...the RX 12R is connected to an IFB200 the gain for each transmitter can be remotely adjusted from here and will be sent over ZaxNet to the transmitters Unit Code This is where the ZaxNet unit code for...

Страница 10: ...MHz operating range the center frequency should be set to the middle of that range Therefore the best performance of the RX 12R will be frequencies chosen 17 5MHz above and 17 5MHz below the center fr...

Страница 11: ...ditional scans can be performed to show more of the spectrum the RX 12R will remember the previous scans and add the new scan to those When in the scan menu pressing the number 1 key will zoom out sho...

Страница 12: ...so Auto Pick can change the frequency of any receiver s How to use Auto Pick 1 Select a receiver by rotating the menu encoder knob 2 Press the encoder knob to select the receiver That will put a green...

Страница 13: ...only listened to it if it has the same matching encryption code entered When the codes do not match all that will be heard is white noise Each individual QRX212 module will share the same encryption...

Страница 14: ...ted Serial Port Mode Serial port mode assigns what equipment the RS422 port on the RX 12R will communicate with When the serial port mode is set to remote the RX 12R will display data to an external P...

Страница 15: ...e RX 12R firmware Debug Bits The debug bits are a factory diagnostic setting and should stay set to 0 Allow Logging Allow logging will turn on the logging feature which will allow the RX 12R to log wa...

Страница 16: ...t DB25 When output type is set to Analog RECEIVER MODULE B Side Output DB25 PIN Analog 1 20 7 Analog 2 6 18 Analog 3 17 4 Analog 4 3 15 Analog 5 2 14 Analog 6 1 13 Ground pins 5 8 11 16 19 22 25 When...

Страница 17: ...Zaxcom RX 12R Pin Configuration 17 Analog Out XLR XLR Out on RX 12R XLR into Mixer PIN 1 GROUND PIN 2 SIGNAL PIN 3 SIGNAL...

Страница 18: ...5 on RX 12R TA5 in IFB200 PIN 1 Ground PIN 2 No Connection PIN 3 No Connection PIN 4 PIN 4 PIN 5 PIN 5 DC power in Hirose HR10A 7P 4 Pin Male Hirose 4 Pin DC Power Source PIN 1 Negative Ground PIN 2 N...

Страница 19: ...Pin Configuration 19 Serial Connector To communicate with Nomad Standard USB Type A to Type A cable To communicate with Oasis RX 12R Oasis WHITE TXP RED RXP GREEN TXM BLACK RXM RED RXP WHITE TXP BLACK...

Страница 20: ...new firmware RX 12RProfile_vX XX bin and copy it to the card Make sure only one BIN file is on the card 3 Remove the cover of the RX 12R 4 With RX 12R powered down insert the micro SD card which cont...

Страница 21: ...the programing transmitter 7 At the transmitter Make sure the transmitter has fully charged batteries installed Proceeded to the send QRX program menu Press the INC key The TRX will indicate that it...

Страница 22: ...updates Download the latest User Manuals from http zaxcom com support updates Submit Technical Questions at http www zaxcom com submit a technical question Submit information for Repair Services at ht...

Страница 23: ...gain input output 4 0dB RF amp noise figure 5dB RF amp IP3 30dB input RF filter band pass 35 MHz RF tuning range 512MHz 698MHz Power 8VDC 18VDC 12VDC nominal 100ma 2 Hirose HR10A 7P 4P LCD screen TFT...

Страница 24: ...Product Limitation of Remedies Your exclusive remedy for any defective Product is limited to the repair or replacement of the defective Product Zaxcom may elect which remedy or combination of remedie...

Страница 25: ...25...

Страница 26: ...interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on...

Отзывы: