Page 18
B8 NAUX
This output can be used for drive the main contactor coil (single
pump configuration) or to drive an auxiliary load (combi configura-
tion)
B9 NHYDRO
Output for driving an hydraulic steering contactor; drives the load to -
Batt. Maximum current: 3A.
B10 2nd SPEED
Input for second speed request; it is active HIGH.
B11 GND
-Batt.
B12 NTHERM
-Batt.
C1 CAN-L
Low level CAN-BUS voltage I/O.
C2 CAN-L-OUT
Low level CAN-BUS voltage I/O.
C3 CAN-H
High level CAN-BUS voltage I/O.
C4 CAN-H-OUT
High level CAN-BUS voltage I/O.
D1 -BATT
-Batt.
D2 MODE
This input allows the customer to select the software for traction or
lifting application.
Configuration:
MODE: Open (not connected)
Traction inverter
MODE: Close (connected with A5)
Pump inverter
E1÷E6
Incremental ENCODER connector (see chapter 3.6).
F1
PCLRXD
Positive serial reception.
F2
NCLRXD
Negative serial reception.
F3
PCLTXD
Positive serial transmission.
F4
NCLTXD
Negative serial transmission.
F5
GND
Negative console power supply.
F6
+12
Positive console power supply.
F7
FLASH
Must be connected to F8 for the Flash memory programming (if
used).
F8
FLASH
Must be connected to F7 for the Flash memory programming (if
used).
Содержание ZAPIMOS Series
Страница 21: ...Page 21 3 8 AC3 MECHANICAL DRAWING...
Страница 22: ...Page 22 3 9 AC4 MECHANICAL DRAWING...
Страница 23: ...Page 23 3 10 CONNECTION DRAWING TRACTION CONFIGURATION 3 10 a Amp Saab connector...
Страница 24: ...Page 24 3 10 b Molex Minifit connectors...
Страница 25: ...Page 25 3 11 CONNECTION DRAWING PUMP CONFIGURATION 3 11 a Amp Saab connector...
Страница 26: ...Page 26 3 11 b Molex Minifit connectors...
Страница 27: ...Page 27 3 12 CONNECTION DRAWING COMBI CONFIGURATION 3 12 a Amp Saab connector...
Страница 28: ...Page 28 3 12 b Molex Minifit connectors...
Страница 30: ...Page 30 4 3 DESCRIPTION OF STANDARD CONSOLE MENU 4 3 a Traction configuration...
Страница 31: ...Page 31 4 3 b Pump configuration...