28
GAS CONVERSION
Ensure that the cooker is disconnected from the
electricity and gas supply before this procedure is
carried out.
Your cooker is designed to work with natural,
propane or butane gas. It is not designed for
butane or propane air.
The LPG conversion kit is available from your
Service Force Centre and must be fitted by a
Corgi Registered engineer.
For changing the gas type it is necessary to:
·
replace the nozzles (hob);
·
adjust the minimum level (hob);
·
check the gas connection;
Replace the nozzles of the hob burners
Every appliance has spare nozzles for every type
of gas. The whole length of every nozzle is
marked in millimetres on the nozzle.
Hob burners
·
Remove the pan support;
·
Remove the caps and the burner crowns;
·
Using a No 7 socket spanner unscrew the
nozzles and replace them with those required
for the type of gas in use (see table no. 1).
·
Reassemble the parts following the same
procedure in reverse.
These burners do not need any primary air
regulation.
Adjustment of minimum level for the hob
burners
The burner is correctly adjusted when the flame is
stable silent and goes out without any noise.
When changing the type of gas check that the
minimum level is correct. The air admission is
correct when the flame is about 4 mm in length.
The top burners do not need adjustment of
primary air.
Check that, turning the knob quickly from the
maximum position to the minimum one, the flame
does not go out.
Hob burners
To adjust the minimum level:
·
Light the burner and set the knob to the
MINIMUM position.
·
Remove the knob.