23
ELECTRICAL CONNECTIONS
Any electrical work required to install
this cooker should be carried out by a
qualified electrician or competent person, in
accordance with the current regulations.
THIS COOKER MUST BE EARTHED.
The manufacturer declines any liability
should these safety measures not be
observed.
This cooker is designed to be connected to a 230V
50Hz AC electrical supply.
Before switching on, make sure the electricity
supply voltage is the same as that indicated on
the cooker rating plate. The rating plate is
located on the oven frame.
The cooker is supplied with a 3 core flexible
supply cord incorporating a 13amp plug fitted. In
the event of having to change the fuse, a 13amp
ASTA approved (BS 1362) fuse must be used.
Should the plug need to be replaced for any
reason, the wires in the mains lead are coloured
in accordance with the following code:
Green and Yellow - Earth
Blue
- Neutral
Brown
- Live
-
Connect the green and yellow (earth) wire to
the terminal in the plug which is marked with
the letter 'E' or the earth symbol or coloured
green and yellow.
-
Connect the blue (neutral) wire to the
terminal in the plug which is marked with the
letter 'N' or coloured black.
-
Connect the brown (live) wire to the terminal
in the plug which is marked with the letter 'L'
or coloured red.
Upon completion there must be not cut, or stray
strands of wire present and the cord clamp must
be secure over the outer sheath.
A cut off plug inserted into a 13 amp
socket is a serious safety (shock) hazard.
Ensure that the cut off plug is disposed of
safely.
Permanent Connection
The electrical connection should be made using
a double pole isolating switch (cooker control
switch) with at least 3mm contact separation in
all poles. The cable must have conductors of
sufficiently high cross-sectional area to prevent
overheating or deterioration.
The switch should be sited within 2m of the
cooker and be easily accessible at all times.
The yellow-green earth wire must not be
interrupted by the switch.
Ensure that the cooker supply cable
does not come into contact with surfaces
with temperatures higher than 50° C.