Z-Wave T100R Скачать руководство пользователя страница 6

DCN: 140-01773-01

Page 6

Installer Settings Summary

Setting

Range

Default

Display Lock

Y or N

N

Locks out front buttons

Service Mode Submenu

Test Mode

Y or N

N

Reduces delays for testing

System Settings Submenu

Mechanical Settings Submenu

Sys Type

Std or HP

Std

Fan Type

Gas or Elec

Gas

C/O Type

w/Heat or w/Cool

w/Cool

2

nd

Stage Heat

Y or N

N

Aux Heat

Y or N

Y

2

nd

Stage Cool

Y or N

N

H/C Delta

3 – 15 deg

3

Heat Delta Stage 1 On

1 – 8

1

Heat Delta Stage 1 Off

0 – 8

0

Heat Delta Stage 2 On

1 – 8

2

Heat Delta Stage 2 Off

0 – 8

0

Heat Delta Stage 3 On

1 – 8

3

Heat Delta Stage 3 Off

0 – 8

0

Cool Delta Stage 1 On

1 – 8

1

Cool Delta Stage 1 Off

0 – 8

0

Cool Delta Stage 2 On

1 – 8

2

Cool Delta Stage 2 Off

0 – 8

0

Max Heat SP

40-109F (4-42C)

90F

Min Cool SP

44-113F (6-45C)

60F

Min Run Time

1-9 min

3

Min Off Time

1-9 min

5

Temp Response

1-6

2

Fan Cycler Submenu

Fan Cycler ON time

0 – 120 min

0

0 = Fan Cycler OFF

Fan Cycler Off Time

10 – 120 min

10

Restore Defaults

Yes or No

No

Exit = no

USER SETTINGS

Filter Service Submenu

Service Interval

Disabled, 100-4000 hrs

300

Maint Service Submenu

Maint Interval

Disabled, 100-4000 hrs

3000

Screen Timeout (to minimized screen)

0, 20-120 sec

0

0 = off , will not timeout

F/C Mode

F or C 

F

Sensor Calibration Submenu

Internal -7 to +7

0

Backlite/Display Submenu

Backlight Timeout

0, 20-120

0

0 = backlite off

Backlight On Brightness

0-100%

100%

Backlight Off Brightness

0-100%

0%

Contrast

0-20

14

Содержание T100R

Страница 1: ...System Wiring Terminal Marking Meaning Typical Wire Color Record the old thermostat wire connections and terminal marking here C 24VAC Common Blue R 24VAC Return Red G Fan Green W or W1 Heat stage 1 White Y or Y1 Cool stage 1 Yellow W2 Heat stage 2 Orange Y2 Cool stage 2 Black Heat Pump HVAC System Wiring Terminal Marking Meaning Typical Wire Color Record the old thermostat wire connections and te...

Страница 2: ...re the thermostat for the correct HVAC system type You will need to know the following information to correctly configure the thermostat The HVAC setup is in the Mechanical Settings menu screen HVAC system type What type HVAC system do you have Standard or Heat pump For Standard systems Fan Type Do you have Gas heat or Electric heat For Heat Pump systems Change over valve or reversing valve type D...

Страница 3: ... system compressor in test mode Disconnect Y1 or Y2 outputs if using test mode on a live system System Settings Submenu Sets the HVAC operational settings below Mechanical Settings Submenu Sets HVAC system type and configuration Type Range Gas Elec or Heat pump Default Gas Elec Selects HVAC type Gas Electric or Heat pump Fan Type Range Gas or Elec Default Gas Selects the Fan type if system is Gas ...

Страница 4: ...ge 2 Heating Delta Stage 3 ON Range 1 to 8 degrees Default 3 Sets the delta from setpoint that stage 3 heating starts Heating Delta Stage 3 OFF Range 0 to 8 degrees Default 0 Sets the delta from setpoint that stage 3 heating stops Stage 3 turns off at setpoint Delta Stage 3 Cooling Delta Stage 1 ON Range 1 to 8 degrees Default 1 Sets the delta from setpoint that stage 1 cooling starts Cooling Delt...

Страница 5: ...iod followed by an Off period continuously Used to provide minimum air ventilation requirements When the Fan ON time is set to a value greater than 0 an additional Cycler FAN mode is present when pressing the FAN button Fan ON Time Range 0 120 minutes Default 0 OFF Fan OFF Time Range 10 120 minutes Default 10 Restore Defaults Range Yes No Default No Restores all settings to factory defaults Press ...

Страница 6: ... 1 On 1 8 1 Cool Delta Stage 1 Off 0 8 0 Cool Delta Stage 2 On 1 8 2 Cool Delta Stage 2 Off 0 8 0 Max Heat SP 40 109F 4 42C 90F Min Cool SP 44 113F 6 45C 60F Min Run Time 1 9 min 3 Min Off Time 1 9 min 5 Temp Response 1 6 2 Fan Cycler Submenu Fan Cycler ON time 0 120 min 0 0 Fan Cycler OFF Fan Cycler Off Time 10 120 min 10 Restore Defaults Yes or No No Exit no USER SETTINGS Filter Service Submenu ...

Страница 7: ...used for standard systems Ignore this setting 4 2nd Stage Heat Enable second stage heating outputs If you have a single stage heating system leave this set to N If you have a 2 stage heating system set to Y to enable 5 Aux Heat HP Not used for standard systems Ignore this setting 6 2nd Stage Cool Enable second stage cooling outputs If you have a single stage cooling system leave this set to N If y...

Страница 8: ...inal The setting of the C O Type will set the correct system operation For change over with cool systems Orange wire O terminal set C O type to w cool most common and default setting For change over with heat systems Brown wire B terminal set C O type to w heat 4 2nd Stage Heat Enable second stage heating outputs If you have a single stage heating system leave this set to N If you have a 2 stage h...

Отзывы: