Z-Wave T100R Скачать руководство пользователя страница 7

DCN: 140-01773-01

Page 7

Standard HVAC System

G   Fan 

W1 Heat Stage 1

Y1 Compressor Stage 1

R   24VAC  Return

C   24VAC Common

Thermostat Connection

Y2  Compressor Stage 2

W2 Heat Stage 2

Optional 24R Connection for single transformer HVAC Systems

RC and RH are jumpered together on thermostat board.

Cut RC/RH jumper JP1 for separate heating & cooling transformers

Y1

G

Y2

RS2

RS2

RSC

HC

Standard Gas/Electric HVAC System Wiring

Thermostat Setup:  
Standard Gas/Electric HVAC Systems

To set the HVAC system type, go to the 

Thermostat Info

screen 

and press

Setup

button 

1. 

Type.

   Set the HVAC System Type:  set to 

Gas/Elec

2. 

Fan Type

.  Set the HVAC Fan Type:

Set to 

Gas

for typical gas furnace (fan is controlled by the furnace)

Set to 

Elec

for electric heat  (fan call with heat call)

3. 

C/O type

. Not used for standard systems.  Ignore this setting.

4. 

2nd Stage Heat

.  Enable second stage heating outputs

If you have a single stage heating system, leave this set to 

N

If you have a 2 stage heating system, set to 

Y

to enable. 

5. 

Aux Heat (HP).

   Not used for standard systems.  Ignore this setting

6.  

2nd Stage Cool

.  Enable second stage cooling outputs

If you have a single stage cooling system, leave this set to 

N

.

If you have a two stage cooling system, set to 

Y

to enable.

24RC

W1

24RH

W2/O

RS1

RS1

RSC

H1

24C

Cooling 24V

Fan

Cooling stage 1

Cooling stage 2

Remote Sensor 2

Remote Sensor 2

Sensor shield

Humidity Relay Com 

24VAC Com

24V Heating

Heating stage 1

Heating stage 2

Remote Sensor 1

Remote Sensor 1

Sensor shield

Humidity Relay 

Remote Outside Sensor

Remote Indoor Sensor 

Shielded cable

Shielded cable

* Not used on this version
See Humidity enabled Product TZB45H 

Default Setup:

Gas/Elec

Gas Heat

1 Stage heating

1 Stage cooling

No setup required for 
this configuration

Thermostat back

*

*

Содержание T100R

Страница 1: ...System Wiring Terminal Marking Meaning Typical Wire Color Record the old thermostat wire connections and terminal marking here C 24VAC Common Blue R 24VAC Return Red G Fan Green W or W1 Heat stage 1 White Y or Y1 Cool stage 1 Yellow W2 Heat stage 2 Orange Y2 Cool stage 2 Black Heat Pump HVAC System Wiring Terminal Marking Meaning Typical Wire Color Record the old thermostat wire connections and te...

Страница 2: ...re the thermostat for the correct HVAC system type You will need to know the following information to correctly configure the thermostat The HVAC setup is in the Mechanical Settings menu screen HVAC system type What type HVAC system do you have Standard or Heat pump For Standard systems Fan Type Do you have Gas heat or Electric heat For Heat Pump systems Change over valve or reversing valve type D...

Страница 3: ... system compressor in test mode Disconnect Y1 or Y2 outputs if using test mode on a live system System Settings Submenu Sets the HVAC operational settings below Mechanical Settings Submenu Sets HVAC system type and configuration Type Range Gas Elec or Heat pump Default Gas Elec Selects HVAC type Gas Electric or Heat pump Fan Type Range Gas or Elec Default Gas Selects the Fan type if system is Gas ...

Страница 4: ...ge 2 Heating Delta Stage 3 ON Range 1 to 8 degrees Default 3 Sets the delta from setpoint that stage 3 heating starts Heating Delta Stage 3 OFF Range 0 to 8 degrees Default 0 Sets the delta from setpoint that stage 3 heating stops Stage 3 turns off at setpoint Delta Stage 3 Cooling Delta Stage 1 ON Range 1 to 8 degrees Default 1 Sets the delta from setpoint that stage 1 cooling starts Cooling Delt...

Страница 5: ...iod followed by an Off period continuously Used to provide minimum air ventilation requirements When the Fan ON time is set to a value greater than 0 an additional Cycler FAN mode is present when pressing the FAN button Fan ON Time Range 0 120 minutes Default 0 OFF Fan OFF Time Range 10 120 minutes Default 10 Restore Defaults Range Yes No Default No Restores all settings to factory defaults Press ...

Страница 6: ... 1 On 1 8 1 Cool Delta Stage 1 Off 0 8 0 Cool Delta Stage 2 On 1 8 2 Cool Delta Stage 2 Off 0 8 0 Max Heat SP 40 109F 4 42C 90F Min Cool SP 44 113F 6 45C 60F Min Run Time 1 9 min 3 Min Off Time 1 9 min 5 Temp Response 1 6 2 Fan Cycler Submenu Fan Cycler ON time 0 120 min 0 0 Fan Cycler OFF Fan Cycler Off Time 10 120 min 10 Restore Defaults Yes or No No Exit no USER SETTINGS Filter Service Submenu ...

Страница 7: ...used for standard systems Ignore this setting 4 2nd Stage Heat Enable second stage heating outputs If you have a single stage heating system leave this set to N If you have a 2 stage heating system set to Y to enable 5 Aux Heat HP Not used for standard systems Ignore this setting 6 2nd Stage Cool Enable second stage cooling outputs If you have a single stage cooling system leave this set to N If y...

Страница 8: ...inal The setting of the C O Type will set the correct system operation For change over with cool systems Orange wire O terminal set C O type to w cool most common and default setting For change over with heat systems Brown wire B terminal set C O type to w heat 4 2nd Stage Heat Enable second stage heating outputs If you have a single stage heating system leave this set to N If you have a 2 stage h...

Отзывы: