21
Hints for test centres
Before starting any test it is necessary to fill completely with salt the salt container and with rinse aid the rinse
aid dispenser.
Test standard
EN 50242
Reference programme:
Bio 50°C with prewash
Load:
12 standard place settings
Rinse aid selector:
position 5
Detergent dosage :
25 g in the dispenser
5 g in the SID
UI48
US66
Arrangement
upper basket
Arrangement
lower basket
UI69
Arrangement
cutlery basket
US67
Arrangement
knife basket
DIMENSIONS
Width
59.6 cm
Height with worktop
81.8 - 87.8 cm
Max depth
59 cm
Max depth with open door
111.4 cm
ELECTRICAL CONNECTION
Voltage
230 V - 50 Hz
MOTOR RATING DURING WASH
200 W
POWER OF HEATING ELEMENT
2100 W
OVERALL POWER
2300 W
WATER SUPPLY PRESSURE
Minimum
50 kPa (0.5 bar)
Maximum
800 kPa (8 bar)
CAPACITY
12 place settings
Technical specifications
Содержание ZD 699