PG
10
HOLD
This will hold the target temperature you set indefinitely, until you turn
HOLD
off.
HOLD
will allow
you to operate your thermostat as a manual thermostat. It will keep whatever temperature you set until
you change it or cancel hold. Take care using the
HOLD
function as the program is now bypassed. To set
a hold target temperature, touch
HOLD
and use the +/- icons to select your hold temperature. The
HOLD
icon will display on the HOME screen indicating you have changed the Target Temperature. The system
will
HOLD
this temperature until you return to the manual screen and de-select
HOLD
by touching it. Hold
is also canceled when you set the mode to OFF.
HOLIDAY
This is a single program that repeats day after day until you turn it off. It supersedes the
weekly program. To use it touch
HOLIDAY
on the temporary screen. The default holiday program is
shown below. To modify this program, touch the PROGRAM button and then touch the DAY area until
HOLIDAY appears (after SAT). The default HOLIDAY program is set as 2 time slots; all day (same
target MORN, DAY and EVEN) and a different target for NITE. [Default program: HEAT 70
o
F all day
and 62
o
F at night. COOL 78
o
F all day and 82
o
F at night.]
EMER
(in HEAT PUMP type)
If you set your CT100 for HEAT PUMP with auxiliary heat, EMER function is available on the
MANUAL screen. If you touch EMER, it displays EMER|ON. Your HEAT PUMP is disabled and
auxiliary heat is your sole source of heat. This manual override stays active until you toggle EMER
off. Auxiliary heat is more expensive than the heat pump so use EMER only if the heat pump cannot
keep up or is defective.