7
ZABER TECHNOLOGIES INC.
• USB 2.0 Full Speed
• Communications Device Class, Abstract Control Model
• Default Protocol: Zaber ASCII
• Supported Protocols: Zaber ASCII, Zaber Binary
5.1.4. Motor Interface
Pin
Description
1
+5V
2
D Limit Sensor or Encoder Error
3
C Limit Sensor
4
Away Limit Sensor
5
Home Limit Sensor
6
Ground
7
Motor B1
8
Motor A1
9
E5V
10
Encoder A
11
Encoder B
12
Encoder Index
13
Encoder Ground
14
Motor B2
15
Motor A2
NOTE: The limit sensor inputs are pulled up to the internal supply rail and are designed to be
pulled low by an open collector.
NOTE: All sensor and encoder inputs are non-isolated 5V TTL lines.