6.3 Hydraulic fluid 

 

6.3.1 Fluid type

 

Petroleum base oil: Use a fluid equivalent to ISO VG32 or 46. 
Synthetic fluid: Use a phosphate ester or polyol ester fluid. 

When phosphate ester fluids are used, prefix “F-” to the model number 
because the special seals (fluororubber) are required to be used. 

(Note) For use with hydraulic fluids other than those listed above, consult us 

separately. 

 

6.3.2 Fluid viscosity and temperature 

Meet the following requirements for fluid viscosity and temperature during operation. 
- Viscosity: 15 to 400 mm

2

/s 

- Fluid temperature: - 15 to 60 ºC 
Note that the recommended fluid temperature ranges from 40 to 50 ºC. 

 

6.3.3 Control of contamination 

Contamination of hydraulic fluid with foreign matter often affects the proper operation of 
the valve.    Keep hydraulic fluid clean and use a line filter.    To ensure a longer service 
life of the valve, improving hydraulic fluid cleanliness is recommended. 
 

Contamination Level 

NAS 1638 Class 10 

ISO 4406 21/19/15 

 
 

Never use contaminated fluid. 
Doing so may result in malfunction or failure of the valve.

 

 

7. Maintenance

 

 

 The service life of the O-rings is about two or three years depending on the condition of 

valve operation.  Please keep spare O-rings handy for replacement in the event of fluid 
leakage. 

 

 The components and performance of the valve deteriorate as the duration of service 

increases or depending on the operating conditions.  To keep the valve in working order 
and prevent unexpected failure of hydraulic equipment, inspecting the valve regularly is 
recommended.    The recommended inspection interval is at least two to three years.    The 
valve deterioration conditions depend on the operating conditions of hydraulic equipment 
and the fluid contamination level.  Thus, performing regular inspection depending on the 
situation is recommended.    For periodic maintenance, contact our customer support. 

 

  Contamination of hydraulic fluid with foreign matter often affects the proper operation of the 

valve.    It may cause failure or shorten the valve’s service life.    Keep hydraulic fluid clean 
(contamination level: NAS class 10/ISO 4406 21/19/15 or better).    Also, use a line filter and 
inspect/clean it regularly. 

 

 Petroleum base oil containing water shortens the valve’s service life.    To avoid this situation, 

inspect the fluid regularly. 

 

  Air entry into the circuit may impair the proper operation of the valve.    Bleed air completely 

from the circuit. 

CAUTION

Содержание ELDFG-01EH 10 Series

Страница 1: ...read this manual thoroughly before use Be sure to follow the instructions described in the Safety Precautions section of this manual Keep this manual at hand for future reference When creating instru...

Страница 2: ...made to the product Although this manual has been prepared with great care please contact the place of purchase or our customer support if you find any ambiguous explanations errors or omissions If t...

Страница 3: ...ng the main body of this manual Symbols and definitions for safety precautions in this manual are as follows Symbols and definitions for safety precautions in this manual are as follows Ignoring safet...

Страница 4: ...he instructions for the connector For the use of YUKEN s connector TK290457 1 see the Wiring section of this manual Never touch the connector while the power is on Doing so may cause electric shock re...

Страница 5: ...e dimensions 11 3 2 Required tools 11 3 3 Check of the valve mounting surface 11 3 4 Mounting position 11 3 5 Installation 12 4 Wiring 4 1 Recommended cable 13 4 2 Connection between the cable and the...

Страница 6: ...type 3C2L is suitable for position control 2 overlap 1 3 Product check Check the following points upon delivery of the product If any questions or problems arise please contact the place of purchase...

Страница 7: ...lectric Connection 6 PE Connector 1 Use the valves so that the relationship between the valve pressure difference and the flow rate as specified in Range of flow control on page 7 is met 2 This value...

Страница 8: ...nge of flow control Control Method 4 Way Valve Control Method 3 Way Valve Valve Pres Diff MPa Valve Pres Diff MPa Valve Pres Diff MPa Valve Pres Diff MPa Flow Rate L min Flow Rate L min Flow Rate L mi...

Страница 9: ...n below Basically the dimensions of the mounting surface conform to ISO 4401 03 02 0 94 The mounting surface should have a good machined finish e g surface roughness of 6 S Indicator Lamp Cylinder Por...

Страница 10: ...ace as shown below Basically the dimensions of the mounting surface conform to ISO 4401 05 04 0 94 The mounting surface should have a good machined finish e g surface roughness of 6 S Indicator Lamp C...

Страница 11: ...e recommended load resistance is 200 Fail Safe Function 1 Model Number Spool Position Function Graphic Symbols F ELDFG EH 3C2 XY C Neutral All Ports Blocked F ELDFG EH 3C2L XY C Neutral or or F ELDFG...

Страница 12: ...Number Tool Name Use ELDFG 01EH Hexagon Wrench Width Across Flats 4 mm For M5 Valve Mounting Bolts ELDFG 03EH Hexagon Wrench Width Across Flats 5 mm For M6 Valve Mounting Bolts ELDFG EH Phillips Screw...

Страница 13: ...FG 03EH M6 35L 13 16 Nm For valve installation use the specified number of bolts and apply the specified tightening torque Failure to do so may cause damage to the bolts or outflow of hydraulic fluid...

Страница 14: ...yvinyl chloride insulated flexible cords for microphone shielded MVVS or the equivalent JIS C 3306 Polyvinyl chloride insulated flexible cords shielded VCTF or the equivalent JIS C 3401 Control cables...

Страница 15: ...lead wire size is 1 0 mm2 AWG17 or less c Terminate the end of the cable as shown below Peel off the length of the cable sheath and the ends of the lead wires as shown above 2 Wiring a Pass the cable...

Страница 16: ...stment range is about 15 Indicator Lamp Power Supply Green Lights up when the valve is powered on Deviation Alarm Red Lights up when the spool travel deviates about 3 or more from the input value and...

Страница 17: ...t noise such as inserting a noise filter on the power supply side Do not share the AC power source to the DC power supply with high noise generating equipment solenoid operated directional valves heat...

Страница 18: ...the following items 1 When the power indicator LED green does not light up Check the power supply voltage Check the power supply side if no voltage is present 2 When the deviation alarm LED red light...

Страница 19: ...lic fluid resulting in unstable valve operation and or solenoid failure Do not connect the tank port to any line that generates a surge pressure Doing so may cause malfunction or failure of the valve...

Страница 20: ...rings is about two or three years depending on the condition of valve operation Please keep spare O rings handy for replacement in the event of fluid leakage The components and performance of the valv...

Страница 21: ...valve as general industrial waste 10 Customer service If there are requests regarding our products or if any services are required please contact the place of purchase our customer support or the foll...

Отзывы: