Sets the minimum off time before another heating/cooling cycle can begin.  Provides 
compressor short cycle protection. 

Temp Response

Range: 1-6

Default: 2

Adjust the temperature sensor sensitivity.  Sets how fast the sensor responds to change.

Fan Cycler 

The fan cycler function cycles the HVAC system fan for an ON period followed by an Off 
period continuously.  Used to provide minimum air ventilation requirements.  When the Fan 
ON time is set to a value greater than 0, an additional “Cycler” FAN mode is present when 
pressing the FAN button.

Fan ON Time

Range: 0-120 minutes

Default: 0 (=OFF)

Fan OFF Time

Range: 10-120 minutes

Default: 10

Restore Defaults

Range: Yes, No

Default: No

Restores all settings to factory defaults.

Press Yes to restore defaults,
Press No to exit and not restore defaults

Relay Status

Display the status (on/off) of the thermostat output relays

Содержание T100R

Страница 1: ...System Wiring Terminal Marking Meaning Typical Wire Color Record the old thermostat wire connections and terminal marking here C 24VAC Common Blue R 24VAC Return Red G Fan Green W or W1 Heat stage 1 White Y or Y1 Cool stage 1 Yellow W2 Heat stage 2 Orange Y2 Cool stage 2 Black Heat Pump HVAC System Wiring Terminal Marking Meaning Typical Wire Color Record the old thermostat wire connections and te...

Страница 2: ...re the thermostat for the correct HVAC system type You will need to know the following information to correctly configure the thermostat The HVAC setup is in the Mechanical Settings menu screen HVAC system type What type HVAC system do you have Standard or Heat pump For Standard systems Fan Type Do you have Gas heat or Electric heat For Heat Pump systems Change over valve or reversing valve type D...

Страница 3: ... system compressor in test mode Disconnect Y1 or Y2 outputs if using test mode on a live system System Settings Submenu Sets the HVAC operational settings below Mechanical Settings Submenu Sets HVAC system type and configuration Type Range Gas Elec or Heat pump Default Gas Elec Selects HVAC type Gas Electric or Heat pump Fan Type Range Gas or Elec Default Gas Selects the Fan type if system is Gas ...

Страница 4: ...ge 2 Heating Delta Stage 3 ON Range 1 to 8 degrees Default 3 Sets the delta from setpoint that stage 3 heating starts Heating Delta Stage 3 OFF Range 0 to 8 degrees Default 0 Sets the delta from setpoint that stage 3 heating stops Stage 3 turns off at setpoint Delta Stage 3 Cooling Delta Stage 1 ON Range 1 to 8 degrees Default 1 Sets the delta from setpoint that stage 1 cooling starts Cooling Delt...

Страница 5: ...iod followed by an Off period continuously Used to provide minimum air ventilation requirements When the Fan ON time is set to a value greater than 0 an additional Cycler FAN mode is present when pressing the FAN button Fan ON Time Range 0 120 minutes Default 0 OFF Fan OFF Time Range 10 120 minutes Default 10 Restore Defaults Range Yes No Default No Restores all settings to factory defaults Press ...

Страница 6: ... 1 On 1 8 1 Cool Delta Stage 1 Off 0 8 0 Cool Delta Stage 2 On 1 8 2 Cool Delta Stage 2 Off 0 8 0 Max Heat SP 40 109F 4 42C 90F Min Cool SP 44 113F 6 45C 60F Min Run Time 1 9 min 3 Min Off Time 1 9 min 5 Temp Response 1 6 2 Fan Cycler Submenu Fan Cycler ON time 0 120 min 0 0 Fan Cycler OFF Fan Cycler Off Time 10 120 min 10 Restore Defaults Yes or No No Exit no USER SETTINGS Filter Service Submenu ...

Страница 7: ...used for standard systems Ignore this setting 4 2nd Stage Heat Enable second stage heating outputs If you have a single stage heating system leave this set to N If you have a 2 stage heating system set to Y to enable 5 Aux Heat HP Not used for standard systems Ignore this setting 6 2nd Stage Cool Enable second stage cooling outputs If you have a single stage cooling system leave this set to N If y...

Страница 8: ...inal The setting of the C O Type will set the correct system operation For change over with cool systems Orange wire O terminal set C O type to w cool most common and default setting For change over with heat systems Brown wire B terminal set C O type to w heat 4 2nd Stage Heat Enable second stage heating outputs If you have a single stage heating system leave this set to N If you have a 2 stage h...

Отзывы: