22
INSTRUCTIONS FOR THE INSTALLER
SAFETY ADVICE
·
Before installation ensure that the local
distribution conditions (gas type and pressure)
and the same as those stated on the rating
plate of the appliance.
·
This appliance must be installed only in a
room with good ventilation.
·
This appliance must not connected to a flu. It
has to be installed and connected in
accordance with the rules in force. Special
attention should be paid to the applicable
disposal concerning ventilation.
·
The adjacent furniture panels have to be heat
proof or protected by such material.
·
The adjusting conditions of this appliance are
mentioned on the rating plate.
Connection to gas supply.
Check that the gas flow and the diameter of the
supply pipe is sufficient to supply all the
appliances of the installation
.
·
Check that all connections are tight.
·
Install an accessible and visible gas tap to
isolate the appliance.
This appliance utilises a threaded ½” gas
cylindrical male fitting according to UNI-ISO
228-1.
To connect the appliance to the gas supply with a
flexible rubber hose, a supplemental hose nipple
fitting is needed which is supplied with the
appliance.
-
Installation of flues and ventilation for gas
appliances of rated input not exceeding 60
kW (1
st
, 2
nd
and 3
rd
family gases) – Part 2
Specification for installation of ventilation
for gas appliances – BS 5440;
-
Gas burning appliances – Part 3 Domestic
cooking appliances burning gas – BS
5386;
-
Specification for installation of low
pressure gas pipe work of up to 20mm
(R1) in domestic premises (2
nd
family gas)
– BS 6891;
-
Pipe threads for tubes and fittings where
pressure-tight joints are made on the
threads (metric dimensions) – BS 21:
1985;
-
Flexible hoses, end fittings and sockets
for gas burning appliances – BS 669;
-
Installation of domestic gas cooking
appliances (1
st
, 2
nd
and 3
rd
family gases) –
BS 6172: 1990;
An adapter to covert the Gas Inlet from ½”
BSP parallel thread to ½” BSP tapered (conical)
thread is supplied, including washers. Ensure this
is correctly fitted on installation
.