background image

REMOTE GSM SWITCH GRM-10 

MANUAL INSTRUCTION

ZAMEL 

Sp. z o.o.

ul. Zielona 27, 43-200 Pszczyna, Poland

Tel. +48 (32) 210 46 65, Fax +48 (32) 210 80 04

www.zamelcet.com

, e-mail: [email protected]

The device is designed for single-

phase installation and must be installed 

in accordance with standards valid in a 

particular country. The device should 

be connected according to the details 

included in this operating manual. 

Installation, connection and control should be car-

ried out by a qualified electrician staff, who act in 

accordance with the service manual and the device 

functions. In case of casing dismantling an electric 

shock may occur, and the guarantee is lost then. 

Before installation make sure the connection cables 

are not under voltage. The cruciform head screw-

driver 3,5 mm should be used to instal the device. 

Improper transport, storage, and use of the device 

influence  its  wrong  functioning.  It  is  not  advisable 

to instal the device in the following cases: if any 

device part is missing or the device is damaged or 

deformed. In case of improper functioning of the de-

vice contact the producer.

CAUTION

APPEARANCE

FEATURES

TECHNICAL PARAMETERS

DESCRIPTION

●  Remote  control  of  the  electrical  de-

vices by means of commands (in-

coming phone connection, text mes-

sage) sent from a mobile phone,

●  Comfortable  control  of  difficult  ac-

cess devices (air conditioning, heat-

ing, etc.),

●  Two  relay  outputs  with  the  load  ca-

pacity of 16 A,

●  Operation is optically signalled (pow-

er supply, relay status, GSM modem 

status)

●  Low power consumption, a possibility 

of continuous operation.

The GRM-10 device is designed to 

realise simple control and notice opera-

tions. The operations are carried out by 

means of the GSM network. The control-

ler has two independent outputs with a 

maximum load capacity of 16 A / 250 V 

AC. Two digital inputs allow for a link with 

the alarm control panels. The RS485 in-

terface in connection with the RXM-01 

translator gives a possibility to control 

EXTA FREE system receivers with the 

help of a mobile phone and messages 

that are defined by the user. The number 

of  operation  modes  and  configuration 

options make the GRM-10 a very useful 

device for simple home automation and 

industrial systems. The GRM-10 device 

is made in a three-MOD casing and is 

designed for mounting in switchboards 

on a TH35 rail.

GRM-10

Nominal input rated voltage: 230 V AC 50 / 60 Hz

Input voltage tolerance: -15 ÷ +10 %

Nominal power consumption: 1,5 W

GSM frequency: 900/1800/1900 MHz

Operating range: restricted by the GSM network

Supply voltage optical signalling: LED diode (green)

GSM status signalling: LED diode (yellow)

Output number: 2

Output status signalling: 2 x LED diode

Output relays parameters: 2 x NO 16 A / 250 V AC AC1 4000 VA

Input number: 2

Input type: Digital - pot4 V

Interfaces: RS485 MODBUS - A,B,C terminals; USB;

PK1, PK2 push-buttons

RS485 transmission signalling: LED diode

Position on RS485 bus: only MASTER

Ambient temperature range: -10 ÷ +55 

o

C

Operating position: free

Casing mounting: TH35 rail

Casing protection degree: IP20 (PN-EN 60529)

Protection class: II

Overvoltage category: II

Pollution degree: 2

Dimensions: 3-modular casing

Weight: 163 g

Reference standard: PN-EN 60950-1:2007; PN-EN 55024:2000;

PN-EN 61000-4-4  

The symbol means selective 

collecting of electrical and electronic 

equipment. It is forbidden to put the 

used equipment together with other 

waste.

plik: inst_ext_pl_grm-10_gb | modyfikacja: 03.06.2013

Input terminals

RS485 Interface

Power supply signalling

GSM range signalling

Relay 1 (LEDP1)

status signalling

SIM card input

Relay 2 (LEDP2)

status signalling

GSM antenna

RS-485 transmission

signalling

MICRO USB input

Power supply terminals

Output terminals

PK1, PK2 push-buttons

Содержание GRM-10

Страница 1: ...puts with a maximum load capacity of 16 A 250 V AC Two digital inputs allow for a link with the alarm control panels The RS485 in terface in connection with the RXM 01 translator gives a possibility t...

Страница 2: ...he GRM 10 application on the PC 1 After switching off the power supply voltage connect the GRM 10 device to the PC by means of a USB Micro B USB cable and pressing the PK2 push button 2 Start the GRM...

Страница 3: ...pes Remarks MANUAL By means of PK1 PK2 push buttons on the front panel Bistable ON OFF Time TIME Gate GATE Times for TIME and GATE modes are adjusted during con figuration CLIP By calling to the devic...

Страница 4: ...essively entered phone numbers preceded by 48 The text messages will be sent to these numbers The confirma tions refer to the changed output status and occurences on IN1 IN2 inputs The maximum of numb...

Страница 5: ...ng a text message MESSAGE with a defined content X number of an input output 1 input output IN1 OUT1 2 input output IN2 OUT2 tx f the output must be active for a period of time TIME then the parameter...

Страница 6: ...s is 0x01 The address is important for a larger number of RXM 01 operating independently on a single object 3 Following the description of the PC add programme particular push but tons sent by the RXM...

Страница 7: ...X ON Electronics Authorized Distributor Click to view similar products for LED Lighting Fixture Accessories category RZB03 ASM10 ORDBYE115 STR21230V AS223 ORAE1336G ORAE1373 ORWE501 ORWE504 ORWE514...

Отзывы: