![Z-Tec ZT4611 Скачать руководство пользователя страница 51](http://html1.mh-extra.com/html/z-tec/zt4611/zt4611_user-manual_3088212051.webp)
0004-000067
51
Process Variable
Type
Values
Description
StatusVolt mbbiDirect
000
16
to
FFF
16
Voltage status faults:
1 = latched event
ZT4210:
Bit 0 = input 1 overload
Bit 1 = input 2 overload
Bit 2 = input 3 overload (ZT4xx2)
Bit 3 = input 4 overload (ZT4xx2)
Bit 4 = input 1-2 overvoltage
Bit 5 = unused
Bit 6 = input 3-4 overvoltage (ZT4xx2)
Bit 7 = unused
Bit 8 = accessory 1 fault
Bit 9 = accessory 2 fault
Bit 10 = accessory 3 fault (ZT4xx2)
Bit 11 = accessory 4 fault (ZT4xx2)
ZT4400 & ZT4610
Bit 0 = input 1 overload
Bit 1 = input 2 overload
Bit 2 = input 3 overload (ZT4xx2)
Bit 3 = input 4 overload (ZT4xx2)
Bit 4 = input 1 overvoltage
Bit 5 = input 2 overvoltage
Bit 6 = input 3 overvoltage (ZT4xx2)
Bit 7 = input 4 overvoltage (ZT4xx2)
Bit 8 = accessory 1 fault
Bit 9 = accessory 2 fault
Bit 10 = accessory 3 fault (ZT4xx2)
Bit 11 = accessory 4 fault (ZT4xx2)