4. INSTALLATION
CITIZEN EP70
15
F [mm] G [mm] H [mm] I [mm] L [mm] M [mm] N [mm]
CITIZEN EP70
single-chamber
535
455
350
990
455
455
693
CITIZEN EP70
double-chamber
535
455
590
990
455
455
693
*
N.B. When the unit is consigned without top, it is supplied with a
vapor exhaust connector (for Ø155mm tubing)
Check that the exhaust system creates an adequate draft for
expelling vapors and cooking odors (see paragraph 4.5).
4.6
Checks before starting up
After completing installation of the unit a series of checks must be
carried out, listed as follows:
1. check that the various disassembled parts have been assembled:
- vapour exhaust connection, in the case of module without top (see Fig.
4.4 position C)
- condensation exhaust (see Fig 4.4 position D)
- refractory surfaces (see Fig 4.6)
2. check the power cable
3. check that the control panel is working
4. If present, check that the ventilation hood is working
N.B. Insert the refractory surfaces with the corrugated surfaces
facing downwards.
Fig.4.6 Positioning the slabs of refractory material
Содержание CITIZEN EP 70/4+4
Страница 2: ......
Страница 25: ...8 MAINTENANCE CITIZEN EP70 25 Fig 8 1 Electrical diagram Citizen EP70 single chamber at 400 Vac 3 N version...
Страница 26: ...8 MAINTENANCE 26 CITIZEN EP70 Fig 8 2 Electrical diagram Citizen EP70 single chamber at 230 Vac 3 version...
Страница 27: ...8 MAINTENANCE CITIZEN EP70 27 Fig 8 3 Electrical diagram Citizen EP70 single chamber at 230 Vac 1 N version...
Страница 28: ...8 MAINTENANCE 28 CITIZEN EP70 Fig 8 4 Electrical diagram Citizen EP70 double chamber at 400 Vac 3 N version...
Страница 31: ...8 MAINTENANCE CITIZEN EP70 31 Figure 8 7 Exploded view...
Страница 33: ...8 MAINTENANCE CITIZEN EP70 33 Figure 8 8 Exploded view of electrical parts...
Страница 34: ...8 MAINTENANCE 34 CITIZEN EP70 Figure 8 9 Exploded view of electrical parts...