Burner
Normal
power
Reduced
power
Type of gas
Pressure
Injector di-
ameter
Usage
kW
kW
mbar
mm
g/h
3,00
0,72
Propane G31
37
0,88
214,24
Gas Connection
Choose fixed connections or use a flexible pipe
in stainless steel in compliance with the regula-
tion in force. If you use flexible metallic pipes,
be careful they do not come in touch with mo-
bile parts or they are not squeezed.
Flexible nonmetal pipes connection
If it is possible to easily and fully control the gas
connection, you can use a flexible pipe. You
must tightly attach the flexible pipe by clamps.
To install, use a pipe holder. Make sure that you
tightly attach the pipe holder to the gasket, and
then continue with the gas connection. The
flexible pipe is correct when:
– It cannot become hotter than room tempera-
ture or higher than 30 °C.
– It is no longer than 1500 mm.
– It does not compress.
– It is not subject to traction or torsion.
– It does not make contact with sharp edges or
corners.
– You can easily examine it in order to check
its condition.
To preserve the flexible pipe, you must regularly
check if:
– It does not show cracks, cuts or burn marks
on the two ends and its length.
– The material is correctly elastic and not hard-
ened.
– The fastening clamps are not rusted.
– It is not expired.
If you can see one or more defects, do not re-
pair the pipe, but replace it.
Important!
After installation is complete, use a
soapy solution and never a flame to see if you
sealed all the pipe fittings perfectly.
The gas supply ramp is on the rear side of the
control panel.
Warning!
Before gas connection
disconnect the mains plug from the
mains socket or switch off the fuse in the
fuse box. Close the primary valve of the
gas supply.
A
B C
D
E
A) Gas connection point (only one point is ap-
plicable for appliance)
B) Gasket
C) Adjustable connection
D) LPG pipe holder
E) Natural Gas pipe holder
The appliance is set to default gas, to
change the setting choose pipe holder
from the list. Always use the gasket sealing.
Adjustment to different types of gas
Warning!
Let only an authorized person
do the adjustment to different types of gas.
This appliance is for operation with natural
gas.
With the correct injectors, you can also operate
it with liquid gas.
Warning!
Before replacing the injectors,
make sure that the gas knobs are in the
Off position and disconnect the appliance from
the electrical supply. Let the appliance cool off
fully. There is a risk of injury.
16
www.zanussi.com
Содержание ZCG560N