4.4.b Pump
Using the config menu of the programming console, the user can configure the follow-
ing functions.
SUBMENU "SET OPTIONS"
1 HOUR COUNTER
- RUNNING:
the counter registers travel time only.
- KEY ON:
the counter registers when the "key" switch is closed.
2 BATTERY CHECK
- ON:
the battery discharge level check is carried out; when the bat-
tery level reaches 10%, an alarm is signalled and the maximum current is reduced to
the half of the programmed value.
- OFF:
the battery discharge level check is carried out but no alarm is
signalled.
Very important:
In the combi system (pump + traction), the battery discharge calculation for the complete
system is carried out by the traction inverter; the information about the pump inverter con-
sumption is sent on the can-bus line from the pump inverter to the traction inverter. So the
correct programmation for the "Battery check" option is :
-
traction inverter:
ON
-
pump inverter:
OFF
3 SET TEMPERATURE
- DIGITAL:
a digital (ON/OFF) motor thermal sensor is connected to B6
(Minifit), A3 (Amp Saab) input.
- ANALOG:
an analog motor thermal sensor is connected to B6 (Minifit), A3
(Amp Saab) (the curve can be customized on a customer request).
- NONE:
no motor thermal sensor switch is connected.
SUBMENU "ADJUSTEMENT"
1 SET BATTERY TYPE: selects the nominal battery voltage;
2 ADJUST BATTERY:
fine adjustment of the battery voltage measured by the control-
ler.
3 ADJUSTMENT #04:
this parameter determines the motor temperature level at which
the “Motor temperature” alarm is signalled. The range is from 70°C to 160°C with
10°C steps. This parameter must be adjusted only if the “Set temperature” (menu
“Set option”) parameter is programmed “Analog”.
4 THROTTLE 0 ZONE:
establishes a deadband in the accelerator input curve (see
also curve below).
5 THROTTLE X POINT:
These parameter change the characteristic of the accelerator
Содержание ZAPIMOS Series
Страница 21: ...Page 21 3 8 AC3 MECHANICAL DRAWING...
Страница 22: ...Page 22 3 9 AC4 MECHANICAL DRAWING...
Страница 23: ...Page 23 3 10 CONNECTION DRAWING TRACTION CONFIGURATION 3 10 a Amp Saab connector...
Страница 24: ...Page 24 3 10 b Molex Minifit connectors...
Страница 25: ...Page 25 3 11 CONNECTION DRAWING PUMP CONFIGURATION 3 11 a Amp Saab connector...
Страница 26: ...Page 26 3 11 b Molex Minifit connectors...
Страница 27: ...Page 27 3 12 CONNECTION DRAWING COMBI CONFIGURATION 3 12 a Amp Saab connector...
Страница 28: ...Page 28 3 12 b Molex Minifit connectors...
Страница 30: ...Page 30 4 3 DESCRIPTION OF STANDARD CONSOLE MENU 4 3 a Traction configuration...
Страница 31: ...Page 31 4 3 b Pump configuration...