It is recommended that you allow for an “exclusion zone” of 0.04" (1 mm) around the
RCM3200 in all directions (except above the RJ-45 plug) when the RCM3200 is incorpo-
rated into an assembly that includes other printed circuit boards. This “exclusion zone”
that you keep free of other components and boards will allow for sufficient air flow, and
will help to minimize any electrical or electromagnetic interference between adjacent
boards. An “exclusion zone” of 0.08" (2 mm) is recommended below the RCM3200
when the RCM3200 is plugged into another assembly using the shortest connectors for
headers J1 and J2. Figure A-2 shows this “exclusion zone.”
Figure A-2. RCM3200 “Exclusion Zone”
0.08
(2)
0.08
(2)
0.6
(16)
1.93
(49.0)
0.6
(16)
J1
J2
Exclusion
Zone
2.725
(69.2)
1.850
(47.0)