Users,  before  installing  and  commissioning,  shall  first  check 

whether the appearance of the product is good, and whether the 

variety  and  number  of  attachments  is  in  line  with  the  list  of 

accessories attached to the specifications. If there is any defect, 

please contact the supplier or manufacturer timely.

I. Open-package Checking

II. Schematic of each components and names of the whole machine

Medication 
cup

Medication 
cup

Power Switch

Power Switch

Air tube

Air tube

Power plug

Power plug

Filter cover

Main unit

Main unit

Holder

Holder

Air Outlet

Air Outlet

Figure 3: Schematic diagram of components (405A)

Figure 4: Schematic diagram of components (405B)

Figure 5: Schematic diagram of the nebulizer kit and accessories

Cap

Baffle

Mask

Medication

 

cup

Mouthpiece

Air

 

tube

Содержание 405A

Страница 1: ...al closely JIANGSU YUYUE MEDICAL EQUIPMENT SUPPLY CO LTD Sales Center Address Huanyuan East Road No 1 Xuzhuang Software Park Nanjing Jiangsu Province P R China 210000 Manufacturing Address YunYang Ind...

Страница 2: ...intenance 03 III Sale and others 19 01 Contents 1 Power Input AC100 240V 350mA 50 60Hz Output DC12V 1000mA 2 Maximum nebulization rate 0 2mL min 3 MMD 3 9 m Percentage of nebulized particles with diam...

Страница 3: ...transportation 02 03 1 The pressure source is DC compression pump 2 Innovative designs simple operation compacted size easy storage and portable 3 Schematic diagram of working principles The compresse...

Страница 4: ...or manufacturer timely I Open package Checking II Schematic of each components and names of the whole machine Medication cup Medication cup Power Switch Power Switch Air tube Air tube Power plug Powe...

Страница 5: ...the scale on your syringe or vial for accurate measurement of 2 Add the correct amount of prescribed medication to the medication cup III Preparing the Nebulizer for Use medication After the medicatio...

Страница 6: ...ect the air tube to the connector of the main unit and the medication cup respectively 1 Connect one end to the main unit connector 2 Connect the other end to the medication cup connector So far prepa...

Страница 7: ...zer mask and do not let the medication left in the face Rotating the cap can properly adjust aerosol quantity 3 Hold the nebulizer kit for treatment 1 Cleaning Following cleaning instructions after ea...

Страница 8: ...the disinfectant manufacturer a Disinfectant soaking should be in accordance with the time required in the instruction manual of disinfectant Rinse with clean warm water and allow to air dry in a cle...

Страница 9: ...e filter Remove the old filter sheet with a toothpick or other tools and then install a new one 3 Install the cover of filter sheet Caution Before use make sure the filter sheet is properly installed...

Страница 10: ...is and Troubleshooting Symbol Meaning Type II device Symbol Meaning Type B application No Symptom Analysis 1 The device is abnormally loud The air filter cover is incorrectly attached Power is not on...

Страница 11: ...his description are for proper and safe use of the product and the prevention of harm to the user or others or damages Warnings and notes are in the following For patients in coma or sputum patients p...

Страница 12: ...ipe off the liquid with gauze or other soft absorbent material I Sale 1 If there is any quality problem caused by non human factors within one week from the date of sale the company is responsible for...

Страница 13: ...ltage power supply network The processing of discarded main unit accessories and other products should be in accordance with the provisions of the local government Inform 1 For machine damages and fai...

Отзывы: