Page 33
pedal potentiometer. The minimum intensity is established by the "Release braking"
parameter, when the brake pedal is slightly pressed (brake switch close but brake
potentiometer at the minimum). The maximum intensity is established by the "Pedal
braking" parameter when the brake pedal is fully pressed (brake potentiometer at the
maximum). In the middle positions, the electrical braking intensity is a linear function
between minimum and maximum intensity.
- DIGITAL:
The truck does not have a potentiometer installed on the me-
chanical brake pedal, but only a microswitch; when the accelerator pedal is released
and the brake pedal is pushed (brake switch closed), the inverter performs an electri-
cal braking following "Pedal braking" parameter.
8 SET TEMPERATURE
- DIGITAL:
a digital (ON/OFF) motor thermal sensor is connected to B6
(Minifit), A3 (Amp Saab) input.
- ANALOG:
an analog motor thermal sensor is connected to B6 (Minifit), A3
(Amp Saab) (the curve can be customized on a customer request).
- NONE:
no motor thermal sensor switch is connected.
SUBMENU "ADJUSTEMENT"
1 SET POT BRK MIN:
records the minimum value of braking pedal potentiometer
when the braking pedal switch is closed; the procedure is similar to the "Program
Vacc" function (see chapter 5.4). This procedure must be carried out only if the
"Pedal braking" option is programmed as "Analog".
2 SET POT BRK MAX:
records the maximum value of braking pedal potentiometer
when the braking pedal is fully pressed; the procedure is similar to the "Program
Vacc" function (see chapter 5.4). This procedure must be carried out only if the
"Pedal braking" option is programmed as "Analog".
3 SET BATTERY TYPE: selects the nominal battery voltage;
4 ADJUST BATTERY:
fine adjustment of the battery voltage measured by the control-
ler.
5 ADJUSTMENT #04:
this parameter determines the motor temperature level at which
the “Motor temperature” alarm is signalled. The range is from 70°C to 160°C with
10°C steps. This parameter must be adjusted only if the “Set temperature” (menu
“Set option”) parameter is programmed “Analog”.
6 THROTTLE 0 ZONE:
establishes a deadband in the accelerator input curve (see
also curve below).
7 THROTTLE X POINT:
These parameter change the characteristic of the accelerator
input curve.
8 THROTTLE Y POINT:
These parameter change the characteristic of the accelerator
input curve.
Содержание ZAPIMOS Series
Страница 21: ...Page 21 3 8 AC3 MECHANICAL DRAWING...
Страница 22: ...Page 22 3 9 AC4 MECHANICAL DRAWING...
Страница 23: ...Page 23 3 10 CONNECTION DRAWING TRACTION CONFIGURATION 3 10 a Amp Saab connector...
Страница 24: ...Page 24 3 10 b Molex Minifit connectors...
Страница 25: ...Page 25 3 11 CONNECTION DRAWING PUMP CONFIGURATION 3 11 a Amp Saab connector...
Страница 26: ...Page 26 3 11 b Molex Minifit connectors...
Страница 27: ...Page 27 3 12 CONNECTION DRAWING COMBI CONFIGURATION 3 12 a Amp Saab connector...
Страница 28: ...Page 28 3 12 b Molex Minifit connectors...
Страница 30: ...Page 30 4 3 DESCRIPTION OF STANDARD CONSOLE MENU 4 3 a Traction configuration...
Страница 31: ...Page 31 4 3 b Pump configuration...