The central unit is equipped with two types of visual alarms:
If the pressure values become at least 7,5% lower or higher than the reference pressure value (compensated), the backlight of the display automatically lightens and the warning icon starts
flashing (see pict. no.1)
If the pressure values become 15% lower or higher than the reference pressure value (compensated), or in case of tyre internal pressure higher than 75°C (167°F), the backlight of the
display automatically lightens, the warning icon starts flashing and the warning led light turns on and off.
In both cases it is not safe to ride the vehicle. It is necessary to stop and check your tyres condition. Either repair the tyre or restore the correct pressure before starting your ride again.
Central unit set-up menu (picture no. 3)
Before entering the set up menu make sure the central unit is completely off. Push and keep on pushing S2 and, at the same time, start the central unit by pushing S1. It is now possible to
scroll the menu pages by shortly pressing the S2 button. To access a specific page of the menu shortly press S1. Once in the menu, if no button is pushed within 30 seconds, the central unit
automatically returns to its normal functions.
All procedures must be completed within their maximum time frame. If this time limit is exceeded, the procedure will be terminated without being completed.
Tyre sensors learning procedure (picture no. 4)
The central unit and the tyre sensor have already been matched by the producer. If the memorization of a new sensor is necessary, follow the procedure described here below:
•
Enter the “1 SL” menu. The icon of the front tyre will start flashing. If you wish to switch to the rear sensor, shortly push S2. Deflate the front tyre until the pressure value is lower than
0,9 bar (13 psi) and higher than 0,4 bar (6 psi).
•
Press S1. The led will shortly flash and the front tyre icon will become fixed. The code of the front tyre sensor has been recognized and stored in the memory.
•
The rear tyre symbol will start flashing. To exit without executing the procedure for the rear tyre press S2.
•
Now follow the same procedure described for the front tyre.
•
Once the procedure has been completed the central unit automatically returns to ACTIVE mode.
Units of measure set up
(picture no. 5)
The units of measure memorized during production for pressure and temperature are “BAR” and “°C”. It is possible to change these into “PSI” and “°F”.
•
Enter the “2 Un” menu.
•
The symbols of the memorized unit of measure will start flashing. Push S1 to confirm these units of measure; your choice will be confirmed by a short flashing of the led. To change
units of measure push S2 and then to confirm your choice by shortly pushing S1; the led will shortly flash.
Memorization of the pressure reference value
The pressure reference value gives a point of reference to the central unit to calculate the warning and alarm thresholds respectively fixed at ±7,5% and ±15% of the memorized pressure
values. This value is compensated according to the temperature: this means that the central unit automatically recalculates the warning and alarm thresholds based on the air temperature
inside the tyre.
Anytime the pressure inside the tyres is intentionally modified (because of a trip with passenger or use of the bike on a race track etc.) it is necessary to update the memorized pressure
reference value. To do this push anytime S2 for more than 2 seconds.
Installation of the device (picture no. 6-7-8)
•
Remove the tyre and the originally equipped valve.
•
Assemble
the sensor-valve unit
of RTS as shown in the pictures;
•
Insert the valve in the hole of the rim and tighten up to 5 Nm;
•
Assemble the tyre. It is important to start assembling the tyre from the side opposite to the valve in order not to squash the sensor under the tyre edge;
•
Proceed in the same way for the second sensor.
If necessary, follow the self-learning procedure indicated in picture no.4. This step must be followed only when one of the originally supplied sensors needs to be replaced. This procedure is
not required when at the first mounting.
After any installation, repeat the memorization procedure for the pressure reference values (page n.)
When the sensor is fixed on the rim and the tyre needs to be demounted, always start bead loosening from the side opposite to the valve. To prevent damages to the electronic device inside
the tyre during bead loosening always keep away from the valve area.
Carefully check that the diameter of the valves supplied in your RTS set is compatible with the hole diameter on your bike rim. RTS is available in different versions to adapt to the several
types of valves available on motorcycles currently produced.
To clean the central unit use a humid (with water only) cleaned cloth. The central unit is completely spray proof, nevertheless do not use under pressure water to clean your motorbike if the
central unit is installed.
RTS is suitable for tubeless (without inner tube) tyres only.
Retrocopertina
Il prodotto deve essere installato solo da personale qualificato
ZADI spa si riserva il diritto di apportare modifiche al prodotto in qualsiasi momento si rendessero necessarie, senza l’obbligo di darne comunicazione.
Product must be installed only by qualified personnel.
ZADI spa reserves the right to modify the content of this manual or the technical characteristics and specifications of the product, at any time, without notice.
Das Produkt darf nur von qualifiziertem Personal eingebaut werden.
Zadi spa behält sich das Recht vor, zu jedem beliebigen Zeitpunkt eventuell erforderliche Änderungen am Produkt vorzunehmen, ohne verpflichtet zu sein, dies bekanntzugeben.
Содержание RTS Bike
Страница 1: ...1 Manuale Istruzioni RCS Bike ITA ENG TED ...
Страница 4: ...Fig 3 Menu 4 Manuale Istruzioni RCS Bike ITA ENG TED ...
Страница 5: ...Fig 4 Self learn 5 Manuale Istruzioni RCS Bike ITA ENG TED ...
Страница 6: ...Fig 5 Units of measure 6 Manuale Istruzioni RCS Bike ITA ENG TED ...
Страница 7: ...Fig 6 Sensor assembly 7 Manuale Istruzioni RCS Bike ITA ENG TED ...
Страница 8: ...Fig 7 Sensor spring spacing 8 Manuale Istruzioni RCS Bike ITA ENG TED ...
Страница 9: ...Fig 8 Central unit mounting options 9 Manuale Istruzioni RCS Bike ITA ENG TED ...
Страница 10: ...Fig 9 Temperature compensation diagram 10 Manuale Istruzioni RCS Bike ITA ENG TED ...