background image

74

01

70

_I

N

S

_I

nd

oo

r/

O

ut

do

or

 D

ig

ita

l T

he

rm

om

et

er

S

iz

e:

5”

W

x4

.7

5”

H

_O

ut

pu

t:1

00

%

_P

rin

ts

:1

/1

,B

lk 

Indoor/Outdoor 

Digital Thermometer

TEMPERATURE AND 

HUMIDITY AT A GLANCE

Содержание 740170

Страница 1: ...Indoor Outdoor Digital Thermometer TEMPERATURE AND HUMIDITY AT A GLANCE ...

Страница 2: ...ts and Controls 3 Battery Installation 5 Operation 5 Choosing In Out Temp Measurements 7 Temp and Humidity Alert Pre Settings 8 Setting Alerts 9 Max Min Temp Humidity Recording 10 Comfort Level Indication 10 Other Icons 11 Reset 11 Specifications 12 Warranty 13 ...

Страница 3: ... required size and type Do not mix old and new batteries different types of batteries or rechargeable batteries of different capacities Caution 1 The device should be used in the suggested operation environment DO NOT apply the device to extreme force shock high temperature water AC power or severe weather conditions 2 DO NOT attempt to dismantle the device s internal components There are no servi...

Страница 4: ...3 Location of parts and controls 1 LCD Screen 2 In Out Button 3 Alert Button 4 Max Min Button 5 Clear Button 6 Sensor Tip with Adhesive Pad and Screw hole 7 Sensor 7 1 2 3 4 5 6 ...

Страница 5: ...4 Location of parts and controls 1 Hanging Hole 2 Stand 3 Battery Compartment Cover 4 ºC ºF Switch 5 Battery Compartment 6 Sensor Wire Access 7 Sensor Jack 8 Buttons 9 Reset Button 1 9 8 6 2 4 5 7 3 ...

Страница 6: ...run it through the sensor access slot 3 Replace and slide the battery compartment door closed to secure Placing the sensor Finding a suitable location to mount the outdoor sensor improves the accuracy of readings and the reliability and durability of the device The ideal location would be on the north side of a building south side in the southern hemisphere 1 Remove the sensor tip from the sensor ...

Страница 7: ...ensor in a location where it will not be in direct sunlight and where it will have limited exposure to reflected sunlight Place the outdoor sensor at least 5 feet from man made sources of heat Place the outdoor sensor in a location at least 10 feet from lights and exhaust fans Keep the outdoor sensor and the cable at least 10 feet from 110V AC or 60Hz utility power Do not run the outdoor sensor ca...

Страница 8: ...ature is being displayed Press the IN OUT button to toggle between locations Note When testing temperatures lower than 58 F LL L will appear on the temperature display area when testing temperatures higher than 230 F HH H will be displayed As there is no humidity sensor for outdoor mode the indoor humidity will continue to appear on the humidity display area of the lower half of the screen in outd...

Страница 9: ...nd release the ALERT button The IN or OUT icon will flash on the display to indicate which pre setting is showing The pre setting will be presented in the following order Indoor High Temperature Indoor Low Temperature Indoor High Humidity Indoor Low Humidity Outdoor High Temperature Outdoor Low Temperature and then it reverts back to the normal test mode 8 ...

Страница 10: ...tivate or deactivate the alert mode The icon appears on the upper left of the LCD display when alert mode is currently activated Note You may also turn on the global alert mode by pressing the button while the unit is currently in alert mode icon is visible in the upper left of the LCD display 5 When alert mode is active and alert temperature and humidity are achieved an audible alert beep will so...

Страница 11: ...splay for 5 seconds then revert to current levels 4 Press the CLEAR button once to reset the records of the displaying MAX or MIN COMFORT LEVEL INDICATION The device will indicate the indoor COMFORT WET DRY level on the screen in the following situations Level Indicator Indoor Temp Range Indoor Humidity Range Comfort 68ºF 77ºF 20ºC 25ºC 40 RH 70 RH Wet At any temperature Over 70 RH Dry At any temp...

Страница 12: ...rrect humidity accordingly Relative humidity measurement will be affected by temperature 2 HH H IN or HH H OUT When the measured temperature is higher than 230 F these icons will appear in the temperature display area 3 LL L IN or LL L OUT When the measured temperature is lower than 58 F these icons will appear in the temperature display area 4 out This icon will appear in the temperature display ...

Страница 13: ...nge Indoor 32 F 122 F Outdoor 58 F 230 F Humidity Range Indoor 20 99 RH Outdoor N A Note Although the sensor can work within a wider temperature range of 58 F 230 F the LCD materials can work only within 32 F 122 F The above specifications are the results of comprehensive testing ...

Страница 14: ...ne s property When a store credit is given the original product must be returned to Brookstone and becomes Brookstone s property Obtaining Service To obtain warranty service call Brookstone Limited Warranty Service at 1 800 292 9819 Please be prepared to describe the product that needs service and the nature of the problem A purchase receipt is required All repairs and replacements must be authori...

Страница 15: ...on floor demonstration models and refurbished items or h a product that is used commercially or for a commercial purpose Brookstone SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM THE USE OF THIS PRODUCT OR ARISING OUT OF ANY BREACH OF THIS WARRANTY TO THE EXTENT PERMITTED BY APPLICABLE LAW BROOKSTONE DISCLAIMS ANY AND ALL STATUTORY OR IMPLIED WARRANTIES INCLUDING WITHOU...

Страница 16: ...740170 Find thousands more great ideas online Merrimack New Hampshire USA 03054 800 846 3000 Brookstone com ...

Отзывы: