23
!
WARNING!
–
For LP. Gas. The pressure must be set
to 29
mbar for use on butane or 37 mbar
for use on
propane.
4.
Turn off the taps, disconnect the pressure
gauge.
5.
Check operation of each hob burner.
Checking the grill
•
Place the grill pan containing the grid, into the grill
compartment. To light the grill burner push in and
hold the control knob, turn it counter clockwise to
grill symbol. Press the ignition button immediately.
Keep the control knob depressed for up to 5
seconds, but no longer than 10 seconds. After this
time release the controls. The flame should remain
alight. If after 10 seconds the burner has not lit,
stop operating the appliance and wait at least 1
minute before attempting a further ignition of the
burner. When the burner has lit release the control
and ignition button.
Checking the hob
•
Fit the burner crowns and caps
ensuring that they
are correctly seated. Fit
the pan supports.
•
To light the hob burner push in and hold the
control
knob, turn to the large flame symbol
(highest
setting). Press the ignition button
immediately. If
the appliance is equipped
with, FSD you can also
check the FSD system
by the following procedure:
keep the
control knob depressed for up to 5
seconds,
but no longer than 10 seconds. After this
time
release the controls. The flame should remain
alight. If after 10 seconds the burner
has not lit,
stop operating the appliance and
wait at least 1
minute before attempting a
further ignition of the
burner. When the
burner has lit release the control
and ignition
button, adjust the setting as required.
Turn
off the hob and wait 1 minute. Turn the hob
control knob to the large flame symbol (highest
setting). DO NOT depress or attempt to
ignite the
burner. No gas should flow.
Checking the main oven
1
.
To light the main oven burner push in and
hold
the control knob, turn to gas mark 9
Press the
ignition button immediately.
Keep the control knob
depressed for up to
5 seconds, but no longer than
10 seconds.
After this time release the controls
.
The battery
After unpacking, install the battery in the battery
box
as explained below. The battery is placed
in the
document bag.
1.
The battery is located on the left hand side
of the
front plinth.
2.
To gain access to the battery, open the
main oven
door and lift up the battery
holder lid.
3.
Fit the new battery ensuring (+) terminal is
next to
the (+) sign on the battery.
4.
Close the lid of the battery holder.
Pressure testing
1
.
The Rapid injector is used as a pressure
test
point.
2
.
Connect the pressure gauge to the Rapid
injector.
3.
Check the supply pressure by turning the
Rapid
burner on and one other hob burner
full on and
light the appropriate burner.
The pressure should be either:
–
For Natural Gas 20mbar