AF6ZP0AL - COMBIAC0 & ACE0 - User Manual
Page - 39/79
4) THROTTLE X POINT
This parameter, together with the THROTTLE Y POINT, changes the
characteristic of the accelerator input curve : when the accelerator is de-
pressed to X point per cent, the corresponding truck speed is Y point per cent
of the Maximum truck speed. The relationship between the accelerator
position and the truck speed is linear between the THROTTLE 0 ZONE and
the X point and also between the X point and the maximum accelerator
position but with two different slopes.
5) THROTTLE Y POINT
This parameter, together with the THROTTLE X POINT, changes the
characteristic of the accelerator input curve (see also paragraph 13.5): when
the accelerator is de-pressed to X point per cent, the corresponding truck
speed is Y point per cent of the Maximum truck speed. The relationship
between the accelerator position and the truck speed is linear between the
THROTTLE 0 ZONE and the X point and also between the X point and the
maximum accelerator position but with two different slope.
6) BAT. MIN ADJ.
Adjust the lower level of the battery charge table (Level 0 to 9).
7) BAT.
MAX
ADJ.
Adjust the upper level of the battery charge table (Level 0 to 9).
8) LOAD HM FROM MDI
When set On, the HourMeter of the Controller is transferred and recorded on
the HourMeter of the MDI CAN, connected to CAN BUS network.
9) CHECK
UP
DONE
It can be ON/OFF. If it is ON it is possible to reset the last maintenance hour-
counter and the “CHECK UP NEEDED” warning.
10) CHECK UP TYPE
It specifies the handling of the CHECK UP NEEDED warning:
-
NONE:
No CHECK UP NEENED warning
-
OPTION#1: CHECK UP NEENED warning shown on the hand set and
MDI/DISPLAY after 300 hours
-
OPTION#2: Equal to OPTION#1 but Speed reduction after 340 hours
-
OPTION#3: Equal to OPTION#2 but the truck definitively stops after 380
hours
11) ) MIN LIFT
This parameter stores the minimum voltage of lifting potentiometer output
connected to CNA#30. The min value acquisition is done closing the Lift SW
and bringing the potentiometer in its min output position.
12) MAX LIFT
This parameter stores the maximum voltage of lifting potentiometer output
connected to CNA#30. The max value acquisition is done closing the Lift SW
and bringing the potentiometer in its max output position.
13) MIN LOWER
%. This parameter stores the minimum voltage of lowering potentiometer
output connected to CNA#30. The min value acquisition is done closing the
DESCENT SW (DI1) and bringing the potentiometer in its min output
Содержание COMBI AC0
Страница 27: ...AF6ZP0AL COMBIAC0 ACE0 User Manual Page 27 79 8 DRAWINGS 8 1 Mechanical drawing ...
Страница 28: ...Page 28 79 AF6ZP0AL COMBIAC0 ACE0 User Manual 8 2 Connection drawing ACE0 ...
Страница 29: ...AF6ZP0AL COMBIAC0 ACE0 User Manual Page 29 79 8 3 Connection drawing CombiAC0 ...
Страница 33: ...AF6ZP0AL COMBIAC0 ACE0 User Manual Page 33 79 10 3Description of the console menu 10 3 1 ACE0 COMBIAC0 Menu ...