background image

Connect  the  device  to  single-

phase  mains,  according  to  appli-

cable  standards.  The  connection 

method  is  shown  in  this  manual. 

The activities related to the instal-

lation, connection and adjustment 

should  be  performed  by  qualified 

electricians, familiar with the user manual and func-

tions of the device. Removing the housing leads to 

the loss of guarantee and creates the risk of electric 

shock. Before starting installation, ensure connec-

tion lines are not supplied with voltage. For instal-

lation, use a Philips screwdriver with a diameter of 

up to 3.5 mm. The correct operation of the device 

can be affected by transport, storage and opera-

tion.  Installing  the  device  is  not  recommended  in 

the following cases: no components, damage to the 

equipment or deformities. In the event of malfunc-

tioning, contact the manufacturer.

CAUTION

CONNECTION

INSTALLATION

NOTES

The  SRM-22  controller  is  designed  for  installa-

tion in switch cabinets on TH35 bar. Receiver’s 

body  takes  up  two  modules.  It  is  required  to 

connect an antenna for correct operation. If you 

need  to  install  the  antenna  outside  the  switch 

cabinet  (applies  mainly  to  metal  switchboards), 

you can use external antenna ANT-01 with a 3 m 

cable. The antenna with an SMA type connector.

1. Disconnect the supply circuit with a fuse, an 

over current circuit breaker or an isolator con-

nected to the corresponding circuit.

2. Check  the  voltage-free  status  of  the  power 

cords with a suitable instrument.

3. Connect the wires to the terminals according 

to the connection diagram.

4. Install the device on a TH bar in the switch-

gear.

5. Activate the supply circuit and check for cor-

rect operation.

1. The controller works with 230 VAC single-phase motors with limit switches or overload switches. Up 

to two motors can be connected to the controller. Do not connect more than one motor to a single 

output on the SRM-22. You must observe maximum rated output load — 350 W (2 A) for loads in class 

AC3.

2. It is not recommended to install drivers in metal switch gears due to the fact that metallic material has 

very strong dampening features of radio waves which could result in a significant reduction of range.

3. It is recommended that the shutter connected to the specific output of the controller during installation 

and programming be in the extreme position (fully opened or closed). If not, after programming the 

remote or pairing a control unit with the controller, it is necessary to make several shutter movements 

to place it in the extreme position (top or down).

4. You can use inputs of SRM-22 controller to connect spring-action shutter switch for wired control. 

By default, the controller works with double spring-action shutter switches. In order to connect single 

switches, connect inputs ▼ and ▲ assigned to the shutter or using mobile application set “Single 

shutter switch” (then you can connect the switch to input ▼ or ▲ to the shutter).

CAUTION: If you connect input terminals ▼, ▲ for the shutter to connect a single switch, you 

must reapply power supply to the SRM-22.

By connecting the input terminals of one shutter, the inputs of the second shutter will automatically start 

operating as inputs for working with single switches (after physically connecting the inputs, you cannot 

have one shutter controlled with single shutter switch and the second with double switch). Such switch 

arrangement  is  possible  only  when  inputs  are  configured  from  mobile  app  working  with  EXTA  LIFE 

controller.

5. During the installation make sure that the receiver is not exposed to direct water impact or operation 

in increased humidity environment. The temperature at the installation site should be from -10 to 

+55°C.

6. The SRM-22 controller is designed for indoor installation. In case of outdoor installation, place the 

receiver in an additional sealing box and efficiently seal against water penetration.

7. After installing the SRM-22 controller, check it for proper operation. When using EXTA LIFE system 

transmitters for control, you must first program them with a receiver (see Programming the transmit-

ters). To work with the controller, the receiver must be properly paired with the controller (see Re-

ceiver registration in the EXTA LIFE system). Local inputs in default operating mode are immediately 

ready to use.

REMOTE SOFTWARE UPDATE

The SRM-22 receiver has a built-in bootloader for remote updating of software from EXTA LIFE app. 

Updating is possible only for receivers paired with controller and can be carried out by the user with 

administrator’s rights. To perform update, you must download the latest version of software from ex-

talife.pl and move it to an SD card in the controller; read the manual “Updating software in EXTA LIFE 

receivers”. The manual can be downloaded from extalife.pl.
The  current  software  version  of  the  SRM-22  receiver  is  shown  on  “Version  information”  tab. After 

pressing the “Update” button, you are sending information to the controller which switches the receiver 

into software update mode. The latest version of software is sent to the receiver from the control-

ler. During the update, the receiver and controller are switched to service frequency and cannot be 

controlled. After a successful update, the applicable information about is sent from receiver to the 

controller and signalled in mobile app.
If the update procedure fails for some reason, then it will be shown as a receiver with update error on 

the controller. The receiver loses 

its original functionality (which is 

signalled  by  the  green  STATUS 

LED  blinking  continuously  every 

1 s). Then, selecting “Version in-

formation”  in  the  app  for  the  re-

ceiver, then it will be possible to 

repeat the update process.

CAUTION: Do not delete the 

receiver with an update error 

from the controller’s resources.

WARRANTY CARD

There is 24 months guarantee on the product

Salesman stamp and signature, date of sale

1.  ZAMEL provides a two-year warranty for its products. 

2.  The ZAMEL warranty does not cover: a) mechanical defects resulting from transport, loading / unloading or other circumstances  

b) defects resulting from incorrect installation or operation of ZAMEL products; c) defects resulting from any changes 

made by CUSTOMERS or third parties, to products sold or equipment necessary for the correct operation of products 

sold; d) defects resulting from force majeure or other aleatory events for which ZAMEL is not liable; e) power supply 

(batteries) to be equipped with a device in the moment of sale (if they appear); 

3.  All complaints in relation to the warranty must be provided by the CUSTOMER in writing to the retailer after discovering 

a defect.; 

4.  ZAMEL will review complaints in accordance with existing regulations.; 

5.  The way a complaint is settled, e.g. replacement of the product, repair or refund, is left to the discretion of ZAMEL. 

6.  Guarantee does not exclude, does not limit, nor does it suspend the rights of the PURCHASER resulting from the 

discrepancy between the goods and the contract.

L

L

N

N

Hardware 

(physical) 

connection of 

double shutter 

switches

Hardware 

(physical) 

connection of 

single shutter 

switches

Hardware (physical) connec-

tion of single shutter switch for 

controlling shutter 1
Shutter 2 inputs are automatically 

configured for operation with 

single switch

Отзывы: