ZALMAN LQ1000 Скачать руководство пользователя страница 2

English Version

Please read this manual thoroughly before installation. 

The specifications of this product and its components may change without prior notice to improve
performance. 

Visit our website and watch the Z-Machine LQ1000 installation

video for an installation overview. 

Installation Notes

1. Check the condition of the product and its components before installation. If there is a

problem with the product and/or its  components, please contact the retailer for
replacement. 

2. Keep this unit away from heat sources such as direct sunlight, as well as from water, oil,

and humidity. Place the unit on a flat, stable, and  well-ventilated area. 

3. Do not drop or subject the unit to excessive force. 
4. Do not mix any contaminants with the coolant when filling. It may cause product failure or

corrosion. 

5. Check the manual when connecting cables. Incorrect connections can lead to fire resulting

from short circuiting. 

6. Check for leaks on the Water Blocks and Tubes before installation. 
7. Preparing the necessary tools (Needle-Nose Pliers, Scissors) will ease the installation

process.

Operational Notes

1. Check to see if the DC cables are properly connected before use. 
2. Avoid inserting any objects into the system while the power is ON. It may be harmful for the

user and product. 

3. If the coolant is not circulating properly or if the pump’s flow rate becomes too low for other

reasons, the red LED will begin to flicker with an alarm sound. Immediately turn the system
OFF and contact the place of purchase. 

4. Must use the provided coolant. Regularly check the amount of coolant and replenish as

needed (replacement cycle of the ZM-G300 coolant is 1 year).

5. If a leak is found, turn off the system immediately and contact the place of purchase. 
6. Do not block the Air Ducts on either side of the product. This can lead to fan failure,

increased noise, or a decrease in product performance. 

7. Make sure that the Water Pump is functioning properly.

Disclaimer

Zalman Tech Co., Ltd. is not responsible for any damages due to external causes, including
but not limited to, improper use, problems with electrical power, accident, neglect, alteration,
repair, improper installation, or improper testing.

Notes

1

2

Содержание LQ1000

Страница 1: ......

Страница 2: ...g the necessary tools Needle Nose Pliers Scissors will ease the installation process Operational Notes 1 Check to see if the DC cables are properly connected before use 2 Avoid inserting any objects i...

Страница 3: ...E1394 Firewire Port x 1 Headphones x 1 MIC x 1 Dimensions L x W x H 125mm X 172mm X 26mm Weight 800g Material Aluminum Alloy Acrylic Coolant Capacity Max 300cc Power Consumption 6W DC 12V Maximum Flow...

Страница 4: ...WB5 5 6 Diagram Part Name Specifications Qty Application L Wrench 3mm 1 Assembly Allen Screw M4 8 4 Outer Chassis Optional Fan Stand Off 4 Optional Fan Install M B Stand Off 12 M B Installation PSU Sc...

Страница 5: ...the FDD Slot require using Fixing Bolts B bolt M3 5 to secure drives 4 2 Pump Bracket Removal To prevent damage to the unit during transport the Pump Bracket is removed Note The Pump Bracket can cause...

Страница 6: ...board s manual before making cable connections Certain motherboards have different configurations for the IEEE1394a USB2 0 and audio connectors from the one shown in the diagram below Please refer to...

Страница 7: ...le forces in the tube by repeatedly opening and closing the side panel Please adjust the Tube length to prevent tension in the Tube 7 If optional VGA Northbridge Water blocks are please repeat the ten...

Страница 8: ...begins circulating Please pour additional coolant up to the Reservoir Window s High Level mark 7 After degassing is complete detach the PSU s power connection Use a coin like object to secure the Rese...

Страница 9: ...the FND Display will flicker If the flickering is observed please check for problems Coolant Flow Rate Gauge Displays the coolant s flow rate in real time Control Knob Controls the Fan Speed and Cool...

Страница 10: ...ra Quiet Operation Improved Power Factor Reduced Harmonics through Active PFC High Efficiency Design and 80 PLUS Certified Supports ATX12V CPU 4 Pin and EPS12V CPU 8 Pin Gold Plated Terminals 16AWG Wi...

Отзывы: