![Z3 Technology Z3-DM8107-SDI-RPS Скачать руководство пользователя страница 51](http://html2.mh-extra.com/html/z3-technology/z3-dm8107-sdi-rps/z3-dm8107-sdi-rps_user-manual_3093375051.webp)
CONFIDENTIAL
DOC-USR-0030-12
___________________________________________________________________________________________
Z3 Technology, LLC
♦
100 N 8
th
ST, STE 250
♦
Lincoln, NE 68508-1369 USA
♦
+1.402.323.0702
51
12.0
SUMMARY OF OPTIONS
This section lists the different options that are available in the various menus.
12.1
The System Setup Tab
Parameter
Options (default in bold)
Notes
Local IP Address
192.168.x.y
(192.168.81.07)
Sets the IP address of the Z3-DM8107-SDI-RPS.
Note that a “save” of these settings and a reboot
is needed for changes to this value to take
effect.
Local Netmask
255.255.z.w (
255.255.0.0
)
Sets the netmask of the Z3-DM8107-SDI-RPS.
Note that a “save” of these settings and a reboot
is needed for changes to this value to take
effect.
Default Gateway
192.168.a.b (
192.168.0.1
)
Sets the network gateway to use for the Z3-
DM8107-SDI-RPS. Note that a “save” of these
settings and a reboot is needed for changes to
this value to take effect.
Set Device Name
Can use to set the name for Z3-DM8107-SDI-RPS.
Set Password
Can use to assign a password. See “USING THE
PASSWORD FEATURE” on page 49.
update device firmware
See “Method 1: Updating the Image File” on
page 42.
download device logs
Clicking this causes the Z3-DM8107-SDI-RPS to
extract a set of diagnostic logs that can be sent
to Z3 Technology in the event of an issue to be
reported. This file is saved on the PC which the
GUI is being run from.
Display Mode
(Decode Only)
sdi+hdmi
hdmi
sdi
Used to set whether output is on SDI, HDMI, or
both. Note that if the display resolution is
“NTSC” or “PAL”, the display mode must be set
to “sdi.”