background image

28

Sup Controlled, Door Lock V1 Controlled, Door Lock Logging V1 Controlled, Firmware Update V1 Controlled, Indicator
V1 Controlled, Manufacturer Specific V1 Sup Controlled, Meter V3 Controlled, Meter Table V1 Controlled, Multichannel
V3 Controlled, Multichannel Association V2 Controlled, Multicommand V1
Controlled, Multilevel Sensor V6 Controlled, Multilevel Switch V3 Cont Supported, Node Naming V1 Cont
Supported,
Powerlevel V1 Sup Controlled, Protection V2 Controlled, Scene Activation V1 Sup Controlled, Scene Actuator
Conf V1
Controlled, Scene Controller Conf V1 Controlled, Security V1 Supported and Controlled, Sensor Configuration V1 Controlled,
Thermostat Fan
Mode V3 Controlled, Thermostat Fan State V3 Controlled, Thermostats Mode V3 Controlled, Thermostat Operating State V1
Controlled,
Thermostat Setpoint V3 Controlled, Time V2 Sup Controlled, Time Parameter V1 Controlled, User Code V1 Controlled,
Version V2
Sup Controlled, Wakeup V2 Controlled, Z-WavePlus V1 Sup Controlled

Support

Should you encounter any problem, please give us an opportunity to address it before returning this
product. Most questions regarding Z-Wave wireless communication standard can be answered through
the international community at www.z-wave.info

FCC STATEMENT :

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired
operation.
Warning: Changes or modifications not expressly approved by the party responsible for compliance
could void the user's authority to operate the equipment.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates uses and can radiate
radio frequency energy and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:

 

Reorient or relocate the receiving antenna.

 

Increase the separation between the equipment and receiver.

 

Connect the equipment into an outlet on a circuit different from that to which the receiver is

connected.

 

Consult the dealer or an experienced radio/TV technician for help.

FCC Radiation Exposure Statement:

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.
This equipment should be installed and operated with minimum distance 20cm between the radiator &
your body.

Содержание Z-Box

Страница 1: ...y Settings remember your remote access ID and define your remote password This password is used for accessing the controller from outside the home It is shared among all local users in the home If you...

Страница 2: ...es not included which allow the system to continue operation for up to 6 hours depend on battery capacity and application when the power is out We recommend use 2400mA Z Box provide trickle charge to...

Страница 3: ...gs To reset the Network to the default settings press and hold the Main button on top of the Z box for 10 seconds Release the button when the LED quickly flashes red indicating reset Refer to the Dome...

Страница 4: ...PC pads or mobile phones This interface allows managing your smart home equipped with interconnected Z Wave devices It will show every function of the device as one single Element In case a physical...

Страница 5: ...vices are quite complex generating a lot of functions You may want to delete certain elements from the element view This can be done on the elements configuration with the checkbox Permanently delete...

Страница 6: ...ers with admin privileges this dialog also controls the essential access credentials for the remote access using find z wave me User Management This menu item is only available for users with admin pr...

Страница 7: ...icate for the remote access in the future Whenever you access your Z Box within your local network as the first time you will not need a password The Configuration service uses the cloud infrastructur...

Страница 8: ...nt can be suppressed for performance reason if desired In Z Wave all non battery powered device such as the Z Box will act as routers for other devices to form a so called meshed network In case there...

Страница 9: ...le App store or the iOS app store for native apps with the name Z Way The Z Wave Expert UI The Z Wave Expert User Interface is designed for installers technically savvy people and other users that kno...

Страница 10: ...other web based or app based UIs The timing info on the upper right side shows the time on the controller device Its update serves as a heart beat to the system All values shown in the Z Wave Expert...

Страница 11: ...he specific device will react on a Switch All ON or Switch All Off command A green triangle indicates that the device will react to the command shown All actuators can be switched on or off Dimmer and...

Страница 12: ...mind that battery operated device will only respond after the next wakeup Clicking on the table heads reorders the table view of the data Thermostats The thermostat dialog lists all thermostat devices...

Страница 13: ...The date time indicates the time of the last successful communications between the controller and this device either confirmed sending or reception The green checkmark indicates that the device is ali...

Страница 14: ...view of the data Type Info The type info dialog lists all devices of the network and indicates if they support enhanced Z Wave functions such as Security and Z Wave Plus Their Z Wave protocol version...

Страница 15: ...ftware will not automatically recognize the device and load the description record a button Choose Device Description Record allows to do this manually The interview stage line gives information about...

Страница 16: ...ss the devices sets a different minimal or maximal wakeup time In most cases the node id of the controller is the correct setting for the target node id and should not be changed In case this controll...

Страница 17: ...ed with it are shown in the Association tab In case the information is provided either by the device or by the device record stored in the software the meaning of the events is written Otherwise only...

Страница 18: ...ces only channel 0 is shown Clicking on the number opens a dialog showing all internal variables for the channel The next column shows all the command classes exposed by the device Again clicking on t...

Страница 19: ...e and repair the wireless network of the controller Control The network control summarizes all commands needed to manage the network and the controller The page is structured in four boxes The device...

Страница 20: ...n turns the controller into a mode where all security functions are suppressed for the included device Security functions of other devices are not impacted The second box of the page allows creating a...

Страница 21: ...ves such a device from the network configuration The drop down list will only show IDs of failed nodes If this list is empty this is a good sign It is also possible to Replace a Failed node with a new...

Страница 22: ...imary controller of the network to a controller that will be included using the normal inclusion process The controller status dialog shows the mode and its termination The Request NIF from all device...

Страница 23: ...23...

Страница 24: ...e to scan its neighborhood and report back the result to update its own line of the routing table Reorganization The reorganization page controls an algorithm that reorganizes the network relationship...

Страница 25: ...st box offers some deep insight into the dynamics of the controller software It visualizes the job queue of the system Every communication attempt of the controller is queues into a job queue and then...

Страница 26: ...ease information of the Z Way software This information may be needed during support and debugging The controller is a special node in the network but still a node Therefore buttons allow accessing th...

Страница 27: ...roller only able to include new devices Secondary Controller If no SIS is present all other controllers than the primary controller are called secondary Inclusion the process of bringing new Z Wave de...

Страница 28: ...e may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation Warning Changes or modifications not expressly ap...