INSTALLATION INSTRUCTIONS

69-1696EF

CT54 Thermostat

STEP 1. PREPARE FOR 

INSTALLATION

The CT54 Thermostat controls 2-wire, 15 Vac to 30 Vac, 
gas, oil or electric heating-only systems.

The CT54 Thermostat is not suitable for:
• cooling systems
• heating-cooling systems
• 3-wire electric heating systems

If you are unsure which thermostat model is right for your 
system, visit www.honeywell.com/yourhome or call 
Honeywell Customer Care at 1-800-468-1502.

1.

Check that the following components are included:

• Thermostat
• Two one-inch screws
• Installation Instructions

2.

Required tools:

• Slotted screwdriver
• Drill
• Drill bit (1/16 in.)
• Needle nose pliers
• Level
• Pencil

STEP 2. REMOVE OLD 

THERMOSTAT

1.

Turn power off to the system at the furnace or at 
the fuse/circuit breaker panel.

2.

If the cover does not easily pull off, remove any 
screws that may fasten the cover to the thermostat.

3.

Locate the heat anticipator scale and the heat 
anticipator lever on the old thermostat (see Fig. 1).

Fig. 1. Heat anticipator on old thermostat (example).

4.

Record the number that the heat 
anticipator lever points to on the heat 
anticipator scale.

NOTE: If you cannot find the heat anticipator setting on 

your thermostat, you can use a standard setting 
for your type of system when you reach 

Step 5. 

Set Heat Anticipator On New Thermostat.

5.

Remove the screw or screws that hold the thermo-
stat to the wall and pull the thermostat away from 
the wall.

6.

Remove the two wires from the old thermostat and 
wrap them around a pencil to keep them from fall-
ing back into the wall (see Fig. 2). If there are more 
than two wires connected to your old thermostat, 

do not remove the wires

. Visit www.honey-

well.com/yourhome or call 1-800-468-1502 for fur-
ther assistance with the installation.   

Fig. 2. Pull wires through wall opening.

M21192

OLD THERMOSTAT HEAT
ANTICIPATOR SCALE

HEAT ANTICIPATOR LEVER

TYPICAL LOCATION OF HEAT
ANTICIPATOR SCALE AND LEVER

WIRES 
THROUGH
WALL 
OPENING

M19645

Содержание CT54

Страница 1: ...that may fasten the cover to the thermostat 3 Locate the heat anticipator scale and the heat anticipator lever on the old thermostat see Fig 1 Fig 1 Heat anticipator on old thermostat example 4 Record the number that the heat anticipator lever points to on the heat anticipator scale NOTE If you cannot find the heat anticipator setting on your thermostat you can use a standard setting for your type...

Страница 2: ... the W terminal see Fig 4 and 5 4 Plug the hole in the wall with insulation to prevent a warm or cool draft from affecting the operation of the thermostat Fig 3 Remove cover on new thermostat Fig 4 R and W terminals on new thermostat Fig 5 Wraparound and straight wiring connections STEP 4 MOUNT NEW THERMOSTAT TO WALL 1 Position the thermostat on the wall Place a level on top of the thermostat and ...

Страница 3: ...ditional information go to www honeywell com your home or call Honeywell Customer Care at 1 800 468 1502 Before calling please have the following information available Thermostat model number and date code refer to Fig 6 for the location of the model number and date code Type of heating system for example gas or oil warm air hot water Heating System Heat Anticipator Setting Amps Hot Water 8 High E...

Страница 4: ...S A on recycled paper containing at least 10 post consumer paper fibers Automation and Control Solutions Honeywell International Inc Honeywell Limited Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley MN 55422 Scarborough Ontario M1V 4Z9 ...

Страница 5: ... toute vis qui retiendrait le couvercle au thermostat 3 Repérer l échelle de la résistance anticipatrice de chaleur et le doigt de réglage de la résistance anticipatrice de chaleur de l ancien thermostat voir la Fig 1 Fig 1 Résistance anticipatrice de l ancien thermostat exemple 4 Inscrire le chiffre vers lequel pointe le doigt de réglage de la résistance anticipatrice de chaleur REMARQUE S il est...

Страница 6: ... 5 4 Obstruer l ouverture dans le mur à l aide d isolant pour éviter qu un courant d air chaud ou froid ne nuise au fonctionnement du thermostat Fig 3 Retirer le couvercle du nouveau thermostat Fig 4 Bornes et R et W du nouveau thermostat Fig 5 Connexion droite et connexion enroulé ÉTAPE 4 INSTALLATION DU NOUVEAU THERMOSTAT AU MUR 1 Placer le thermostat sur le mur Placer un niveau sur le dessus du...

Страница 7: ...mposer le numéro d assistance sans frais de Honeywell 1 800 468 1502 Avant de composer assurez vous d avoir en main l information suivante Numéro de modèle du thermostat et code de date voir la Fig 6 pour savoir où trouver le numéro de modèle et le code de date Type de système de chauffage p ex gaz ou mazout air chaud eau chaude Systèmes de chauffage Réglage de la résistance anticipatrice de chale...

Страница 8: ...0 de fibres post consommation 69 1696EF J S 9 03 www honeywell com Solutions de régulation et d automatisation Honeywell International Inc Honeywell Limited Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley MN 55422 Scarborough Ontario M1V 4Z9 ...

Отзывы: