background image

 

Page 1 of 22 

10/11/2009 

 

 
 

TECHNICAL MANUAL  

DISH WASHER 

 

“ADVANCE”  

 
 
 

 
 

 

CSI INSTALACIONES

Summary of Contents for Advance

Page 1: ...Page 1 of 22 10 11 2009 TECHNICAL MANUAL DISH WASHER ADVANCE C S I I N S T A L A C I O N E S...

Page 2: ...FORM The platform used for controlling the low range ADVANCE dishwasher front loading top loading and glasswasher is shown below ADVANCE Serigraphy Main control card Temperature Card Card Assembly C S...

Page 3: ...ip switches for configuring the appliance Inputs TT PC Thermostat indicating whether the established tank temperature has been reached On the other hand for a Clinic appliance that is an appliance wit...

Page 4: ...t have descaler o If DIP2 1 The appliance has descaler Therefore if B2 is pressed for 3 seconds the descaler cycle is activated o DIP3 Time o If DIP1 0 DIP3 0 P1 90 P2 120 P3 180 o If DIP1 0 DIP3 1 P1...

Page 5: ...HER GLASSWASHER MODELS TOP LOADING AD 120 ON OFF ON OFF AD 120 HY ON OFF ON ON P1 55 P2 80 P3 120 DIP1 ON when the door is closed or the cover lowered the dishwasher starts DIP1 OFF when the door is c...

Page 6: ...Page 6 of 22 10 11 2009 DIPS ON OFF C S I I N S T A L A C I O N E S...

Page 7: ...off Note Depending on the model this button may have the auxiliary function of descaler or drainage pump B2 Button P1 o If this button is pressed once the dishwasher will start to wash with programme...

Page 8: ...e is not washing this LED is off B3 Button P2 o If this button is pressed once the dishwasher starts to wash with programme 2 L3 LED P2 o If the appliance is washing this LED remains lit It is also li...

Page 9: ...ressing the button again for 3 seconds will deactivate it L4 LED P3 o If the appliance is washing this LED remains lit It is also lit if the appliance is in PAUSE mode i e if the door has been opened...

Page 10: ...starting the countdown to zero when the machine stops If the door is opened at any moment the appliance and the countdown will PAUSE and start operating normally again when the door is stopped When a...

Page 11: ...ng start or in middle This is indicated by a one impulse train 2 If PT 1 Tank not full for 6 minutes and BD 0 Not draining This is indicated by a two impulse train 3 If PT 0 Tank full for 1 minute and...

Page 12: ...Page 12 of 22 10 11 2009 C S I I N S T A L A C I O N E S...

Page 13: ...Page 13 of 22 10 11 2009 C S I I N S T A L A C I O N E S...

Page 14: ...Page 14 of 22 10 11 2009 C S I I N S T A L A C I O N E S...

Page 15: ...Page 15 of 22 10 11 2009 C S I I N S T A L A C I O N E S...

Page 16: ...Page 16 of 22 10 11 2009 C S I I N S T A L A C I O N E S...

Page 17: ...2 MAX Controllable 39 AD 21B AD 21C 2 4 Kg cm2 28 56psi 220 240V 1N 50 60Hz 2 8 2 3 14 400x40 0 2 Fixed 15 2 5 42 Water Voltage Power kW Basket Duratio Capacit Consumptio Net MODEL inlet power Resist...

Page 18: ...i 65 AD 72 200 400 kPa 2 4 Kg cm2 28 56 psi 30x 25 380 415V 3N 220V 3 220 240V 1N 50 60Hz 6 2 8 6 65 500x50 0 90 180 25 2 7 69 Water Power W Basket Consumptio Net MODEL inlet Resistor Max square rinse...

Page 19: ...Page 19 of 22 10 11 2009 NOTES C S I I N S T A L A C I O N E S...

Page 20: ...Page 20 of 22 10 11 2009 NOTES NOTES C S I I N S T A L A C I O N E S...

Page 21: ...Page 21 of 22 10 11 2009 NOTES C S I I N S T A L A C I O N E S...

Page 22: ...Page 22 of 22 10 11 2009 C S I I N S T A L A C I O N E S...