DCN: 140-01773-01

Page 8

Heat Pump HVAC System

Thermostat Connection

G   Fan 

W1 Aux Heat

Y1 Compressor Stage 1

R   24VAC  Return

C   24VAC Common

Y2 Compressor Stage 2

O    Change Over Valve

For Heat Pump systems, connect the 24R connection 

to either the 24RC or 24RH

Y1

G

Y2

RS2

RS2

RSC

HC

Heat Pump HVAC System Wiring

Thermostat Setup:  
Heat Pump HVAC Systems

To set the HVAC system type, go to the 

Thermostat Info

screen 

and press

Setup

button. 

1. 

Type.

   Set the HVAC System Type:  set to 

Heat Pump

2. 

Fan Type

. Automatically set for heat pump systems.  Ignore this setting.

3. 

C/O type

.  Change Over (reversing) Valve Type.  Heat pumps change from heating to cooling by reversing operation. 

You must configure the thermostat’s changeover valve setting to work correctly with your HVAC system.  
Check your system information to be sure and note the color of original thermostat wire and the terminal it was connected to. 
No matter what the old stat connection was (O or B), connect the wire to the thermostats W2/O terminal.  
The setting of the C/O Type will set the correct system operation.
For change over with cool systems (Orange wire, O terminal): set 

C/O type

to w/cool (most common and default setting)

For change over with heat systems (Brown wire, B terminal): set 

C/O type

to w/heat   

4. 

2nd Stage Heat

.  Enable second stage heating outputs

If you have a single stage heating system, leave this set to 

N

If you have a 2 stage heating system, set to 

Y

to enable. 

5. 

Aux Heat (HP).

   If you have auxiliary heat strips, set this to 

to enable.

6.  

2nd Stage Cool

.  Enable second stage cooling outputs

If you have a single stage cooling system, leave this set to 

N

.

If you have a two stage cooling system, set to 

Y

to enable.

24RC

W1

24RH

W2/O

RS1

RS1

RSC

H1

24C

Cooling 24V

Fan

Cooling stage 1

Cooling stage 2

Remote Sensor 2

Remote Sensor 2

Sensor shield

Humidity Relay Com 

24VAC Com

24V Heating

Aux Heating

Change Over Valve

Remote Sensor 1

Remote Sensor 1

Sensor shield

Humidity Relay 

Remote Outside Sensor

Remote Indoor Sensor 

Shielded cable

Shielded cable

Thermostat back

Note!

  If you get heating 

when you expected cooling, 
change the C/O type to the 
opposite setting.

*

*

* Not used on this version
See Humidity enabled Product TZB45H 

Содержание T100R

Страница 1: ...System Wiring Terminal Marking Meaning Typical Wire Color Record the old thermostat wire connections and terminal marking here C 24VAC Common Blue R 24VAC Return Red G Fan Green W or W1 Heat stage 1 White Y or Y1 Cool stage 1 Yellow W2 Heat stage 2 Orange Y2 Cool stage 2 Black Heat Pump HVAC System Wiring Terminal Marking Meaning Typical Wire Color Record the old thermostat wire connections and te...

Страница 2: ...re the thermostat for the correct HVAC system type You will need to know the following information to correctly configure the thermostat The HVAC setup is in the Mechanical Settings menu screen HVAC system type What type HVAC system do you have Standard or Heat pump For Standard systems Fan Type Do you have Gas heat or Electric heat For Heat Pump systems Change over valve or reversing valve type D...

Страница 3: ... system compressor in test mode Disconnect Y1 or Y2 outputs if using test mode on a live system System Settings Submenu Sets the HVAC operational settings below Mechanical Settings Submenu Sets HVAC system type and configuration Type Range Gas Elec or Heat pump Default Gas Elec Selects HVAC type Gas Electric or Heat pump Fan Type Range Gas or Elec Default Gas Selects the Fan type if system is Gas ...

Страница 4: ...ge 2 Heating Delta Stage 3 ON Range 1 to 8 degrees Default 3 Sets the delta from setpoint that stage 3 heating starts Heating Delta Stage 3 OFF Range 0 to 8 degrees Default 0 Sets the delta from setpoint that stage 3 heating stops Stage 3 turns off at setpoint Delta Stage 3 Cooling Delta Stage 1 ON Range 1 to 8 degrees Default 1 Sets the delta from setpoint that stage 1 cooling starts Cooling Delt...

Страница 5: ...iod followed by an Off period continuously Used to provide minimum air ventilation requirements When the Fan ON time is set to a value greater than 0 an additional Cycler FAN mode is present when pressing the FAN button Fan ON Time Range 0 120 minutes Default 0 OFF Fan OFF Time Range 10 120 minutes Default 10 Restore Defaults Range Yes No Default No Restores all settings to factory defaults Press ...

Страница 6: ... 1 On 1 8 1 Cool Delta Stage 1 Off 0 8 0 Cool Delta Stage 2 On 1 8 2 Cool Delta Stage 2 Off 0 8 0 Max Heat SP 40 109F 4 42C 90F Min Cool SP 44 113F 6 45C 60F Min Run Time 1 9 min 3 Min Off Time 1 9 min 5 Temp Response 1 6 2 Fan Cycler Submenu Fan Cycler ON time 0 120 min 0 0 Fan Cycler OFF Fan Cycler Off Time 10 120 min 10 Restore Defaults Yes or No No Exit no USER SETTINGS Filter Service Submenu ...

Страница 7: ...used for standard systems Ignore this setting 4 2nd Stage Heat Enable second stage heating outputs If you have a single stage heating system leave this set to N If you have a 2 stage heating system set to Y to enable 5 Aux Heat HP Not used for standard systems Ignore this setting 6 2nd Stage Cool Enable second stage cooling outputs If you have a single stage cooling system leave this set to N If y...

Страница 8: ...inal The setting of the C O Type will set the correct system operation For change over with cool systems Orange wire O terminal set C O type to w cool most common and default setting For change over with heat systems Brown wire B terminal set C O type to w heat 4 2nd Stage Heat Enable second stage heating outputs If you have a single stage heating system leave this set to N If you have a 2 stage h...

Отзывы: