11.1. Front Panel Indicators
Green LED On
The device is powered on and is operating normally.
Green LED Fades In and Out
The device is parked.
Issue a tools parking unpark (T:65) command, or home (T:1) the device.
Green LED Flashes Slowly
The operating conditions of the device are outside of the recommended range.
This will occur when the supply voltage is either over or under the recommended range,
the internal temperature has exceeded the set limit, or the driver has been disabled. Check
the following:
• The input voltage is within the operational range of the device. This can be read
from the device with the get system.voltage command.
• The device temperature is within range. This can be read from the device with the
get system.temperature command.
• The driver is not disabled. If the driver is disabled the result of the warnings
command will contain the FD flag.
Green LED Off
The device is not powered.
Check the supply connections and power adaptor for correct operation.
Red LED On or Flashing.
A critical error has occurred.
Please contact Zaber Technical Support.
Blue LED On or Flashing.
The device has slipped or stalled.
Please see the Slipping and Stalling section below.
Yellow LED Always Off or Flashes but No Reply.
There are communication errors.
Please see the Communication Errors section below.
Содержание X-MCB1 Series
Страница 4: ...III ZABER TECHNOLOGIES INC 17 Product Drawing 18 Specifications 55 56 ...
Страница 49: ...45 ZABER TECHNOLOGIES INC 5 Choose Browse my computer for driver software ...
Страница 50: ...46 ZABER TECHNOLOGIES INC 6 Click the Browse button and select the location where you extracted the driver to ...
Страница 51: ...47 ZABER TECHNOLOGIES INC 7 Click Next ...
Страница 59: ...55 ZABER TECHNOLOGIES INC 17 Product Drawing ...